LINEMAN APPRENTICE EXAMS SCRIPT QUESTIONS AND
SOLUTIONS GRADED A+
✔✔What device changes AC to DC? - ✔✔Commutator (the process is called
commutation)

✔✔The Maximum use voltage for class 3 gloves is _______ volts - ✔✔26,500 volts

✔✔The size of a crew needed to pike a 30 ft pole is _______, 35 ft _______, 40 ft
_______, 45 and 50 ft _______ - ✔✔6 (30 ft), 7 (35 ft), 8 (40 ft), 10 (45 &50 ft)

✔✔True or False- When applying a splice on wire, the wire should be straight for a
distance of 10' - ✔✔True

✔✔Which 2 voltage types on Transmission lines require a corona shield? - ✔✔Extra
and Ultra High Voltage (shields are at each point of conductor support)

✔✔A ground rod that penetrates perpetually moist earth will have a fairly ________
resistance. - ✔✔Low

✔✔XLPE=______ - ✔✔Cross linked polyethylene

✔✔EPR=_________ - ✔✔Ethylene, Propylene, Rubber

✔✔Current lags voltage in ______ devices, current leads voltage in ________ devices.
- ✔✔Inductive, capacitive

✔✔True or False-Distribution transformers should be installed as close as possible to
the center of the load that it's feeding. - ✔✔True

✔✔A swiss engineer named _____________ developed a high voltage DC
transmission system in _____________. - ✔✔Thury, 1899

✔✔True or False- The top of your climbers should be approximately 4 in below the
inside prominence of the knee joint. - ✔✔False (hooks are adjustable in 1/2 in
increments 14-20 inches)

✔✔____________ designed and buried a transmission system using copper rods
insulated with jute. - ✔✔Thomas Edison

✔✔Before lowering a victim to the ground, 2 rescue breathes should be given so that
the throat tissue has less of a chance of swelling shut and the heart will be more likely
to keep beating. - ✔✔Yeah do that.

, ✔✔An ___________ ______________ when used for service entrance protection and
coordination, the electric fuses provide a buffer to prevent in-plant problems on the
customer system from affecting service on the utility company system. - ✔✔electronic
fuse

✔✔The location of protective devices such as PMR, are known as ______________. -
✔✔Coordination points (these devices protect from over current)

✔✔Before installing grounds on a conductor, it should first be __________. - ✔✔Tested
for voltage

✔✔Hot line tools are factory tested at ___________ volts per foot - ✔✔100,000

✔✔The first electric lights were called electric arc lamps and the first place they were
installed was ____________. - ✔✔Paris, France

✔✔The air we breathe has ______% oxygen. We use _____% and exhale _____%. -
✔✔21% initially, 5% used, 16% exhaled

✔✔Transmission and Distribution line conductors must be joined with full tension
splices if the conductors are under tension.

Bolted or squeeze-on connections may be used where the line is slack. - ✔✔True

✔✔In transmission, it is sometimes necessary to first splice steel core, then splice the
outer alum wires. When finished, the outer splice is filled with _______ _________ to
prevent oxidation of the splice. - ✔✔Zinc Chromate

✔✔Automatic splice is used where one expects to have 15% of the rated breaking
strength of the conductor.

Tension should be applied at all times or else the jaws may release and allow the
conductor to drop out. - ✔✔

✔✔By using a popsicle, what problem is eliminated? - ✔✔Cold flow problems of a
stranded alum conductor in a copper clamp (such as a tank ground or hot line clamp)

✔✔When choosing the order of conductors when making connections, in which order
should copper and alum be placed? - ✔✔Aluminum over copper

✔✔When using armor rods, the attachment of the conductor to the insulator should be
in the middle of the armor rod. - ✔✔

Información del documento

Subido en
24 de octubre de 2025
Número de páginas
13
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TIPSTAR
3.4
(20)
Vendido
165
Seguidores
6
Artículos
27156
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes