Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 4 fuera de 34 páginas
Examen

EDELMAN SPI EXAM WITH QUESTIONS AND WELL VERIFIED ANSWERS|| GUARANTEED PASS || ALREADY GRADED A+ || LATEST UPDATE 2025

Document preview thumbnail
Vista previa 4 fuera de 34 páginas

EDELMAN SPI EXAM WITH QUESTIONS AND WELL VERIFIED ANSWERS|| GUARANTEED PASS || ALREADY GRADED A+ || LATEST UPDATE 2025 What is the "talking" portion of pulsed sound? - ANSWER-the transmit of the pulse What is the "listening" portion of pulsed sound? - ANSWER-the receiving portion of the pulse What is pulse duration? - ANSWER-the actual time from the start of a pulse to the end of that pulse What is the unit for pulse duration? - ANSWER-microseconds What is pulsed duration determined by? - ANSWER-sound source Is pulse duration adjustable by the sonographer? - ANSWER-No What is the relationship between frequency and pulse duration? - ANSWER inversely related How can you calculate the pulse duration? - ANSWER-# of cycles x period so how many cycles multiplied by how fast it takes for each cycle to complete Pulse duration is ____________ related to the number of cycles in the pulse. - ANSWER-directly Pulse duration is __________ related to period. - ANSWER-directly In clinical imaging, how many cycles are typically in one pulse? - ANSWER-2 4 Under which circumstance is cavitation most likely to occur? - ANSWER-Low frequency and high signal amplitude Where does coded excitation originate? - ANSWER-In the pulser What are typical clinical doppler frequencies? - ANSWER-1-10,000Hz What doppler angle is most inaccurate? 3 - ANSWER-60-75 degrees What can be changed that would not cause any change in a hard copy image output? - ANSWER-Display brightness and contrast A quality assurance program: - ANSWER-Is needed by all labs What is the actual time that an US machine is creating a pulse? - ANSWER Pulse duration The angle of incidence of an US beam is perpendicular to an interface. The two media have the same propagation speeds. What process cannot occur? - ANSWER-Refraction What component of the US unit contains the memory bank? - ANSWER-Scan converter An US wave travels through two media and has attenuation of 3dB in the first and 5dB in the second. What is the total attenuation? - ANSWER-8dB According to the AIUM statement on bioeffects, there have een no confirmed bioeffects below the intensities of __________ watts per square centimeter SPTA. - ANSWER-0.1 Fill-in of an anechoic structure such as a cyst is known as? - ANSWER-Partial volume artifact, slice thickness artifact, section thickness artifact What is the range of frequencies created by medical diagnostic doppler transducers? - ANSWER-2-10MHz Doppler shifts are always created when the source and receiver are in motion relative to each other (TRUE OR FALSE) - ANSWER-False What is the significance of gray scale variation in the spectrum of a pulsed wave doppler display? - ANSWER-It represents the number of red blood cells creating the reflection

Vista previa del contenido

EDELMAN SPI EXAM WITH QUESTIONS AND
WELL VERIFIED ANSWERS|| GUARANTEED
PASS || ALREADY GRADED A+ || LATEST
UPDATE 2025




What is the "talking" portion of pulsed sound? - ANSWER-the transmit of the
pulse


What is the "listening" portion of pulsed sound? - ANSWER-the receiving
portion of the pulse


What is pulse duration? - ANSWER-the actual time from the start of a pulse to
the end of that pulse


What is the unit for pulse duration? - ANSWER-microseconds


What is pulsed duration determined by? - ANSWER-sound source


Is pulse duration adjustable by the sonographer? - ANSWER-No


What is the relationship between frequency and pulse duration? - ANSWER-
inversely related


How can you calculate the pulse duration? - ANSWER-# of cycles x period

,so how many cycles multiplied by how fast it takes for each cycle to complete


Pulse duration is ____________ related to the number of cycles in the pulse. -
ANSWER-directly


Pulse duration is __________ related to period. - ANSWER-directly


In clinical imaging, how many cycles are typically in one pulse? - ANSWER-2-
4
Under which circumstance is cavitation most likely to occur? - ANSWER-Low
frequency and high signal amplitude


Where does coded excitation originate? - ANSWER-In the pulser


What are typical clinical doppler frequencies? - ANSWER-1-10,000Hz


What doppler angle is most inaccurate? <3 - ANSWER-60-75 degrees


What can be changed that would not cause any change in a hard copy image
output? - ANSWER-Display brightness and contrast


A quality assurance program: - ANSWER-Is needed by all labs


What is the actual time that an US machine is creating a pulse? - ANSWER-
Pulse duration


The angle of incidence of an US beam is perpendicular to an interface. The two
media have the same propagation speeds. What process cannot occur? -
ANSWER-Refraction

,What component of the US unit contains the memory bank? - ANSWER-Scan
converter


An US wave travels through two media and has attenuation of 3dB in the first
and 5dB in the second. What is the total attenuation? - ANSWER-8dB


According to the AIUM statement on bioeffects, there have een no confirmed
bioeffects below the intensities of __________ watts per square centimeter
SPTA. - ANSWER-0.1


Fill-in of an anechoic structure such as a cyst is known as? - ANSWER-Partial
volume artifact, slice thickness artifact, section thickness artifact


What is the range of frequencies created by medical diagnostic doppler
transducers? - ANSWER-2-10MHz


Doppler shifts are always created when the source and receiver are in motion
relative to each other (TRUE OR FALSE) - ANSWER-False


What is the significance of gray scale variation in the spectrum of a pulsed wave
doppler display? - ANSWER-It represents the number of red blood cells
creating the reflection


Which set of property of a test phantom is most relevant when assessing depth
calibration accuracy? - ANSWER-Reflector spacing and propagation speed


The relative output of an US instrument is calibrated in dB and the operator by
60 dB. The beam intensity is increased by? - ANSWER-One million times


What is the most typical doppler shift measured clinically? - ANSWER-2kHz

, Doppler shifts always occur if the source and receiver are in motion relative to
each other (TRUE OR FALSE) - ANSWER-False


Doppler shifts always occur if the source and observer are in motion relative to
each other and the angle between the motion and the sound beam is 90degrees
(TRUE OR FALSE) - ANSWER-False


Doppler shifts always occur if the source and observer are in motion relative to
each other and the angle between the motion and the sound beam is not
90degrees (TRUE OR FALSE) - ANSWER-True


When the sound source and the receiver are not moving directly towards or
away from each other, the _________ of the angle between them enters into the
calculation of doppler shift - ANSWER-Cosine


The range equation related distance from the reflector to ________ and
________. - ANSWER-Time-of-flight, propagation speed


In soft tissue: Distance traveled = ___________ x round trip time - ANSWER-
Propagation Speed


When does pre-processing occur? - ANSWER-When the patient is scanned


Post processing occurs when the image is? - ANSWER-Entered the A/D
converter but before display


The region from the transducer to the minimum beam cross-sectional area is
the? - ANSWER-Fresnel zone


Biologic effects have not been documented below what intensity (SPTA)? -
ANSWER-100 mW/cm2

Información del documento

Subido en
24 de septiembre de 2025
Número de páginas
34
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$20.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Vendido
14
Seguidores
1
Artículos
1503
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes