NCLE Test Questions With Correct
Answers
Assessment of the quality of the peripheral curves (blends of a rigid contact lens)
| | | | | | | | | | | | | |
is achieved by the use of the-
| | | | | |
a. profile analyzer
| |
b. shadow graph
| |
c. keratometer
|
d. burton light - CORRECT ANSWER✔✔-a. profile analyzer
| | | | | | |
Contact lens power should be specified in-
| | | | | |
a. back vertex power
| | |
b. sphero-cylinder power
| |
c. power in situ
| | |
d. posterier apical radius - CORRECT ANSWER✔✔-a. back vertex power
| | | | | | | | |
The slit-lamp illumination that gives an overall view of the cornea but limits detail
| | | | | | | | | | | | |
is-
|
a. sclerotic scatter
| |
b. diffuse
|
c. specular reflection
| |
d. oscilatory - CORRECT ANSWER✔✔-b. diffuse
| | | | |
,When a keratometric miers reflected off a soft contact lens are only clear when
| | | | | | | | | | | | | |
the wearer blinks, the lens fit is too-
| | | | | | |
a. small
|
b. large
|
c. steep
|
d. flat - CORRECT ANSWER✔✔-c. steep
| | | | |
Transient keratometric mier distortion is usually due to-
| | | | | | |
a. pre-ocular tear film abnormalities
| | | |
b. prolonged rigid lens wear
| | | |
c. prolonged soft lens wear
| | | |
d. irregular corneal astigmatism - CORRECT ANSWER✔✔-a. pre-ocular tear film
| | | | | | | | | |
abnormalities
Epithelial edema which manifests itself clinically as central corneal haze, is
| | | | | | | | | | |
verified by the slit lamp using sclerotic scatter illumination. What specific
| | | | | | | | | | |
technique does the examiner use to see this condition?
| | | | | | | |
a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
| | | | | | | | | | | | | | | |
b. the blue cobalt filter of the slit lamp and an angle of about 45˚
| | | | | | | | | | | | | |
c. the green filter of the slit lamp with high magnification
| | | | | | | | | |
d. high magnification and an angle between the beam and scope of 180˚ -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-a. the naked eye and an angle between the slit lamp
| | | | | | | | | | | |
beam and the eye of 90˚
| | | | |
,With a rigid contact lens in place a flourescein pattern shows a narrow bend
| | | | | | | | | | | | | |
horizontally wih a concentration of flourescein inferiorly and superiorly under the
| | | | | | | | | |
lens. Which one of the following type of astigmatism is represented by this
| | | | | | | | | | | | | |
pattern?
a. lenticular astigmatism
| |
b. residual astigmatism
| |
c. against the rule astigmatism
| | | |
d. with the rule astigmatism - CORRECT ANSWER✔✔-d. with the rule astigmatism
| | | | | | | | | | |
Refractive Rx -3.00 -1.00 x 170 | | | | |
K's 42.00 @ 170/43.00 @ 80
| | | | |
Given the above Rx and K's he following diagnostic toric soft lens was used:
| | | | | | | | | | | | |
B.C. 8.8 |
Power -3.00 -1.00 x 180 | | | |
During dianostic evalutation, the above lens rotated 10 clockwise. The lens
| | | | | | | | | | |
ordered should have an axis of: | | | | |
a. 10
|
b. 180
|
c. 170
|
d. 160 - CORRECT ANSWER✔✔-b. 180
| | | | |
Given the same circumstances from the above question, once the correctly
| | | | | | | | | | |
ordered lens has been dispensed, the rotational marks should settle at _______.
| | | | | | | | | | |
a. 6 o clock
| | |
b. 10 clockwise rotation
| | |
, c. 10 counter clockwise rotation
| | | |
d. none of the above - CORRECT ANSWER✔✔-b. 10 clockwise rotation
| | | | | | | | | |
An instrument that allows simultaneous verification of lens diameter, optic zone
| | | | | | | | | | |
width, and peripheral curve width is:
| | | | |
a. measuring magnifier
| |
b. ophthalmometer
|
c. profile analyzer
| |
d. radiuscope - CORRECT ANSWER✔✔-a. measuring magnifier
| | | | | |
(the book says d. radiuscope)
| | | |
The instrument used for magnification of the edge of a rigid CL is a _______.
| | | | | | | | | | | | | |
a. radiuscope
|
b. shadowgraph
|
c. profile analysis
| |
d. keratometer - CORRECT ANSWER✔✔-b. shadowgraph
| | | | |
Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power
| | | | | | | | | | | | | | | | | |
of +2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her
| | | | | | | | | | | | | | | |
a new lens with a curve of 43.00, what will the new power be?
| | | | | | | | | | | | |
a. +1.50
|
b. +2.00
|
c. +2.50
|
d. +3.00 - CORRECT ANSWER✔✔-c. +250
| | | | |
Answers
Assessment of the quality of the peripheral curves (blends of a rigid contact lens)
| | | | | | | | | | | | | |
is achieved by the use of the-
| | | | | |
a. profile analyzer
| |
b. shadow graph
| |
c. keratometer
|
d. burton light - CORRECT ANSWER✔✔-a. profile analyzer
| | | | | | |
Contact lens power should be specified in-
| | | | | |
a. back vertex power
| | |
b. sphero-cylinder power
| |
c. power in situ
| | |
d. posterier apical radius - CORRECT ANSWER✔✔-a. back vertex power
| | | | | | | | |
The slit-lamp illumination that gives an overall view of the cornea but limits detail
| | | | | | | | | | | | |
is-
|
a. sclerotic scatter
| |
b. diffuse
|
c. specular reflection
| |
d. oscilatory - CORRECT ANSWER✔✔-b. diffuse
| | | | |
,When a keratometric miers reflected off a soft contact lens are only clear when
| | | | | | | | | | | | | |
the wearer blinks, the lens fit is too-
| | | | | | |
a. small
|
b. large
|
c. steep
|
d. flat - CORRECT ANSWER✔✔-c. steep
| | | | |
Transient keratometric mier distortion is usually due to-
| | | | | | |
a. pre-ocular tear film abnormalities
| | | |
b. prolonged rigid lens wear
| | | |
c. prolonged soft lens wear
| | | |
d. irregular corneal astigmatism - CORRECT ANSWER✔✔-a. pre-ocular tear film
| | | | | | | | | |
abnormalities
Epithelial edema which manifests itself clinically as central corneal haze, is
| | | | | | | | | | |
verified by the slit lamp using sclerotic scatter illumination. What specific
| | | | | | | | | | |
technique does the examiner use to see this condition?
| | | | | | | |
a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
| | | | | | | | | | | | | | | |
b. the blue cobalt filter of the slit lamp and an angle of about 45˚
| | | | | | | | | | | | | |
c. the green filter of the slit lamp with high magnification
| | | | | | | | | |
d. high magnification and an angle between the beam and scope of 180˚ -
| | | | | | | | | | | | | |
CORRECT ANSWER✔✔-a. the naked eye and an angle between the slit lamp
| | | | | | | | | | | |
beam and the eye of 90˚
| | | | |
,With a rigid contact lens in place a flourescein pattern shows a narrow bend
| | | | | | | | | | | | | |
horizontally wih a concentration of flourescein inferiorly and superiorly under the
| | | | | | | | | |
lens. Which one of the following type of astigmatism is represented by this
| | | | | | | | | | | | | |
pattern?
a. lenticular astigmatism
| |
b. residual astigmatism
| |
c. against the rule astigmatism
| | | |
d. with the rule astigmatism - CORRECT ANSWER✔✔-d. with the rule astigmatism
| | | | | | | | | | |
Refractive Rx -3.00 -1.00 x 170 | | | | |
K's 42.00 @ 170/43.00 @ 80
| | | | |
Given the above Rx and K's he following diagnostic toric soft lens was used:
| | | | | | | | | | | | |
B.C. 8.8 |
Power -3.00 -1.00 x 180 | | | |
During dianostic evalutation, the above lens rotated 10 clockwise. The lens
| | | | | | | | | | |
ordered should have an axis of: | | | | |
a. 10
|
b. 180
|
c. 170
|
d. 160 - CORRECT ANSWER✔✔-b. 180
| | | | |
Given the same circumstances from the above question, once the correctly
| | | | | | | | | | |
ordered lens has been dispensed, the rotational marks should settle at _______.
| | | | | | | | | | |
a. 6 o clock
| | |
b. 10 clockwise rotation
| | |
, c. 10 counter clockwise rotation
| | | |
d. none of the above - CORRECT ANSWER✔✔-b. 10 clockwise rotation
| | | | | | | | | |
An instrument that allows simultaneous verification of lens diameter, optic zone
| | | | | | | | | | |
width, and peripheral curve width is:
| | | | |
a. measuring magnifier
| |
b. ophthalmometer
|
c. profile analyzer
| |
d. radiuscope - CORRECT ANSWER✔✔-a. measuring magnifier
| | | | | |
(the book says d. radiuscope)
| | | |
The instrument used for magnification of the edge of a rigid CL is a _______.
| | | | | | | | | | | | | |
a. radiuscope
|
b. shadowgraph
|
c. profile analysis
| |
d. keratometer - CORRECT ANSWER✔✔-b. shadowgraph
| | | | |
Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power
| | | | | | | | | | | | | | | | | |
of +2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her
| | | | | | | | | | | | | | | |
a new lens with a curve of 43.00, what will the new power be?
| | | | | | | | | | | | |
a. +1.50
|
b. +2.00
|
c. +2.50
|
d. +3.00 - CORRECT ANSWER✔✔-c. +250
| | | | |