P-99 / Low PSI Oil Burner Operator

A correctly adjusted oil burner flame could have an ____ coloured flame body with small ____,
barely cloudy recommendations. - ANS-Orange / Red

A risky situation occurs while oil pumped to the combustion chamber is not nicely ____. -
ANS-Atomized.

A faulty oil cut-off valve can lead to ____. - ANS-After-drip.

A purple, smoky flame is a sign of a ____. - ANS-Lack of air.

A faraway manage for oil burner is furnished to forestall what? - ANS-The flow of oil to any
burner.

A white, remarkable flame is an indication of ____. - ANS-Excess air.

Acceptance checks: Boilers shall no longer be placed in operation upon completion of
construction till they had been ____ and an equipment use allow has been issued through the
commissioner. - ANS-Inspected and examined.

After any gas burning system restore for which an authorized operator is required, such
operator shall additionally check the upkeep and be ____ whilst the device is began. -
ANS-Present.

After-drip can cause ____. - ANS-Carbon deposit build-up.

All heating, combustion, and cooking equipment will be furnished with insulation or the building
creation shall be hearth included, so that in operation the surface of combustible creation
substances will no longer be raised to a temperature higher than ____. - ANS-a hundred and
seventy ̊ F

An immoderate air deliver can also ____ the flame. - ANS-Blow out.

Assuming an outdoor place is impractical, in which can the far flung manage for oil burner be
located? - ANS-Immediately in the room in which the burner is placed.

At what RPM is oil atomized? - ANS-three,four hundred

Between what temperatures does the pre-heater convey the oil to? - ANS-one hundred sixty° -
180°F

, Between what temperatures must no. 6 gasoline-oil be maintained in the storage tank? - ANS-a
hundred ̊ - 130 ̊F

Blockage inside the chimney or flue passage will cause the boiler room to become ____. -
ANS-Filled with smoke.

Burner puff-again is most customarily due to a ____ in ignition. - ANS-Delay.

Dampers in flues will be constructed so that they can not completely ____ the passage of flue
gases at any time. - ANS-Cut off.

Dense, black smoke and soot is an indication of ____. - ANS-Insufficient air.

Each time one pound of carbon is burned, ____ BTU of heat are liberated. - ANS-14,544

Every oil burning set up that isn't always absolutely automated or calls for preheating shall be
operated by means of, or beneath, the direct supervision of a person holding a ____ issued by
using the hearth commissioner. - ANS-COF

For operated by hand burners using garage tanks with 60 gallons or much less ability, where
can the far flung manipulate for oil burner be installed? - ANS-In the supply strains between the
tank and burner.

For what motive is stress in a storage tank prohibited? - ANS-Discharging oil.

Heat within the combustion chamber that maintains the fireplace after the ignition is turned off is
known as ____. - ANS-Reflected heat.

Heavy oil together with no. 6 gas-oil is raised to approximately ____ before it enters the
combustion process. - ANS-one hundred eighty°F

How frequently must no. 6 gasoline-oil burner nozzles be wiped clean? - ANS-Daily.

If the fuel is not furnished with the proper amount of oxygen, carbon monoxide can be produced,
and only ____ BTU of heat are liberated. - ANS-4,480

If the oil spray combination contacts the ____ of the combustion chamber, it'll cause a smoky
fire. - ANS-Walls.

If ventilation for the cause of combustion is supplied robotically, the ventilating system shall be
____ interlocked with the burner. - ANS-Electrically.

In low stress oil burners, the oil and air combination is added to the nozzle at a strain between
____. - ANS-1 - 15 psi.

Información del documento

Subido en
24 de noviembre de 2025
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AllLegitExams
3.8
(43)
Vendido
125
Seguidores
8
Artículos
2331
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes