100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Puntuación
-
Vendido
-
Páginas
76
Grado
A+
Subido en
14-11-2025
Escrito en
2025/2026

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Institución
ARRT RADIOGRAPHY
Grado
ARRT RADIOGRAPHY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ARRT RADIOGRAPHY
Grado
ARRT RADIOGRAPHY

Información del documento

Subido en
14 de noviembre de 2025
Número de páginas
76
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

The target angle of the anode allows for a ________ actual focal spot, while producing a ________
effective focal spot. This effect is known as the ________. - CORRECT ANSWERS 1) Larger

2) Smaller

3) Line Focus Principle



The target angle may be ________ to ________ degrees, depending on the tube design. - CORRECT
ANSWERS 1) 7

2) 20



When electrons travel from the cathode to the anode, they travel at up to ________ the speed of
________. - CORRECT ANSWERS 1) Half

2) Light



When electrons strike the anode, the kinetic energy converts the electrons into ________ and
________. - CORRECT ANSWERS 1) Heat

2) X-Rays



When striking the anode, the electron conversion to heat is approximately ________%. - CORRECT
ANSWERS 99.8



When striking the anode, the electron conversion to x-rays is approximately ________%. - CORRECT
ANSWERS 0.2



________ are a calculation of the total heat produced during an x-ray exposure. - CORRECT
ANSWERS Heat Units



Heat units for single-phase full-wave rectified equipment is calculated via this formula: - CORRECT
ANSWERS kVp x mAs

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Heat units for three-phase, six-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.35



Heat units for three-phase, twelve-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.41



The x-ray tube for fluoroscopy is operated at ________ to ________ mA. - CORRECT ANSWERS
1) 3

2) 5



kVp and mAs are automatically adjusted during fluoroscopy by a process known as ________. -
CORRECT ANSWERS Automatic Brightness Control (ABC)



Automatic brightness control is also called ________ or ________. - CORRECT ANSWERS 1)
Automatic Brightness Stabilization

2) Automatic Gain Control



The ________ receives exit rays from the patient and converts then into visible light. - CORRECT
ANSWERS Input Phosphor



Visible light from the input phosphor strikes the ________, which is a thin layer next to the input
phosphor. - CORRECT ANSWERS Photocathode



The photocathode releases electrons in amounts ________ proportional to the visible light striking it. -
CORRECT ANSWERS Directly



Electrons from the photocathode are concentrated and directed toward the other end of the image-
intensifier tube by a series of ________ and by ________ kVp applied through the tube. - CORRECT
ANSWERS 1) Electrostatic Lenses (Focusing Lenses)

2) 25

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS


Once electrons are propelled across the tube from the photocathode, they strike the ________. -
CORRECT ANSWERS Output Phosphor



Once the energy of the electrons hits the output phosphor, it is converted by the phosphor to ________
in amounts ________ to ________ times greater than the photocathode. - CORRECT ANSWERS
1) Visible Light

2) 50

3) 75



The increase in brightness from the photocathode to the output phosphor is known as ________. -
CORRECT ANSWERS Flux Gain



The ________ phosphor is smaller than the ________ phosphor, resulting in an increase in brightness
known as ________. - CORRECT ANSWERS 1) Output

2) Input

3) Minification Gain



Total brightness gain is a product of ________ gain and ________ gain. - CORRECT ANSWERS 1)
Minification

2) Flux



Total brightness gain ranges from ________ to ________, and decreases as the tube ages. - CORRECT
ANSWERS 1) 5000

2) 20000



A complete program in a radiology department that addresses all aspects of quality, including customer
service, image interpretation, accuracy of diagnosis, and distribution of radiologists' reports is known as:
- CORRECT ANSWERS Quality Assurance

, ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

A program that specifically addresses the safe and reliable operation of equipment is known as: -
CORRECT ANSWERS Quality Control



A quality control program is required by ________. - CORRECT ANSWERS The Joint Commission



Collimation must be accurate to within ________% of the source-to-image receptor distance. -
CORRECT ANSWERS 2



The effective focal spot size should be within ________% of the size stated in the equipment
specifications. - CORRECT ANSWERS 50



kVp must be accurate to within ________% of the kVp indicated. - CORRECT ANSWERS 10



The exposure timer should be accurate to within ________% of the time chosen for exposures over 10
ms. - CORRECT ANSWERS 5



Adjacent mA stations should be accurate to within ________% of one another. This is known as
________. - CORRECT ANSWERS 1) 10

2) Exposure Linearity



Radiation intensity of sequential exposures should not vary more than ________%. This is known as
________. - CORRECT ANSWERS 1) 5

2) Exposure Reproduceability



The fluoroscopy exposure rate should be tested with a digital dosimeter, and should not be more
than________ per minute. - CORRECT ANSWERS 100 mGyᵃ



CR plates should be erased at least every ________. - CORRECT ANSWERS 48 Hours
$28.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
bestScience Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
74
Miembro desde
3 año
Número de seguidores
61
Documentos
3657
Última venta
1 mes hace

3.2

9 reseñas

5
3
4
2
3
0
2
2
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes