The EC F Gas Regulations 517/2014 requires refrigeration systems containing > 50 and
< 500 of an HFC refrigerant without an automatic leak detector to be leak tested? -
CORRECT ANSWER 6 monthly

Which of the following TEV superheat settings is likely to cause refrigeration system
hermetic compressor to run continuously and overheat? - CORRECT ANSWER 20K

Under the F Gas Regulations when should a newly installed system be checked for
refrigeration leakage? - CORRECT ANSWER Immediately after being put into service

The residual flux that is left on the outside of a brazed joint must be removed because?
- CORRECT ANSWER The flux absorbs water from the air and corrodes the
pipework

What pipe diameter is least likely to fail when carrying out the strength test using OFN?
- CORRECT ANSWER 1 inch

Which one of the following effects would result in an increase in system efficiency? -
CORRECT ANSWER A reduction in vapour specific volume

The ODP of the refrigerant R22 is? - CORRECT ANSWER 0.05

What would cause a reduction in the efficiency of a cooling plant? - CORRECT
ANSWER High pressure ratio

Which one of the following would improve the energy efficiency of an air conditioning or
refrigeration system the most? - CORRECT ANSWER Lowering the condensing
temperature and raising the evaporating temperature

Why might a unit short cycle on low pressure control? - CORRECT ANSWER
Refrigerant loss

What refrigerant is covered by the requirements of EC Regulations 517/2014? -
CORRECT ANSWER R404A

What identifies that a system may have lost refrigerant? - CORRECT ANSWER
Bubbles in the sight glass

, The term indirect leak checking refers to? - CORRECT ANSWER The calculation of
the correct operating conditions by taking pressure and temperature readings

To find a suspected refrigerant leak on a freezer room evaporator it's best to? -
CORRECT ANSWER Leak test the evaporator with the unit in shut down

If the fins on the evaporator become blocked what is the result on the suction vapour? -
CORRECT ANSWER Pressure and temperature fall

To calculate the system compression ratio? - CORRECT ANSWER Divide discharge
pressure by suction pressure (gauge)

What would make ice form around a TEV and possibly cause the pipe work damage? -
CORRECT ANSWER Short of refrigerant

A refrigeration system contains a refrigerant at a dew point condition of -25 degrees,
you would like? - CORRECT ANSWER 5k of superheat

The unit measurement of specific volume as found on a pressure empathy chart is? -
CORRECT ANSWER m3/kg

Which would result in an increase in system efficiency? - CORRECT ANSWER
Reduction in specific volume at compressor inlet

Which refrigerant conditions will provide a clear liquid line sight glass? - CORRECT
ANSWER Subcooled liquid

What is reasonable condensing temperature for evaporative condensers? - CORRECT
ANSWER Air on the condenser wet bulb + 10k

What leak detection method will be ineffective on refrigeration systems charged with
zeotropic refrigerant? - CORRECT ANSWER Halide lamp

Which refrigerant has the lowest GWP? - CORRECT ANSWER R32

Using unfiltered/untreated water in a water-cooled condenser will? - CORRECT
ANSWER Raise discharge pressure and raise discharge temperature

What may cause the system to trip out on a High Pressure (HP) switch? - CORRECT
ANSWER Dirty condenser

The EC F Gas Regulations 517/2014 requires refrigeration systems containing >5 and
<50 of an HFC refrigerant without an automatic leak detector to be leak tested? -
CORRECT ANSWER 12 monthly

Información del documento

Subido en
7 de agosto de 2025
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CornelWest
3.7
(267)
Vendido
1661
Seguidores
1131
Artículos
13726
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes