- Guías de estudio, Notas de estudios & Resúmenes

¿Buscas las mejores guías de estudio, notas de estudio y resúmenes para ? En esta página encontrarás 4 documentos de estudio para .

All 4 resultados

Ordenador por:

NICET Inspect & Test LVL 2 Exam Questions   And Well Elaborated Solutions |Verified 100%  Correct|
  • Examen

    NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions |Verified 100% Correct|

  • NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions |Verified 100% Correct| According to NFPA 72, cellular transmission is a performance based technology and as such _____? A. Requires AHJ approval B. Requires the use of a DACT C. Requires a secondary means of transmission D. Does not require a secondary communications path - answer -D. Does not require a secondary communications path NFPA 72 26.6.3.3 Consider the installatio...
  • TopGradeGuru
    $9.49 Más información
NICET Inspect & Test LVL 2 Exam Questions  And Well Elaborated Solutions
  • Examen

    NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions

  • NICET Inspect & Test LVL 2 Exam Questions And Well Elaborated Solutions Consider a smoke control system with a stairwell pressurization system. A _____ shall be provided in the air supply to the pressurized stairwell. A. Supervisory switch to monitor fan operation B. Manual fire alarm box C. Heat detector D. Smoke detector - answer -D. Smoke Detector NFPA 92 - 6.4.6.2.1 NFPA 72 states that smoke detector spacing shall be reduced where the airflow in a defined space exceeds _____ air...
  • TheExamMaestro
    $8.29 Más información
NICET INSPECT & TEST LVL 2
  • Examen

    NICET INSPECT & TEST LVL 2

  • While testing a fire alarm system at a correctional facility, it is determined that the general fire alarm signal requires human intervention to be initiated. This is permitted using a _____ feature? A. Pre signal B. Positive alarm sequence C. Manual initiation D. Alarm verification - Answer-A. Pre Signal NFPA 72 23.8.1.1.2(3)(a) Consider a 50′ x 50′ room with a 12′ ceiling. What is the minimum intensity required for a ceiling mount strobe? A. 85 cd B. 110 cd C. 80 cd D. ...
  • Greaterheights
    $10.99 Más información
¿Miedo a perderte algo? Pues no lo hagas.
¿Te preguntas por qué tantos estudiantes llevan ropa bonita, tienen dinero de sobra y disfrutan de toneladas de tiempo libre? ¡Pues se venden en Stuvia! Imagina que tus apuntes de estudio se descargan una docena de veces por 15 euros cada uno. Todos. Los. Dias.