Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 402 páginas
Examen

Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma, Thomas Overbye, Adam Birchfield

Document preview thumbnail
Vista previa 4 fuera de 402 páginas

Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma, Thomas Overbye, Adam Birchfield

Vista previa del contenido

Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield




Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield

,Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield


Contents

Chapter 2............................................................................................................................ 1

Chapter 3.......................................................................................................................... 24

Chapter 4.......................................................................................................................... 63

Chapter 5.......................................................................................................................... 85

Chapter 6........................................................................................................................ 125

Chapter 7........................................................................................................................ 160

Chapter 8........................................................................................................................ 166

Chapter 9 ...................................................................................................................... 185

Chapter 10...................................................................................................................... 219

Chapter 11...................................................................................................................... 293

Chapter 12...................................................................................................................... 314

Chapter 13...................................................................................................................... 333

Chapter 14...................................................................................................................... 346

Chapter 15...................................................................................................................... 369




Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield

,Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield




Chapter 2
Fundamentals



2.1 (a) 𝐴̅1 = 9∠30° = 9[𝑐𝑜𝑠 30° + 𝑗 𝑠𝑖𝑛 30°] = 7.8 + 𝑗4.5
5
(b) 𝐴̅2 = 4 + 𝑗5 = √16 + 25 ∠ 𝑡𝑎𝑛−1 4 = 6.40∠128.66° = 6.40𝑒𝑗128.66°

(c) 𝐴̅3 = (7.8 + 𝑗4.5) + (−4 + 𝑗5) = (11.8 + 𝑗9.5) = 15.15∠38.8°


(d) 𝐴̅4 = (9∠30°)(6.4∠51.34°) = 57.6∠81.34° = 8.673 + 𝑗56.9
(e) 𝐴̅5=
9∠30° = 1.41∠81.34° = 1.41𝑒𝑗81.34°
6.4∠−52.34°

2.2 (a) 𝐼̄ = 500∠ − 30° = 433.01 − 𝑗250
(b) 𝑖(𝑡) = 4𝑠𝑖𝑛(𝜔𝑡 + 15°) = 4𝑐𝑜𝑠(𝜔𝑡 + 15° − 90°) = 4co s(𝜔𝑡 − 75°)
4
𝐼̄ = ∠ − 75° = 2.83∠ − 75° = 0.73 − 𝑗2.73
√2

(c) 𝐼̄ = (5/√2)∠ − 15° + 4∠ − 60° = (3.42 − 𝑗0.92) + (2 − 𝑗3.46)
= 5.42 − 𝑗4.38 = 6.964∠ − 38.94°
13
2.3 𝑉̅2 = ∠(−(125 × 10−6)(2𝜋60)) kV = 9.19∠ − 2.7° kV
√2
− j6 6 − 90
2.4 (a) I = 100 = 10 = 7.5 − 90 A
1
8 + j6 − j6 8
I2 = I − I1 = 100 − 7.3 − 90 = 10 + j7.5 = 12.536.87 A
V = I2 (− j6) = (12.536.87) (6 − 90) = 75 − 53.13 V

(b)




1
© 2023 Cengage Learning®. May not be scanned, copied, or duplicated, or posted to a publicly accessible website, in whole or in part.

, Solution Manual For Power System Analysis and Design 7th Edition by J. Duncan Glover, Mulukutla S. Sarma,
Thomas Overbye, Adam Birchfield




2.5 (a) (t) = 277 2 cos(t + 30) = 391.7cos(t + 30)V
𝑉̅
(b) 𝐼̄ = = 6.155∠30° A
45

𝑖(𝑡) = 8.7 cos (𝜔𝑡 + 30°) A


(c) Z = jL = j (2 60)(10 10−3 ) = 3.77190 
I = V Z = (27730) (3.77190) = 73.46  − 60A
i(t) = 73.46 2 cos(t −60)=103.9cos(t −60)A

(d) Z = − j 25 
I =V Z = (27730) (25 − 90) = 11.08120 A
i(t) = 11.08 2 cos(t + 120) = 15.67cos(t + 120)A
75
2.6 (a) 𝑉̅ = ( ) ∠ − 15° = 53.03∠ − 15°;  does not appear in the answer.
√2

(b) 𝜐(𝑡) = 50√2 𝑐𝑜𝑠(𝜔𝑡 + 10°); with  = 377,
𝜐(𝑡) = 70.71 𝑐𝑜𝑠(377𝑡 + 10°)
(c) 𝐴̅ = 𝐴̅∠𝛼; 𝐵̄ = 𝐵̄∠𝛽; 𝐶̄ = 𝐴̅ + 𝐵̄
c(t) = a(t) + b(t) = 2 Re Ce jt 
The resultant has the same frequency .
2.7 (a) The circuit diagram is shown below:




(b) 𝑍̶̄ = 3 + 𝑗8 − 𝑗4 = 3 + 𝑗4 = 5∠53.1° 𝛺
(c) I = (1000) (553.1) = 20 − 53.1 A

The current lags the source voltage by 53.1
Power Factor = cos53.1 = 0.6 Lagging




2
© 2023 Cengage Learning®. May not be scanned, copied, or duplicated, or posted to a publicly accessible website, in whole or in part.

Libro relacionado
 image
J. Duncan Glover, Mulukutla S. Sarma, Thomas Overbye, Adam Birchfield Power System Analysis and Design
Editorial: 2022 ISBN: 9780357676189 Edición: Desconocido

Información del documento

Subido en
29 de septiembre de 2025
Número de páginas
402
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$25.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
StudyAtlas
3.8
(436)
Vendido
1860
Seguidores
1470
Artículos
7255
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes