- Guías de estudio, Notas de estudios & Resúmenes
¿Buscas las mejores guías de estudio, notas de estudio y resúmenes para ? En esta página encontrarás 89 documentos de estudio para .
89 resultados
Examen
IDFX Exam Questions and Correct Answers
IDFX Exam Questions and Correct Answers 
Workstation panels of 69"H or greater create a corridor and will require a 44" wide aisle 
- Answer-One side of a path is defined by a full-height wall and the other side is defined by workstation panels. Why would the designer measure the height of the workstation panels? 
 
Workstation panels of 62"H or greater create a corridor and will require a 36" wide aisle Workstation panels of 62"H or greater create a corridor and will require a 44" wide ai...
Examen
IDFX Exam Questions and Answers All Correct
IDFX Exam Questions and Answers All Correct 
Accessible Toilet Floor Space - Answer-Require an unobstructed 60" turning circle. 
 
Grab Bars-Mounting Height - Answer-33"-36" AFF. 
 
Grab BARS- Side of Toliets - Answer-Must be 42"L. 
 
Grab Bars-Behind Toilets. - Answer-Must be 36"L. 
 
Clearance Around Accessible Toilets. - Answer-Must be 60" along rear wall and 56" along side wall. 
 
Accessible Shower size - Answer-30 x 60 Minimum 
 
Clear Floor Space Bathrooms - Answer-Must be 30 x 48 ...
Examen
IDFX 2023 Exam Questions with Correct Answers
IDFX 2023 Exam Questions with Correct Answers 
IIC - Impact Isolation Class - Answer-A single number rating of a floor/ceilings impact sound performance. The higher the rating, the better the floor performs in reducing impact sounds 
 
Reference Standard Specification - Answer-A variation of the descriptive specification type that describes a material, product, or process based on requirements set by an accepted authority or test method. 
 
Pure Performance Specification - Answer-A statement set...
Examen
IDFX 2023 Exam Questions with All Correct Answers
IDFX 2023 Exam Questions with All Correct Answers 
What type of plan is always needed to begin space planning in an existing building? - Answer-Base plan 
 
For most planning problems, the most efficient type of circulation system is what? - Answer-double loaded corridor 
 
What is needed to determine rentable floor area? - Answer-net assignable area, efficiency factor, rentable-usable ratio 
What is the net area or net assignable area of a building? - Answer-It is the space a client needs for t...
Examen
IDFX Study Test Questions with Correct Answers
IDFX Study Test Questions with Correct Answers 
Programming - Answer-A process during which information about a problem is collected, analyzed, and clearly stated to provide a basis for design 
 
The Five Step Process - Answer-establishing goals, collecting/analyzing facts, uncovering and testing concepts, determining needs, stating the problem 
 
Programmatic concepts - Answer-performance requirement related to methods of solving a problem or satisfying a need. 
 
human factors - Answer-the cor...
Examen
IDFX Exam Questions and Answers All Correct
IDFX Exam Questions and Answers All Correct 
Accessible Toilet Floor Space - Answer-Require an unobstructed 60" turning circle. 
 
Grab Bars-Mounting Height - Answer-33"-36" AFF. 
 
Grab BARS- Side of Toliets - Answer-Must be 42"L. 
 
Grab Bars-Behind Toilets. - Answer-Must be 36"L. 
 
Clearance Around Accessible Toilets. - Answer-Must be 60" along rear wall and 56" along side wall. 
 
Accessible Shower size - Answer-30 x 60 Minimum 
 
Clear Floor Space Bathrooms - Answer-Must be 30 x 48...
Examen
IDFX 2023 Exam Questions with All Correct Answers
IDFX 2023 Exam Questions with All Correct Answers 
What type of plan is always needed to begin space planning in an existing building? - Answer-Base plan 
 
For most planning problems, the most efficient type of circulation system is what? - Answer-double loaded corridor 
 
What is needed to determine rentable floor area? - Answer-net assignable area, efficiency factor, rentable-usable ratio 
 
What is the net area or net assignable area of a building? - Answer-It is the space a client needs fo...
Examen
IDFX Practice Test Questions with Correct Answers
IDFX Practice Test Questions with Correct Answers 
Green Globes - Answer-assessment run by Green Building Initiative 
 
Building Green - Answer-Publisher of Environmental Building News and the GreenSpec directory 
 
Greenguard Certification Program - Answer-tests products for emissions 
 
Greenguard Environmental Institute - Answer-Provides list of products with allowable emissions levels. Acquired by UL Environment 
 
Green Label Plus - Answer-tests carpets, cushions, adhesives for VOCs, styre...
Examen
IDFX Exam Questions and Correct Answers
IDFX Exam Questions and Correct Answers 
Workstation panels of 69"H or greater create a corridor and will require a 44" wide aisle - Answer-One side of a path is defined by a full-height wall and the other side is defined by workstation panels. Why would the designer measure the height of the workstation panels? 
 
Workstation panels of 62"H or greater create a corridor and will require a 36" wide aisle 
Workstation panels of 62"H or greater create a corridor and will require a 44" wide a...
Examen
IDFX 2023 Exam Questions with Correct Answers
IDFX 2023 Exam Questions with Correct Answers 
IIC - Impact Isolation Class - Answer-A single number rating of a floor/ceilings impact sound performance. The higher the rating, the better the floor performs in reducing impact sounds 
 
Reference Standard Specification - Answer-A variation of the descriptive specification type that describes a material, product, or process based on requirements set by an accepted authority or test method. 
 
Pure Performance Specification - Answer-A statement se...
Examen
IDFX Exam Questions with Correct Answers
IDFX Exam Questions with Correct Answers 
The minimum clear width for an accessible route is __ continuously and __ at a passage point such as a doorway. - Answer-36", 32" 
 
The minimum passage width for two wheelchairs is ___. - Answer-60" 
 
the minimum clear floor space required to accommodate one stationary wheelchair is _____. - Answer-30" x 48" 
 
An accessible route may have a slope of ___. - Answer-1:20 or 5% 
 
A door must have a minimum clear opening width of __ when opened at 9...
Examen
IDFX Practice Test I Verified Questions And Answers 2023/2024
IDFX Practice Test I Verified Questions And Answers 2023/2024 
 
IDFX Practice Test I Verified Questions And Answers 2023/2024
Examen
IDFX Sample Exam Questions And Answers With Verified Study Solutions 2023/2024
IDFX Sample Exam Questions And Answers With Verified Study Solutions 2023/2024
Examen
IDFX Sample Exam Questions And Answers With Verified Study Set
IDFX Sample Exam Questions And Answers With Verified Study Set
Examen
IDFX Practice Test II Questions And Answers With Complete Solutions
IDFX Practice Test II Questions And Answers With Complete Solutions
Lote
Interior Design Fundamentals Exam (IDFX) Tests Bundle Set
Interior Design Fundamentals Exam (IDFX) Tests Bundle Set
Examen
IDFX – Codes questions with correct answers
max door threshold cant exceed __ in height Answer 1/2" 
 
door opening force cant be more than __ ft lb Answer 5 ft lb 
 
Door clearances: 
 
Hinge approach, pull side (A) Answer 54" min depth, 42" min space by strike jamb 
 
60" min depth, 36" min space by strike jamb 
 
Front Approach, Pull Side Answer 60" min depth, 18" min space by strike jamb 
 
front approach, push side Answer 48" min depth, 0" min space by strike jamb 
 
hinge approach, push side Answer 42" min depth, 22" min ...
Examen
NCIDQ- IDFX-Programming and Site Analysis questions with correct answers
1. it cannot address why people are behaving the way they are. 
2. it is only valid for a period of time. 
it is accurate only when implemented by a skilled practitioner. Answer In terms of the programming process, what are three limitations of behavior observation as a technique for gathering information? 
 
1. Client Interviews 
2. Field Surveys 
3. Observation 
4. Questionnaires Answer What four methods of gathering information are used in the programming process? 
 
Multiply the area requir...
Examen
NCIDQ-IDFX questions with correct answers
Which electrical outlets in a kitchen with an island and second prep sink must be GFI? Answer all within 36" of the prep sink and any other water sources 
 
In regards to means of egress, the travel distance is? Answer the measurement of the distance between the most remote occupiable point of an area or room to the entrance of the nearest exit that serves it. It is part of the exit access and measured in a straight line along the path of egress travel 
 
Dead-end corridors must not exceed: Ans...
Examen
IDFX questions with correct answers
What type of plan is always needed to begin space planning in an existing building? Answer Base plan 
 
For most planning problems, the most efficient type of circulation system is what? Answer double loaded corridor 
 
What is needed to determine rentable floor area? Answer net assignable area, efficiency factor, rentable-usable ratio 
 
What is the net area or net assignable area of a building? Answer It is the space a client needs for their specific program functions like offices, work rooms ...