1. In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as close to the end
of the coil as possible in order to:

A. Operate at high-efficiency

B. Ensure that Frost is not accumulate

C. Subcool the compressor

D. Ensure proper oil return Ans: ✓ ✓ ✓ A. Operate at high-efficiency

2. The difference between the temperature of the refrigerant boiling in the evaporator and the
temperature at the evaporator outlet is known as

A. Evaporator superheat

B. Latent heat

C. Evaporator sub-cooling

D. Sublimation Ans: ✓ ✓ ✓ A. Evaporator superheat

3. An expansion device that is stuck open will cause

A. Low suction pressure

B. A starved evaporator

C. Excessive superheat

D. A flooded evaporator Ans: ✓ ✓ ✓ D. A flooded evaporator

4. When measuring evaporator superheat on a commercial system that has a long suction line, the
pressure reading should be taken at the
© Get it right 2025 Getaway - Stuvia US All rights reserved

,Click here for more: Scholars nexus
A. Compressor inlet

B. Evaporator outlet

C. Condenser outlet

D. Receiver Inlet Ans: ✓ ✓ ✓ A. Compressor inlet

5. Superheat measurements are best taken

A. During a hot pulldown

B. At 8°F two 12°F

C. During defrost

D. With the system operating at design conditions Ans: ✓ ✓ ✓ D. With the system operating at
design conditions

6. A technician is checking the superheat on a multi circuit evaporator and finds one of the circuits
has a superheat that is higher than the others. This could be caused by

A. A dirty coil

B. A refrigerant overcharge

C. Uneven air distribution

D. A blocked distributor Ans: ✓ ✓ ✓ D. A blocked distributor

7. A TXV with an external equalizer is used on

A. Evaporators with a high pressure drop

B. Evaporators with a low pressure drop

C. High temperature application is only

D. All evaporators Ans: ✓ ✓ ✓ A. Evaporators with a high pressure drop

8. Dry type evaporators operate most efficiently with the superheat setting of approximately

A. 8°F to 12°F

© Get it right 2025 Getaway - Stuvia US All rights reserved

, Click here for more: Scholars nexus
B. 13°F to 19°F

C. 20°F to 30°F

D. 31°F to 40°F Ans: ✓ ✓ ✓ A. 8°F to 12°F

9. An evaporator used to chill liquids is operating within normal superheat setting. But the system is
not cooling the product properly. Which of the following is most likely the cause?

A. Overcharge of refrigerant

B. Undercharge of refrigerant

C. The circulator

D. The TXV Ans: ✓ ✓ ✓ A. Overcharge of refrigerant

10. What time interval is required between each superheat adjustment?

A. Not less than one hour

B. About 10 to 15 minutes

C. At least a half hour

D. No time delay Ans: ✓ ✓ ✓ B. About 10 to 15 minutes

11. A low temperature evaporator used for cooling space or product refrigeration

A. Is the same as one used for medium or high temperatures

B. Must have fins space closer together

C. Must be frosted periodically

D. Must be defrosted periodically Ans: ✓ ✓ ✓ D. Must be defrosted periodically

12. Some special applications use a flooded evaporator (operated full of refrigerant) in order to
maintain the proper level of liquid refrigerant, a ______ type devices used.

A. High side float

B. Capillary tube

© Get it right 2025 Getaway - Stuvia US All rights reserved

Información del documento

Subido en
10 de octubre de 2025
Número de páginas
25
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Novalearn
3.6
(7)
Vendido
27
Seguidores
0
Artículos
5220
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes