Through-Hole Technology - Answer -- The placement of any component on the
electronic assembly does not prevent the insertion or removal of any hardware (tool
clearance included) used to mount the assembly
- Bonding material is sufficient to hold the part but does not encapsulate and cover
component identification

Connection Mounting - Orientation - Answer -Inspection usually starts with a general
overall view of the electronic assembly, then follows each component/wire to its
connection, concentrating on the lead into the connection, the connection and the tail
end of the lead/wire leaving the connection. The wire/lead protrusion step for all lands
should be saved for last so that the board can be flipped over and all connections
checked together.

*Component Mounting - Orientation - Horizontal
Target - Class 1,2,3 - Answer -Nonpolarized components are oriented so that markings
are read the same way (left-to-right or top-to-bottom)

Component Mounting - Orientation - Vertical
Acceptable - Class 1,2,3 - Answer -- Polarized part is mounted with a long ground lead
- Nonpolarized component markings read from bottom to top

Component Mounting - Lead Forming
Defect - Class 1,2,3 - Answer -Lead is kinked

Component Mounting - Lead Forming - Space between Seal/Weld and Bend
Acceptable - Class 1,2,3 - Answer -Leads of through-hole mounted component extend
at least one diameter or thickness but not less than 0.8 mm [0.03 in] from the body,
solder bead, or lead weld

Component Mounting - Lead Forming - Space between Seal/Weld and Bend
Defect - Class 1,2,3 - Answer -Fractured lead weld, solder bead, or component body
lead seal

Component Mounting - Lead Forming - Stress Relief - Answer -- With camel hump
bends. Configuration incorporating a single camel hump may have the body positioned
off-center.
- Loop bends may be used if the location of the mounting holes prevents the use of a
standard bend if there is no possibility of shortening the lead to any adjacent component
lead or conductor. Use of loop bends may impact circuit impedance, etc., and shall be
approved by design engineering

Component Mounting - Lead Forming - Stress Relief

, Acceptable - Class 1,2,3 - Answer -- Component lead exiting component body is
approximately parallel to major body axis
- Component centering may be offset as a result of the type of stress relief bond

Component Mounting - Lead Forming - Stress Relief
Acceptable - Class 1
Process Indicator - Class 2
Defect - Class 3 - Answer -Lead bends less than one diameter or thickness but less
than 0.8mm [0.03 in] away from body seal

Component Mounting - Lead Forming - Damage
Acceptable - Class 1,2,3 - Answer -No nicks or deformation exceeding 10% of the
diameter, width or thickness of the lead

Component Mounting - Lead Forming - Damage
Defect - Class 1,2,3 - Answer -Heavy indentations such as serrated pliers mark

Component Mounting - Leads Crossing Conductors
Acceptable - Class 1,2,3 - Answer -- Sleeve does not interfere with formation of the
required solder connection
- Sleeve covers area of protection designated

Component Mounting - Leads Crossing Conductors
Not Established - Class 1
Defect - Class 2,3 - Answer -Splitting and/or unraveling of sleeving

Component Mounting - Leads Crossing Conductors
Defect - Class 2,3 - Answer -A component lead crossing an electrically noncommon
conductor violates minimum electrical clearance

Component Mounting - Hole Obstruction
Process Indicator - Class 2
Defect - Class 3 - Answer -Parts and components obstruct solder flow onto the primary
side (solder destination side) lands of plated through-holes required to be soldered

Component Mounting - DIP/SIP Devices and Sockets
Acceptable - Class 1,2,3 - Answer -Amount of tilt is limited by minimum lead protrusion
and height requirements

Component Mounting - DIP/SIP Devices and Sockets
Defect - Class 1,2,3 - Answer -- Tilt of the component exceeds maximum component
height limits
- Lead protrusion does not meet acceptance requirements due to tilt of component

Component Mounting - Radial Leads - Vertical

Información del documento

Subido en
6 de diciembre de 2025
Número de páginas
10
Escrito en
2025/2026
Tipo
Otro
Personaje
Desconocido
$14.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(367)
Vendido
2186
Seguidores
1449
Artículos
61484
Última venta
2 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes