• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 9 páginas
Examen

DANB RHS Exam A+ Pass Verified

Document preview thumbnail
Vista previa 2 fuera de 9 páginas

DANB RHS Exam A+ Pass Verified Unexposed Film Appearance: - Answer- clear film w/ a bluish tinge Film Exposed to White Light Appearance: - Answer- film appears black Over Exposed Film Appearance: - Answer- film appears dark Under Exposed Film: - Answer- film appears light Premolar Bite-Wing must include: - Answer- Distal 1/2 canine, all premolars present & 1st molars of the MX & MD teeth, & crestal bone Incorrect Horizontal Angulation Appearance: - Answer- overlapped contact areas appear on the film Cone-cut Appearance: - Answer- a clear, unexposed area on the film Film Bending Appearance: - Answer- film appears stretched & distorted (all or portion of film) Film Creasing Appearance: - Answer- a thin radiolucent (dark) line appears on the film (usually straight) Phalangioma Appearance: - Answer- patient's finger appears on the film image Double Exposure Appearance: - Answer- two (double) images are superimpose on top of each other Patient movement Appearance: - Answer- film image is distorted or blurred Incorrect Vertical Angulation Appearance: - Answer- short teeth w/ blunted roots appear on the film (foreshortened) Dropped Film Corner Appearance: - Answer- the occlusal plane appears tipped or tilted Incorrect Film Placement Appearance: - Answer- no apices on the film Molar Bite-Wing must include: - Answer- Distal 1/2 of second premolar, all molars present, & both MX & MD molars, & crestal bone Reversed Film Appearance: - Answer- light images w/ a herringbone pattern appear on the film X-ray Machine Purpose: (2) - Answer- 1- produce quality radiographs, 2- detection of disease & lesions for diagnostic purposes Federal Regulations- 1968: - Answer- Radiation Control for Health & Safety Act: Standardize performance of x-ray equipment Federal Regulations- 1974: - Answer- US FDA standardized all manufacturing of radiographic dental equipment (all machines must meet this) State Gov't Regulations determine when & how dental x-ray equipment is monitored: - Answer- MN- mandatory every 2 years Tube head or tube housing used to: - Answer- produce x-rays Extension arm used to: (3) - Answer- suspend tubehead, house electrical wires, & allows movement in all directions & positioning of the x-ray tubehead Control panel used to: (3) - Answer- allows for regulation x-ray beam, control electrical current for generation of X-rays, & house control buttons and settings kvP: - Answer- 65-100 kVp range- peak of enegry mA: - Answer- 7-15 range- amount Exposure time: - Answer- 1/60th of a second- standard & 1/100th of a second- digital Collimator: - Answer- lead diaphragm used to restrict the size of the x-ray beam (round, rectangular, cone) X-ray film holders: - Answer- stabe(styrofoam bite block, slimplest), XCP, Bite tab, EEZE grip, etc. Beam Alignment Device: - Answer- used to help the radiographer position the PID in relationship to the tooth and film X-ray: - Answer- beam of energy Image: - Answer- picture or likeness of an object Receptor: - Answer- something that responds to a stimulus Film Compostion: (4) - Answer- film base, adhesive layer, film emulsion, protective layer Film emulsion purpose & mixture: - Answer- to give film greater sensitivity to x-radiation, homogeneous misture of gelatin & silver halide crystals Latent Image: - Answer- stored image not visible on the film Purpose of Lead Foil Sheet: - Answer- to prevent film fogging from scatter radiation Periapical: - Answer- examines the entire tooth and surrounding structures Bitewing: - Answer- examines the interproximal surfaces of the crowns of both MX and MD teeth w/ crestal bone Occlusal: - Answer- examines large area of the MX or MD jaw Types of Intra-Oral Radiographic Examination: (3) - Answer- periapical, interpoximal, & occlusal Periapical: (Purpose, Film Type, & Technique) - Answer- used to examine the entire tooth & supporting bone, periapical film, paralleling & bisecting technique Interproximal: (Purpose, Film Type, & Technique) - Answer- examine the crown of both the mx & md teeth on a single film, & adjacent surfaces of teeth & crestal bone, bite-wing film, bite-wing technique

Vista previa del contenido

DANB RHS Exam A+ Pass Verified
Unexposed Film Appearance: - Answer- clear film w/ a bluish tinge

Film Exposed to White Light Appearance: - Answer- film appears black

Over Exposed Film Appearance: - Answer- film appears dark

Under Exposed Film: - Answer- film appears light

Premolar Bite-Wing must include: - Answer- Distal 1/2 canine, all premolars present &
1st molars of the MX & MD teeth, & crestal bone

Incorrect Horizontal Angulation Appearance: - Answer- overlapped contact areas
appear on the film

Cone-cut Appearance: - Answer- a clear, unexposed area on the film

Film Bending Appearance: - Answer- film appears stretched & distorted (all or portion of
film)

Film Creasing Appearance: - Answer- a thin radiolucent (dark) line appears on the film
(usually straight)

Phalangioma Appearance: - Answer- patient's finger appears on the film image

Double Exposure Appearance: - Answer- two (double) images are superimpose on top
of each other

Patient movement Appearance: - Answer- film image is distorted or blurred

Incorrect Vertical Angulation Appearance: - Answer- short teeth w/ blunted roots appear
on the film (foreshortened)

Dropped Film Corner Appearance: - Answer- the occlusal plane appears tipped or tilted

Incorrect Film Placement Appearance: - Answer- no apices on the film

Molar Bite-Wing must include: - Answer- Distal 1/2 of second premolar, all molars
present, & both MX & MD molars, & crestal bone

Reversed Film Appearance: - Answer- light images w/ a herringbone pattern appear on
the film

, X-ray Machine Purpose: (2) - Answer- 1- produce quality radiographs, 2- detection of
disease & lesions for diagnostic purposes

Federal Regulations- 1968: - Answer- Radiation Control for Health & Safety Act:
Standardize performance of x-ray equipment

Federal Regulations- 1974: - Answer- US FDA standardized all manufacturing of
radiographic dental equipment (all machines must meet this)

State Gov't Regulations determine when & how dental x-ray equipment is monitored: -
Answer- MN- mandatory every 2 years

Tube head or tube housing used to: - Answer- produce x-rays

Extension arm used to: (3) - Answer- suspend tubehead, house electrical wires, &
allows movement in all directions & positioning of the x-ray tubehead

Control panel used to: (3) - Answer- allows for regulation x-ray beam, control electrical
current for generation of X-rays, & house control buttons and settings

kvP: - Answer- 65-100 kVp range- peak of enegry

mA: - Answer- 7-15 range- amount

Exposure time: - Answer- 1/60th of a second- standard & 1/100th of a second- digital

Collimator: - Answer- lead diaphragm used to restrict the size of the x-ray beam (round,
rectangular, cone)

X-ray film holders: - Answer- stabe(styrofoam bite block, slimplest), XCP, Bite tab,
EEZE grip, etc.

Beam Alignment Device: - Answer- used to help the radiographer position the PID in
relationship to the tooth and film

X-ray: - Answer- beam of energy

Image: - Answer- picture or likeness of an object

Receptor: - Answer- something that responds to a stimulus

Film Compostion: (4) - Answer- film base, adhesive layer, film emulsion, protective layer

Film emulsion purpose & mixture: - Answer- to give film greater sensitivity to x-radiation,
homogeneous misture of gelatin & silver halide crystals

Información del documento

Subido en
14 de agosto de 2025
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.69

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ScholarExams
3.7
(71)
Vendido
401
Seguidores
186
Artículos
11788
Última venta
3 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes