The standard drainfield depth in East and Central Texas is limited to -
ANSWERS-18 inches minimum and 36 inches maximum


The minimum distance between standard drainfield excavations is -
ANSWERS-3 feet


Grease interceptors are needed - ANSWERS-on wastewater lines
from commercial kitchens


Which of the following is true if porous media in a standard
drainfield? - ANSWERS-It should be uniform in size, it should be
0.75 inch to 2 inches in size, it should be clean and resistant to
breakdown


A standard drainfield excavation should - ANSWERS-be level within
1 inch per 25 feet or a maximum of 3 inches whichever is less


A standard perforated drainline should be which of the following? -
ANSWERS-3 inches to 4 inches in diameter, a maximum length of
150 feet, laid parallel in multiple-line system

,The purpose of the geotextile fabric over gravel is to - ANSWERS-
prevent backfill from entering porous media


A pumped effluent drainfield - ANSWERS-is an alternative for well-
drained clay soils on nearly level sites, has a 2% or less slope for
single-family dwellings only


Which of the following must be known prior to actually laying out a
new OSSF? - ANSWERS-building location, size of the property, soil
conditions in the drainfield


In an unlined ET system, wastewater is disposed of by which of the
following? - ANSWERS-evaporation, transpiration, soil absorption


A gravelless pipe drainfield - ANSWERS-can be backfilled with Class
Ib, II, or III soil


A leaching chamber system - ANSWERS-requires 25% less
absorptive area than a standard system for new construction


Aerobic treatment units - ANSWERS-utilize aerobic bacteria and
oxygen to break down complex organics and produce carbon dioxide


To determine if a proprietary aerobic treatment unit is appropriate for
use with surface application disposal it must - ANSWERS-be on the
TCEQ's most recently approved list

, To determine the minimum size of aerobic treatment unit needed for a
particular home, one must know - ANSWERS-number of bedrooms
and square feet in the home and refer to TCEQ Table II


Which of the following is a likely cause of a "rotten egg" odor from
an aerobic treatment plant? - ANSWERS-Mechanical aerator failure,
hydraulic overload caused by leaking toilet


Which of the following is a way to evaluate an aerobic treatment plant
for excessive solids and need for wasting? - ANSWERS-30-minute
settling test


Which of the following is true of standard intermittent sand filter? -
ANSWERS-provides secondary wastewater treatment, has a
maximum surface loading rate of 1.2 gal/day/sqft, requires at least 24
inches of filter media which meets definite specifications (ASTM C-
33)


When would an intermittent sand filter with disinfection system be
selected over a properly designed and installed septic tank system? -
ANSWERS-For a standard drainfield in class Ia soil


Trickling filters and wetlands - ANSWERS-are secondary treatment
processes


Which of the following considerations should receive the greatest
emphasis in selecting a type of OSSF disposal option? - ANSWERS-
soil and site conditions

Información del documento

Subido en
5 de diciembre de 2025
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Teacher101
4.6
(279)
Vendido
544
Seguidores
74
Artículos
11865
Última venta
17 horas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes