• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 182 páginas
Examen

Cht Exam Complete Study Guidecomplete Study Guide Questions With 100%Verified Answers

Document preview thumbnail
Vista previa 4 fuera de 182 páginas

CHT EXAM COMPLETE STUDY GUIDE QUESTIONS WITH 100%VERIFIED ANSWERS .____ a EDTA is preferred over ACD as an additive for molecular testing - Answer-True .____ b- EDTA chelates calcium and is acceptable for CDC assays - Answer-False .____ c- EDTA is acceptable for flow cytometry assays - Answer-True .____ d- Moderate hemolysis of serum should not interfere with PRA testing - Answer-True .____ e- Plasma is unacceptable for CDC PRA testing - Answer-True .____ f- Heparinized blood is acceptable for molecular testing - Answer-True, MOSTLY .____ g- Heparin does not interfere with Taq polymerase - Answer-False .____ h- Lithium heparin is an acceptable substitute for sodium heparin - Answer-False .____ i- It is acceptable for a red top to be collected from a patient who is at that moment receiving a dialysis treatment - Answer-False .____ j- Blood shipped to the lab for serology testing should be kept at 4 degrees - Answer-False .____ k- Patients receiving long-term steroid treatment may have insufficient lymphocytes for HLA testing - Answer-True .____ l- Patients receiving blood products should have their blood collected for HLA typing immediately following the transfusions to ensure adequate cell numbers - Answer-False .____ m- You should ask for the WBC and differential on leukopenic and pediatric patients to determine how much blood should be collected for HLA typing - Answer-True .____ n- Requisition forms must include name of an authorized requester - Answer-True .____ o- Plain red top, EDTA and ACD are all acceptable samples for ABO blood grouping - Answer-True .____ p- Lymphocytes from EBV transformed cell lines react the same as PBLs in CDC assays - Answer-False .____ q- The color of the stopper is a universal code for a vacutainer's contents - Answer-False .____ r- EDTA blood stored for 1 year at RT is an acceptable sample - Answer-False .____ s- Blood spotted on SS 903 cards and stored for 1 year at RT is an acceptable sample - Answer-True .____ t- ACD tubes maintain cell viability are better than heparin during long transit times - Answer-True ._____ also inspect laboratories, and because of its deemed status with other regulatory agencies (OSHA, HCFA, UNOS, JCAHO), It is compelled to notify those agencies when an incidence occur. - Answer-ASHI .______ has the mandate to control pollution of environment - Answer-EPA ._______ are the major receptor cluster expressed on human NK cells and subset of T cells. - Answer-KIRs .________ is an ultra-sensitive fluorescent dye that undergoes a dramatic fluorescence enhancement upon binding to dsDNA that can be measured using a microplate fluorometer. Simpler and more sensitive (ability to detect 1ng/mL of dsDNA) compared to Hoechst 33258 Dye. - Answer-PicoGreen ._________ are typically cold reacting (4oC) and________are typically warm reacting (22-37oC). - Answer-Autoantibodies B cell antibodies ._________ would be helpful in determining the volume of blood needed for testing. - Answer-WBC count .__________ are increasingly recognized as an important immune component involved in immune surveillance, anti-infection, as well as alloimmune response. - Answer-Natural killer (NK) cells .___________ must be chosen so that the markers are flanking on each side the expected DNA migration. They are used to determine migration outcome by comparing the patient specimen migration with the known marker migration. - Answer-The DNA ladder ._______________ is a fluorescent dye that intercalates between the bases of DNA and RNA. - Answer-Ethidium bromide ."MISSING SELF" ON A CANCEROUS OR INFECTED CELL PERMITS ______ ACTIVATION - Answer-NK .(ASHI) - Answer-American Society of Histocompatibility and Immunogenetics .(FBS) - Answer-Fetal Bovine Serum can be a suitable substitute for PHS. However, FBS may be cytotoxic to human cells and, therefore, must be tested in CDC assays prior to use in typing trays. .(IHWG) - Answer-With International Histocompatibility Workshop Group .(PHS) - Answer-Pooled human sera from non-immunized, blood group AB male donors. PHS provides an additional protein source that is essential in maintaining the integrity of cell membranes during cell growth, storage or any subsequent testing. .(SEOPF) - Answer-Southeastern Organ Procurement Foundation .(WHO) - Answer-World Health Organization .• All immunogens are antigens but... - Answer-• All antigens are not immunogens .3% granulocyte contamination - Answer-Density of granulocytes altered due to disease state or abnormal blood sample Specific gravity of FH is too High. Must be 1.077. Use thrombin, ncarbonyl iron, and Lympho-Kwik™ Reagent. .10C - Answer-A25, A26, A32, A33, A34, A43, A66, A74 .12C - Answer-B13, B37, B41, B44, B45, B47, B49, B50, B60, B61 .192. Thrombin or CaCl2 are typically used for... a. Clotting anti-coagulated plasma b. Selectively removing macrophages c. Isolating DNA d. "Reviving" dead donor cells for an AHG crossmatch - Answer-a. Clotting anti-coagulated plasma .1C - Answer-A1, A3, A11, A29, A30, A31, A36, A80

Vista previa del contenido

CHT EXAM COMPLETE STUDY GUIDE
QUESTIONS WITH 100%VERIFIED
ANSWERS



\.____ a EDTA is preferred over ACD as an additive for molecular testing - Answer- True



\.____ b- EDTA chelates calcium and is acceptable for CDC assays - Answer- False



\.____ c- EDTA is acceptable for flow cytometry assays - Answer- True



\.____ d- Moderate hemolysis of serum should not interfere with PRA testing - Answer- True



\.____ e- Plasma is unacceptable for CDC PRA testing - Answer- True



\.____ f- Heparinized blood is acceptable for molecular testing - Answer- True, MOSTLY



\.____ g- Heparin does not interfere with Taq polymerase - Answer- False



\.____ h- Lithium heparin is an acceptable substitute for sodium heparin - Answer- False



\.____ i- It is acceptable for a red top to be collected from a patient who is at that moment
receiving a dialysis treatment - Answer- False

,\.____ j- Blood shipped to the lab for serology testing should be kept at 4 degrees - Answer-
False



\.____ k- Patients receiving long-term steroid treatment may have insufficient lymphocytes for
HLA testing - Answer- True



\.____ l- Patients receiving blood products should have their blood collected for HLA typing
immediately following the transfusions to ensure adequate cell numbers - Answer- False



\.____ m- You should ask for the WBC and differential on leukopenic and pediatric patients to
determine how much blood should be collected for HLA typing - Answer- True



\.____ n- Requisition forms must include name of an authorized requester - Answer- True



\.____ o- Plain red top, EDTA and ACD are all acceptable samples for ABO blood grouping -
Answer- True



\.____ p- Lymphocytes from EBV transformed cell lines react the same as PBLs in CDC assays -
Answer- False



\.____ q- The color of the stopper is a universal code for a vacutainer's contents - Answer-
False



\.____ r- EDTA blood stored for 1 year at RT is an acceptable sample - Answer- False



\.____ s- Blood spotted on SS 903 cards and stored for 1 year at RT is an acceptable sample -
Answer- True

,\.____ t- ACD tubes maintain cell viability are better than heparin during long transit times -
Answer- True



\._____ also inspect laboratories, and because of its deemed status with other regulatory
agencies (OSHA, HCFA, UNOS, JCAHO), It is compelled to notify those agencies when an
incidence occur. - Answer- ASHI



\.______ has the mandate to control pollution of environment - Answer- EPA



\._______ are the major receptor cluster expressed on human NK cells and subset

of T cells. - Answer- KIRs



\.________ is an ultra-sensitive fluorescent dye that undergoes a dramatic fluorescence

enhancement upon binding to dsDNA that can be measured using a microplate fluorometer.

Simpler and more sensitive (ability to detect 1ng/mL of dsDNA) compared to Hoechst 33258

Dye. - Answer- PicoGreen



\._________ are typically

cold reacting (4oC) and________are typically warm reacting (22-37oC). - Answer-
Autoantibodies

B cell antibodies



\._________ would be helpful in determining the volume of blood needed for testing. - Answer-
WBC count



\.__________ are increasingly recognized as an important immune

component involved in immune surveillance, anti-infection, as well as alloimmune

, response. - Answer- Natural killer (NK) cells



\.___________ must be chosen so that the markers are flanking

on each side the expected DNA migration. They are used to determine migration outcome by

comparing the patient specimen migration with the known marker migration. - Answer- The
DNA ladder



\._______________ is a fluorescent dye that intercalates between the

bases of DNA and RNA. - Answer- Ethidium bromide



\."MISSING SELF" ON A CANCEROUS OR INFECTED CELL PERMITS ______ ACTIVATION - Answer-
NK



\.(ASHI) - Answer- American Society of Histocompatibility and Immunogenetics



\.(FBS) - Answer- Fetal Bovine Serum can be a suitable substitute for PHS. However, FBS may
be cytotoxic to human cells and, therefore, must be tested in CDC assays prior to use in typing
trays.



\.(IHWG) - Answer- With International Histocompatibility Workshop Group



\.(PHS) - Answer- Pooled human sera from non-immunized, blood group

AB male donors. PHS provides an additional protein source that is essential in maintaining the
integrity of cell

membranes during cell growth, storage or any subsequent testing.



\.(SEOPF) - Answer- Southeastern Organ Procurement Foundation

Información del documento

Subido en
29 de septiembre de 2025
Número de páginas
182
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
IszackBd
5.0
(3)
Vendido
67
Seguidores
4
Artículos
6603
Última venta
3 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes