National Electrical Code (NEC) 9th Edition – 2025/2026 Study Guide This guide is designed to test key concepts from the National Electrical Code with an emphasis on foundational rules, calculations, and safety principles. The answers are illustrated in the specified format. Disclaimer: This guide is based on the NEC and its enduring principles. For the most current code, always refer to the latest officially adopted edition (NFPA 70) and consult with your local Authority Having Jurisdiction (AHJ). Chapter 1: General & Definitions 1. What is the primary purpose of the National Electrical Code?  ANSWER The primary purpose of the NEC is the practical safeguarding of persons and property from hazards arising from the use of electricity. 2. What does the NEC consider a "Qualified Person"?  ANSWER A qualified person is one who has skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the hazards involved. 3. Are the NEC requirements intended to be applied retroactively to existing installations?  ANSWER No, the NEC is generally not retroactive unless an existing installation is specifically modified, repaired, or renovated, at which point the new rules apply to the work performed. 4. What is the definition of an "Accessible (as applied to wiring methods)"?  ANSWER Accessible means capable of being reached without removing building finishes, structures, or permanent barriers, and is not permanently closed in by such elements. 5. What is the definition of an "Readily Accessible"?  ANSWER Readily accessible means capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is requisite to climb over or remove obstacles or use portable ladders, etc. Chapter 2: Wiring & Protection (Article 100, 200, 210, 215, 220) 6. What is the minimum general lighting load calculation for a dwelling unit, in volt-amperes per square foot?  ANSWER The minimum general lighting load for dwelling units is 3 volt-amperes per square foot, calculated from the outside dimensions. 7. How many 125-volt, 15- or 20-ampere receptacle outlets are required in a dwelling unit kitchen countertop?  ANSWER A receptacle outlet must be installed at every kitchen countertop space 12 inches or wider. Countertops separated by range tops, sinks, or appliances are considered separate spaces. All countertop receptacles must be within 24 inches of the countertop's edge. 8. What is the minimum branch-circuit rating for a single receptacle on an individual branch circuit?  ANSWER The branch-circuit rating must not be less than the rating of the single receptacle. A single 50-ampere receptacle requires a minimum 50-ampere branch circuit. 9. What is the required minimum size for equipment grounding conductors (EGCs) of branch circuits?  ANSWER The minimum size is based on the rating of the overcurrent device. For a 20-ampere circuit, the minimum copper EGC is 12 AWG. For a 60-ampere circuit, it is 10 AWG. (Refer to NEC Table 250.122). 10. How many 20-ampere small-appliance branch circuits are required for the kitchen and dining areas of a dwelling?  ANSWER At least two 20-ampere small-appliance branch circuits are required to supply receptacle outlets in the kitchen, pantry, breakfast room, dining room, and similar areas. 11. What is the NEC requirement for "AFCI" protection in dwelling unit bedrooms?  ANSWER Arc-Fault Circuit Interrupter (AFCI) protection is required for all 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets in dwelling unit bedrooms, living rooms, dining rooms, and other specific living areas. 12. What is the NEC requirement for "GFCI" protection for bathrooms?  ANSWER Ground-Fault Circuit Interrupter (GFCI) protection is required for all 125- volt, 15- and 20-ampere receptacles installed in bathrooms. 13. What is the required working space depth in front of a 480V panelboard with exposed live parts on one side and grounded metal on the other?  ANSWER For Condition 2 (exposed on one side, grounded on the other), the minimum required working space depth is 3.5 feet for systems 301V-1kV. (Refer to NEC Table 110.26(A)(1)). 14. How is the feeder or service load calculated for a residential electric clothes dryer?  ANSWER The load for a household electric clothes dryer is 5000 watts (or the nameplate rating, whichever is larger) per dryer. For four or more dryers, a demand factor can be applied. 15. What is the minimum headroom for working spaces about service equipment, switchboards, or panelboards?  ANSWER The minimum headroom is 6.5 feet. The width must be at least 30 inches or the width of the equipment, whichever is greater. 16. Where is a "Main Disconnecting Means" required for a service?  ANSWER Each service must have a main disconnecting means, and it must be located at a readily accessible location either outside or inside the building, nearest the point of entrance of the service conductors.

Mostrar más Leer menos
Institución
National Electrical Code 9th Edition
Grado
National Electrical Code 9th Edition










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
National Electrical Code 9th Edition
Grado
National Electrical Code 9th Edition

Información del documento

Subido en
27 de diciembre de 2025
Número de páginas
17
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

National Electrical Code (NEC) 9th Edition – 2025/2026 Study
Guide
This guide is designed to test key concepts from the National Electrical Code with an
emphasis on foundational rules, calculations, and safety principles. The answers are
illustrated in the specified format.

Disclaimer: This guide is based on the NEC and its enduring principles. For the most
current code, always refer to the latest officially adopted edition (NFPA 70) and consult
with your local Authority Having Jurisdiction (AHJ).




Chapter 1: General & Definitions

1. What is the primary purpose of the National Electrical Code?

 ANSWER ✓ The primary purpose of the NEC is the practical safeguarding of persons
and property from hazards arising from the use of electricity.

2. What does the NEC consider a "Qualified Person"?

 ANSWER ✓ A qualified person is one who has skills and knowledge related to the
construction and operation of the electrical equipment and installations and has
received safety training to recognize and avoid the hazards involved.

3. Are the NEC requirements intended to be applied retroactively to existing
installations?

 ANSWER ✓ No, the NEC is generally not retroactive unless an existing installation is
specifically modified, repaired, or renovated, at which point the new rules apply to the
work performed.

4. What is the definition of an "Accessible (as applied to wiring methods)"?

 ANSWER ✓ Accessible means capable of being reached without removing building
finishes, structures, or permanent barriers, and is not permanently closed in by such
elements.

, 5. What is the definition of an "Readily Accessible"?

 ANSWER ✓ Readily accessible means capable of being reached quickly for operation,
renewal, or inspections without requiring those to whom ready access is requisite to
climb over or remove obstacles or use portable ladders, etc.




Chapter 2: Wiring & Protection (Article 100, 200, 210, 215, 220)

6. What is the minimum general lighting load calculation for a dwelling unit, in
volt-amperes per square foot?

 ANSWER ✓ The minimum general lighting load for dwelling units is 3 volt-amperes
per square foot, calculated from the outside dimensions.

7. How many 125-volt, 15- or 20-ampere receptacle outlets are required in a
dwelling unit kitchen countertop?

 ANSWER ✓ A receptacle outlet must be installed at every kitchen countertop space 12
inches or wider. Countertops separated by range tops, sinks, or appliances are
considered separate spaces. All countertop receptacles must be within 24 inches of the
countertop's edge.

8. What is the minimum branch-circuit rating for a single receptacle on an
individual branch circuit?

 ANSWER ✓ The branch-circuit rating must not be less than the rating of the single
receptacle. A single 50-ampere receptacle requires a minimum 50-ampere branch
circuit.

9. What is the required minimum size for equipment grounding conductors (EGCs)
of branch circuits?

 ANSWER ✓ The minimum size is based on the rating of the overcurrent device. For a
20-ampere circuit, the minimum copper EGC is 12 AWG. For a 60-ampere circuit, it is 10
AWG. (Refer to NEC Table 250.122).

10. How many 20-ampere small-appliance branch circuits are required for the
kitchen and dining areas of a dwelling?

,  ANSWER ✓ At least two 20-ampere small-appliance branch circuits are required to
supply receptacle outlets in the kitchen, pantry, breakfast room, dining room, and similar
areas.

11. What is the NEC requirement for "AFCI" protection in dwelling unit bedrooms?

 ANSWER ✓ Arc-Fault Circuit Interrupter (AFCI) protection is required for all 120-volt,
single-phase, 15- and 20-ampere branch circuits supplying outlets in dwelling unit
bedrooms, living rooms, dining rooms, and other specific living areas.

12. What is the NEC requirement for "GFCI" protection for bathrooms?

 ANSWER ✓ Ground-Fault Circuit Interrupter (GFCI) protection is required for all 125-
volt, 15- and 20-ampere receptacles installed in bathrooms.

13. What is the required working space depth in front of a 480V panelboard with
exposed live parts on one side and grounded metal on the other?

 ANSWER ✓ For Condition 2 (exposed on one side, grounded on the other), the
minimum required working space depth is 3.5 feet for systems 301V-1kV. (Refer to NEC
Table 110.26(A)(1)).

14. How is the feeder or service load calculated for a residential electric clothes
dryer?

 ANSWER ✓ The load for a household electric clothes dryer is 5000 watts (or the
nameplate rating, whichever is larger) per dryer. For four or more dryers, a demand
factor can be applied.

15. What is the minimum headroom for working spaces about service equipment,
switchboards, or panelboards?

 ANSWER ✓ The minimum headroom is 6.5 feet. The width must be at least 30 inches or
the width of the equipment, whichever is greater.

16. Where is a "Main Disconnecting Means" required for a service?

 ANSWER ✓ Each service must have a main disconnecting means, and it must be
located at a readily accessible location either outside or inside the building, nearest
the point of entrance of the service conductors.

17. What is the maximum number of disconnects allowed for a single service?
$14.39
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SmartscoreAaron Chicago State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
41
Miembro desde
1 año
Número de seguidores
3
Documentos
3245
Última venta
2 días hace
SMARTSCORES LIBRARY

Get top-tier academic support for Psychology, Nursing, Business, Engineering, HRM, Math, and more. Our team of professional tutors delivers high-quality homework, quiz, and exam assistance—ensuring scholarly excellence and grade-boosting results. Trust our collaborative expertise to help you succeed in any course at U.S.A Institutions.

3.8

4 reseñas

5
2
4
1
3
0
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes