100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

C.A. State Elevator Mechanic Study Guide | Questions With Complete Solutions

Puntuación
-
Vendido
-
Páginas
80
Grado
A+
Subido en
07-12-2025
Escrito en
2025/2026

C.A. State Elevator Mechanic Study Guide | Questions With Complete Solutions

Institución
Elevator Mechanic
Grado
Elevator mechanic











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Elevator mechanic
Grado
Elevator mechanic

Información del documento

Subido en
7 de diciembre de 2025
Número de páginas
80
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

C.A. State Elevator Mechanic Study
Guide | Questions With Complete
Solutions
Section 1: Safety Codes & ASME A17.1/CSA B44 (20 Questions)

1. What is the primary safety code governing elevator installation and maintenance in
California?
a) OSHA 1926
b) ASME A17.1/CSA B44 Safety Code for Elevators and Escalators
c) NFPA 70 (NEC)
d) CAL/OSHA Title 8

2. According to A17.1, what is the maximum allowable vertical distance that hoistway
doors can be out of plumb?
a) 1/4 inch in 3 feet
b) 1/8 inch in 3 feet
c) 1/2 inch in 5 feet
d) 1 inch in 10 feet

3. The minimum clearance between the car platform sill and the hoistway edge of the
landing sill must be:
a) 1/2 inch
b) 1/4 inch
c) 5/8 inch
d) 3/4 inch

4. What is the required stopping distance for a car safety device applying to the guide
rails during a governor tripping test?
a) It must stop within the shortest possible distance.
b) It must stop within the governor tripping speed marking.
c) It must not exceed 150% of the governor tripping speed.
d) It must stop within the distance determined by the code formula based on rated
speed and application.

5. A firefighter's service key switch, when operated, will cause the elevator to:
a) Shut down immediately.

, b) Return non-stop to the designated landing (typically main floor).
c) Run at inspection speed.
d) Bypass all door interlocks.

6. What is the purpose of a "broken rope switch" on a governor?
a) To detect slack rope condition
b) To detect overspeed
c) To detect underspeed
d) To detect rope wear

7. The emergency stop switch in the car must be what type of switch?
a) Momentary-contact, normally closed
b) Maintained-contact, manually opened and closed
c) A push-button that latches
d) A key-operated switch

8. Phase reversal protection is required on:
a) All AC and DC elevator drives.
b) Only AC single-phase machines.
c) AC wound-rotor and DC machines.
d) Only hydraulic elevators.

9. The minimum headroom in the hoistway above the top of the car crosshead must be:
a) The height of the car.
b) 3 feet for cars over 50 sq ft.
c) A distance per A17.1 Table 2.4.2.1 (e.g., 48" for speeds up to 200 fpm).
d) 6 feet for all elevators.

10. A pit ladder is required when the pit depth exceeds:
a) 36 inches
b) 48 inches
c) 60 inches
d) 72 inches

11. The maximum allowable vertical play in a guide-rail bracket fastening is:
a) 0.010 inches
b) 0.020 inches
c) 0.050 inches
d) 0.100 inches

,12. A device that prevents the car from moving unless the hoistway door is locked is called
a:
a) Door interlock
b) Door restrictor
c) Door clutch
d) Gate switch

13. The minimum number of steel ropes required for the suspension of a traction elevator
car is:
a) 2
b) 3
c) 4
d) 5

14. The governor rope diameter must be not less than:
a) 1/4 inch
b) 3/8 inch
c) 1/2 inch
d) 5/8 inch

15. What is the function of a "buffer" in an elevator system?
a) To stop a descending car or counterweight beyond its normal limit.
b) To absorb vibration from the machine.
c) To provide emergency lighting.
d) To lubricate the guide rails.

16. For a hydraulic elevator, the relief valve setting must not exceed what percentage of
the working pressure?
a) 110%
b) 125%
c) 150%
d) 200%

17. The car light switch must be located:
a) Inside the car on the panel.
b) In the machine room.
c) In the pit.
d) In each car and in the machine room.

, 18. A "bypass" switch for door interlocks is permitted for:
a) Normal passenger operation.
b) Inspection and maintenance operation only.
c) Firefighter's service.
d) Independent service.

19. The rated load of an elevator must be posted:
a) Only in the machine room.
b) Inside the car on the control panel.
c) In a conspicuous place inside the car.
d) On the hoistway door.

20. The minimum tension in a governor rope, when the car is at rest, should be sufficient
to cause the governor to operate at:
a) 50% of tripping speed.
b) 100% of tripping speed.
c) Its normal set speed under all conditions.
d) Twice the tripping speed.

Section 2: Electrical Theory & Components (20 Questions)

21. A device that converts electrical energy into mechanical rotation is a(n):
a) Generator
b) Motor
c) Encoder
d) Contactor

22. The purpose of a "Varistor" (MOV) in a control circuit is to:
a) Increase voltage.
b) Suppress voltage spikes and protect components.
c) Regulate current.
d) Store electrical charge.

23. In a three-phase AC induction motor, the rotor speed is:
a) Synchronous with the stator field.
b) Slightly less than synchronous speed (slip).
c) Greater than synchronous speed.
d) Unrelated to stator frequency.

24. A "contactor" is essentially a:
a) Solid-state relay.
$11.89
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TrustedExaminer Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
36
Miembro desde
11 meses
Número de seguidores
3
Documentos
2146
Última venta
1 día hace
A+ verified Examiner Hub

I provide professional academic writing and study support services for students who want results twice as fast. My expertise covers assignments, case studies, research papers, essays, discussions, and Q&A across a wide range of subjects and complexities. I take pride in delivering engaging, well-structured, and properly formatted work, always meeting deadlines and ensuring top-quality results tailored to your requirements. For every student you refer to me who places and pays for an order, I will complete one assignment for you free of charge. My passion lies in producing fresh, original content that not only meets academic standards but also impresses clients with clarity, depth, and creativity. I value punctuality, precision, and your satisfaction above all else. In addition, our store offers updated study materials, test banks, and guides for major courses such as Nursing, WGU, ACLS, USMLE, TNCC, PMHNP, ATI, and more. If you don’t find the document you need, we can fetch it for you within minutes. Please read descriptions carefully before purchasing, and don’t forget to leave a review to help us ensure 100% customer satisfaction. Subjects We Cover: Business Law Psychology Nursing Biology Chemistry Mathematics Physics Accounting & Finance Etc.....

Lee mas Leer menos
4.0

4 reseñas

5
1
4
2
3
1
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes