LMRT Exam
with Q & A
bundle
Radial artery - Most common site for palpitation of a patient's pulse.



Respiration - Vital sign that can be assessed without touching the patient.



AED - Device used to return the heart to a normal rhythm when a patient in cardiac
arrest presents with a rapid, weak, and ineffective heartbeat.



CPR - Basic life support system used to ventilate the lungs and circulate the blood in the
event of cardiac arrest.



Anaphylaxis - Severe allergic reaction.



Fomite transmission - Opportunity for disease transmission when linens are not changed
between patients.

,Frequent handwashing - Single best protection against disease for healthcare workers.



Asepsis - Process of reducing the probability that infectious organisms will be transmitted
to a susceptible individual.



Standard precautions - Involve the use of barriers whenever contact is anticipated with
blood, body fluids, or mucus membranes.



Indirect contact or fomite transmission - Type of disease transmission possible when the
limited operator does not clean the Bucky device after performing an examination on a patient
with influenza.



Proper body mechanics - Correct statements include: 1. Use of a broad stance, 2. Turn
and lift using your back muscles, 3. Carry heavy objects close to your body (1,3 only).



Mrs. Dunbar - Most likely to respond appropriately if addressed as such.



Radiation dose and genetic effects - The link has been demonstrated in animal studies;
increased risk to humans cannot be predicted with respect to an individual.



Increase kVp by 15% - Change in kilo voltage that results in the greatest reduction of
patient dose when milliampere-seconds is adjusted to compensate.



Gonad shields - Primary purpose is to reduce the likelihood of genetic effects.



Types of gonad shields - Contact and Shadow.

,Gonad shielding - Should be used when the gonads are within 5 cm of the radiation field.



Repeated exposures - Greatest cause of unnecessary radiation to patients that can be
controlled by the limited operator.



Clearly instructing patients - Method to reduce repeat exposures.



X-ray beam restriction - Minimizes patient exposure by limiting the radiation field to the
area of interest.



Collimator - Device that allows the limited operator to vary the size of the radiation field.



Filtration - Reduces patient exposure by removing longer-wavelength photons.



NCRP recommendation for total filtration - 2.5 mm Al equiv.



Methods to protect limited operators - Three principle methods are Time, distance,
shielding.



Personnel radiation shielding - Shadow is not a type.



Greatest radiation hazard - Scattered radiation from the patient when personnel shielding
is worn during exposure.



Leakage radiation - Term for radiation that escapes from the x-ray tube.

, Occupationally exposed individuals - Limited operators are prohibited from activities that
result in direct exposure to the primary x-ray beam.



Distance - Means that the operator should maximize the distance from the source during
an exposure.



Scatter radiation - Source of exposure that personnel shielding is designed to attenuate.



TLD - Acronym for a common type of personnel dosimeter.



Placement for personnel dosimeter - The badge should be worn in the region of the
collar on the anterior surface of the body and outside the lead apron, if worn.



NCRP recommended annual effective dose limit - 50 mSv (0.05 Sv).



NCRP recommended monthly effective dose limit to the fetus - 0.5 mSv (0.0005 Sv).



Radiation monitoring requirement - Required when 10% of the annual occupational
effective dose limit is likely to be received.



Conventional radiation unit for intensity - Roentgen.



Conventional unit for occupational dose - REM.



Conventional radiation unit for absorbed dose - Rad.

Información del documento

Subido en
4 de noviembre de 2025
Número de páginas
50
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Cleverman
5.0
(1)
Vendido
9
Seguidores
1
Artículos
2042
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes