This study guide provides the latest EEG Board Exam questions for the 2025/2026 cycle, complete with verified correct answers. It is fully updated to reflect the current exam format and requirements, ensuring accurate and reliable preparation. With real exam-style content, this resource is ideal for focused practice and boosting confidence before the test.

Vista previa del contenido

1



EEG Board Exam 2025/2026 – Actual
Exam Questions with Verified Correct
Answers | Fully Updated Study Guide
Section 1: EEG Technical Sciences and Electrode Placement
Question 1

What is the primary physiological signal measured by an EEG?
A. Glucose metabolism rates
B. Electrical activity from cortical neurons
C. Magnetic fields produced by ion channels
D. Hemoglobin oxygenation changes

Correct Answer: B. Electrical activity from cortical neurons
Rationale: EEG records the summed electrical potentials generated by cortical neurons,
primarily pyramidal cells, through scalp electrodes. It does not measure magnetic fields (MEG),
blood oxygenation (fMRI), or glucose metabolism (PET).



Question 2

Which electrode placement system is most commonly used in clinical EEG?
A. 10–20 system
B. 12-lead system
C. International 94 system
D. 5–10 system

Correct Answer: A. 10–20 system
Rationale: The International 10–20 system is the standard for clinical EEG electrode
placement, ensuring reproducibility across recordings. The 12-lead system is used for ECG, and
the 5–10 system is a high-density variant less common in clinical practice.



Question 3

What is the normal frequency range of the alpha rhythm in adults?
A. 4–7 Hz

Page 1 of 60

, 2


B. 8–13 Hz
C. 14–30 Hz
D. 0.5–4 Hz

Correct Answer: B. 8–13 Hz
Rationale: The alpha rhythm, prominent in awake, relaxed adults with eyes closed, typically
falls between 8–13 Hz over occipital regions. Theta (4–7 Hz) and delta (0.5–4 Hz) are slower,
and beta (14–30 Hz) is faster.



Question 4

What is the minimum sampling rate required to accurately record a 70 Hz EEG signal, per the
Nyquist Theory?
A. 70 Hz
B. 100 Hz
C. 140 Hz
D. 200 Hz

Correct Answer: C. 140 Hz
Rationale: The Nyquist Theory states that the sampling rate must be at least twice the
highest frequency recorded. For a 70 Hz signal, the minimum sampling rate is 140 Hz to avoid
aliasing.



Question 5

Where should collodion and acetone be stored in an EEG lab?
A. Open shelf
B. Flammable cabinet
C. Refrigerator
D. General storage room

Correct Answer: B. Flammable cabinet
Rationale: Collodion and acetone are flammable substances requiring storage in a
designated flammable cabinet to meet OSHA safety standards.



Question 6

What are the two active ingredients in collodion used for EEG electrode application?
A. Ethanol and water

Page 2 of 60

, 3


B. Ethyl ether and ethanol
C. Acetone and saline
D. Glycerin and alcohol

Correct Answer: B. Ethyl ether and ethanol
Rationale: Collodion contains ethyl ether and ethanol, which provide adhesive properties for
securing EEG electrodes.



Question 7

What is the purpose of calibration in EEG recording?
A. To increase signal amplitude
B. To detect instrument faults and verify channel integrity
C. To reduce patient discomfort
D. To adjust electrode placement

Correct Answer: B. To detect instrument faults and verify channel integrity
Rationale: Calibration ensures EEG equipment functions correctly by comparing known
potentials and verifying that all channels amplify and filter uniformly.



Question 8

What causes over-dampening in an EEG recording, resulting in rounded waveforms?
A. High pen pressure
B. Low pen pressure
C. Incorrect filter settings
D. Faulty electrodes

Correct Answer: A. High pen pressure
Rationale: Over-dampening, caused by high pen pressure, slows the pen and produces
rounded waveforms, affecting signal clarity.



Question 9

What is the bit number for optimal resolution display in EEG systems?
A. 8 bits
B. 10 bits
C. 11 bits, preferably 12
D. 16 bits

Page 3 of 60

, 4


Correct Answer: C. 11 bits, preferably 12
Rationale: A resolution of 11–12 bits ensures sufficient detail for EEG signal display,
balancing data accuracy and storage requirements.



Question 10

Which filter settings create a very narrow band pass and should rarely be used clinically?
A. LF 1.0 Hz and HF 70 Hz
B. LF 5.0 Hz and HF 15 Hz
C. LF 0.5 Hz and HF 100 Hz
D. LF 2.0 Hz and HF 50 Hz

Correct Answer: B. LF 5.0 Hz and HF 15 Hz
Rationale: A low-frequency filter of 5.0 Hz and high-frequency filter of 15 Hz create a
narrow band pass, potentially missing critical EEG activity, and are rarely used clinically.




Section 2: EEG Patterns and Interpretation
Question 11

What activation procedure is useful for detecting absence seizures?
A. Photic stimulation
B. Hyperventilation
C. Sleep deprivation
D. Auditory stimulation

Correct Answer: B. Hyperventilation
Rationale: Hyperventilation can provoke absence seizures, characterized by 3 Hz spike-and-
wave discharges, making it a standard activation procedure.



Question 12

What activation is effective for detecting benign rolandic epilepsy?
A. Hyperventilation
B. Photic stimulation
C. Sleep activation
D. Tactile stimulation



Page 4 of 60

Información del documento

Subido en
12 de septiembre de 2025
Número de páginas
60
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$14.50

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUVIAACTUALEXAMS
3.5
(161)
Vendido
1250
Seguidores
208
Artículos
9036
Última venta
22 horas hace

Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes