• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 9 páginas
Examen

Physical Security (Test)/PCS Test guide with complete solution latest update

Document preview thumbnail
Vista previa 2 fuera de 9 páginas

Physical Security (Test)/PCS Test guide with complete solution latest update

Vista previa del contenido

Physical Security (Test)/PCS Test guide
with complete solution latest update

D-Ring - ANS What is required on an OSHA approved harness for fall protection

6" or greater - ANS Openings _______ or greater at stairways, walkways, and open decks
must be guarded/covered

6' or above - ANS All window, door, and access openings _____ or above grade must be
guarded

2x4 or better - ANS Window and door guards must be ______

19.2" OC with 18" opening OR 24" OC with 2 rows of blocking & 3-1/2" toe kick - ANS For
clear story framing, stud bay spacing is not to exceed _______ OC with _____ opening OR
_______ OC with ____ rows of blocking and _____ toe kick

10ft or higher - ANS Working platforms have guardrails when _______ or higher

Planked - ANS Working platforms on scaffolds and decks are fully ______

At least 6", not more than 12" - ANS Scaffold planks are to be overlapped at least ___ but not
more than ___

Curb to curb - ANS ____ to ____ hard hat policy on all active construction sites

Eye protection - ANS ____________ must be worn when cutting, sawing, using nail guns,
mixing stucco or mortar, etc

N95 mask/respirator - ANS To be worn while cutting/ripping cement type siding, mixing stucco
or gypsum mortar or when working with any products that contains silica or other harmful
particles

3ft above roofline, 10ft tied off - ANS Ladders must extend ____ft above roof line and ladders
above ____ft must be tied off

Storm Water Pollution Prevention Plan - ANS What does SWPPP stand for?

True - ANS Containment is required under gasoline powered equipment

3000 PSI - ANS Minimum concrete PSI needed is...

, Concrete is placed in a continuous pour for monolithic slabs and walls - ANS True

1 gallon per cubic yard - ANS Water added on site is no more than ___ gallon(s) per cubic yard

90 minutes - ANS Concrete is discharged within ____ minutes after introduction of water to
cement

12 inches - ANS All exterior footings shall be placed at least ____ inches below the
undisturbed soil unless otherwise specified by EOR

1/4 thickness, 10ft intervals, 24 hours - ANS All non-post tensioned slabs have control joints
cut or tooled _____ thickness of the slab at _____ intervals within _____ hours of placement

2 or more - ANS Expansion joint in flatworm when the concrete slab is confined on ____ or
more sides

False - ANS Vegetative growth is allowed on pad area where concrete is poured

Sheathing or Wrapping - ANS Pipes passing through concrete are protected with _____ or
_____ that allows for movement including expansion and contraction of piping. Wall thickness
not less than 0.025 inch

Pipe Sleeve, 2 pipe sizes - ANS Pipes passing through a foundation wall shall be provided with
a _____ ______ that shall be built into the foundation wall. It shall be ____ pipe sizes greater
than the pipe passing through the wall

Backfilled & compacted - ANS All plumbing, electrical, and chases have been ______ and
_____ in accordance with soils report

Below the slab - ANS All conduits should be placed _____ the ______ as to not impact the
thickness of the slab

4" - ANS The slab depth is

2 rebar 24" OC - ANS What is placed diagonally over re-entrant corners

8" - ANS Overlap of wire mesh is 2 squares which is measured as ...

1/8" - ANS What is the gap size between all OSB sheathing?

16" OC - ANS Furring strip spacing at all tub and shower walls is...

Información del documento

Subido en
25 de septiembre de 2025
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CUTENURSE1
4.7
(20)
Vendido
124
Seguidores
30
Artículos
2390
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes