Which |set |of |documentation |is |required |to |be |maintained |and |retained |for |the |life |of |the |
system?

as |built |drawings, |hydraulic |calculations, |original |acceptance |test |records, |and |device |
manufacturer's |data |sheets

as |built |drawings, |hydraulic |data |plate, |and |annual |maintenance |and |test |records

inspection |reports, |test |records, |and |maintenance |as |required |by |the |standard

installation |drawings, |permit |applications, |and |submittals |signed |by |the |Authority |Having |
Jurisdiction |(AHJ) |- | |correct |answers |a



What |provisions |must |be |made |for |a |main |drain |test?

shut |down |fire |pump

shut |down |jockey |pump

shut |down |main |control |valve

verify |adequate |drainage |- | |correct |answers |c



Which |set |of |steps |are |taken |when |an |inspector |notices |that |the |air |gauge |on |a |freezer |is |
lower |than |the |air |gauge |on |a |supply/air |compressor?

The |air |line |in |service |is |shut |down |and |the |ice |block |is |removed. |If |the |ice |block |cannot |be |
totally |removed |then |the |alternate |air |line |is |opened |and |used.

The |dry |valve |or |pre-action |system |is |shut |down |and |the |air |lines |are |dismantled |to |remove |
the |ice |block.

The |gauges |are |replaced |with |new |gauges. |If |the |gauges |still |do |not |match |pressure, |the |
alternate |air |line |is |opened |to |increase |pressure.

, The |inspector |takes |the |in-service |air |line |out |of |service |and |the |alternate |air |line |is |opened |to
|equalize |the |pressure |on |the |system. |The |out-of-service |air |line |is |taken |apart |and |the |ice |


block |is |removed |and |used |as |future |alternate |air |line. |- | |correct |answers |d?



In |a |building |with |multiple |wet |pipe |systems, |for |how |many |systems |and |at |what |frequency |
are |internal |inspections |of |piping |required?

every |other |system |every |2 |years

every |other |system |every |5 |years

every |system |every |2 |years

every |system |every |5 |years |- | |correct |answers |b



After |an |impariment |has |been |restored, |who |shall |verify |that |all |conditions |have |been |
addressed |in |order |to |remove |an |impairment |tag?

alarm |company |representative

Authority |Having |Jurisdiction |(AHJ)

fire |department |official

impairment |coordinator |- | |correct |answers |d



An |inspection |company |is |performing |its |first |inspection |of |an |existing |warehouse |owned |by |a |
new |client. |The |warehouse |has |rack |storage |with |large |sprinklers |near |the |roof. |The |spare |
sprinkler |cabinet |is |empty. |The |sprinklers |near |the |roof |are |within |20 |to |28 |inches |from |the |
top |of |the |storage.After |noting |that |the |sprinkler |cabinet |needs |to |be |replenished, |what |
should |be |recommended?

call |for |an |engineering |evaluation

have |the |storage |moved |down |to |a |36-inch |clearance

have |the |storage |moved |down |to |a |48-inch |clearance

no |further |action |is |needed; |the |head |clearance |is |correct |- | |correct |answers |a?

Información del documento

Subido en
19 de septiembre de 2025
Número de páginas
14
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
lectjones
4.0
(3)
Vendido
21
Seguidores
2
Artículos
2319
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes