ICC VAPOR RECOVERY-VT EXAM (ACTUAL 2025/2026) QUESTIONS WITH 100% VERIFIED CORRECT ANSWERS (GRADED A+ Diverts static electricity into earth. Eliminates static buildup. - ANSWER Grounding The Minimum level of Oxygen for a safe entry into a confined space shall be no less than what percentage? - ANSWER -19.5% The first physical signs of Oxygen depletion exposure are what? - ANSWER Respiration and heartbeat acceleration any space or enclosure that has limited opening for entry and exit and may have limited ventilation. - ANSWER -A Confined Space not considered confined space. - ANSWER -Sump bucket The most quickest route petroleum products may enter the body is: - ANSWER Inhalation Short term, high-level exposure, effects are usually immediate · - ANSWER Acute Exposure Long term, low level exposure, effects may take years to appear - ANSWER Chronic Exposure All of the following types of PPE are approved by OSHA, Except - ANSWER Safety Can Inverted coaxial hoses are used for what type of systems. - ANSWER -Vacuum Assist Stage 1 Vapor Recovery Systems are the transfer of Vapors from __________ to ___________. - ANSWER -From UST to fuel delivery truck Secondary containment testing must be completed by by ____ months after a new installation or upgrade. - ANSWER -6 Automatic line leak detectors shall be installed on underground pressurized piping and be capable to detect a 3-gallon per hour leak rate at 10 psi within 1 hour, with a probability of detection of at least ___? - ANSWER -95% Stage II Vapor Recovery Systems are the transfer of vapors from _________ to _________. - ANSWER -Vehicle Tank to UST Who is ultimately responsible at a (GDF) Gasoline Dispensing Facility? - ANSWER -Owner/ Operator You are conducting a maintenance repair and you have a gasoline spill, you shall take the following step as a safety precaution. - ANSWER -Call 911-barricade spill area-clean as much as you can and dispose of properly Pressure Decay Test is tested in the of the UST - ANSWER -Ullage The Phil-tite riser float shall have __of clearance when installed - ANSWER -13 inches Upgrade requirements for UST's, spill and overfill prevention and underground piping were required to be completed by what date? - ANSWER -December 22, 1998 A balanced system shall contain a nozzle equipped with a ______ - ANSWER Bellows On a Vacuum assist inverted coaxial hose, the vapors travel: - ANSWER -In the inside pathway of the hose The tank riser drop tube is typically installed: - ANSWER -Below the spill bucket A ball float prevention system is designed and installed to: - ANSWER -Alert the transfer operator when the tank is 90% full by restricting flow A UST will NOT require overfill prevention equipment if: - ANSWER -Transfers are less than 25 gallons at a time Suction piping operates at what pressure? - ANSWER -Less that atmospheric pressure close as practical to the suction pump, The maximum number of check valves allowed for a system that operates at less than atmospheric pressure shall be _ . - ANSWER -Below grade Spill containers shall be a minimum capacity of _____ - ANSWER -5 gallons Design & Construction requirements for New Underground Storage Tanks and all other components became effective. - ANSWER -January 1 1995 Tank Integrity Test means: test methods which are capable of detecting a leak of __ gallons per hour with a probability of detection of at least 95%. - ANSWER -0.1 Existing Underground Storage Tank means a UST installed prior to. - ANSWER January 1 1984 Where is a Vapor Shear valve located? - ANSWER -Under the dispenser Given that one valve shall remain open on a Healy Separator for normal operations, the valve that shall remain open is . - ANSWER -At the top The emergency shut-off valve is located. - ANSWER -Inside the kiosk

Vista previa del contenido

ICC VAPOR RECOVERY-VT EXAM (ACTUAL
2025/2026) QUESTIONS WITH 100% VERIFIED
CORRECT ANSWERS (GRADED A+

Diverts static electricity into earth. Eliminates static buildup. - ANSWER -
Grounding

The Minimum level of Oxygen for a safe entry into a confined space shall be no
less than what percentage? - ANSWER -19.5%

The first physical signs of Oxygen depletion exposure are what? - ANSWER -
Respiration and heartbeat acceleration

any space or enclosure that has limited opening for entry and exit and may have
limited ventilation. - ANSWER -A Confined Space

not considered confined space. - ANSWER -Sump bucket

The most quickest route petroleum products may enter the body is: - ANSWER -
Inhalation

Short term, high-level exposure, effects are usually immediate · - ANSWER -
Acute Exposure

Long term, low level exposure, effects may take years to appear - ANSWER -
Chronic Exposure

All of the following types of PPE are approved by OSHA, Except - ANSWER -
Safety Can

Inverted coaxial hoses are used for what type of systems. - ANSWER -Vacuum
Assist

, Stage 1 Vapor Recovery Systems are the transfer of Vapors from __________ to
___________. - ANSWER -From UST to fuel delivery truck

Secondary containment testing must be completed by by ____ months after a new
installation or upgrade. - ANSWER -6

Automatic line leak detectors shall be installed on underground pressurized piping
and be capable to detect a 3-gallon per hour leak rate at 10 psi within 1 hour, with a
probability of detection of at least ___? - ANSWER -95%

Stage II Vapor Recovery Systems are the transfer of vapors from _________ to
_________. - ANSWER -Vehicle Tank to UST

Who is ultimately responsible at a (GDF) Gasoline Dispensing Facility? -
ANSWER -Owner/ Operator

You are conducting a maintenance repair and you have a gasoline spill, you shall
take the following step as a safety precaution. - ANSWER -Call 911-barricade spill
area-clean as much as you can and dispose of properly

Pressure Decay Test is tested in the of the UST - ANSWER -Ullage

The Phil-tite riser float shall have __of clearance when installed - ANSWER -13
inches

Upgrade requirements for UST's, spill and overfill prevention and underground
piping were required to be completed by what date? - ANSWER -December 22,
1998

A balanced system shall contain a nozzle equipped with a ______ - ANSWER -
Bellows

On a Vacuum assist inverted coaxial hose, the vapors travel: - ANSWER -In the
inside pathway of the hose

Información del documento

Subido en
2 de diciembre de 2025
Número de páginas
11
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TopGradeGuru
1.5
(2)
Vendido
17
Seguidores
0
Artículos
2360
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes