• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 19 páginas
Examen

LAB 400 – Integrated Beaker Build Questions with Accurate Answers | Epic Systems | Practice Questions with Verified Solutions

Document preview thumbnail
Vista previa 3 fuera de 19 páginas

This document provides a comprehensive set of practice questions and answers related to LAB 400 and the Beaker module in Epic Systems. It includes detailed explanations of lab workflows, genetic testing methodologies (e.g., PCR, NGS, FISH), label configuration, result reporting, holds, follow-ups, and rule building. The content is especially valuable for trainees or professionals preparing for Epic certification or needing to reinforce their understanding of lab information system configuration.

Vista previa del contenido

LAB 400 - Integrated Beaker Build questions with
accurate answers
1. Extract DNA Ans✓✓✓ Add reagent to the specimen to isolate the
DNA


1. Prepare Slide Ans✓✓✓ Collect specimen and isolate the cells to fix to
a slide


2. Drop Probes Ans✓✓✓ Add fluorescent probes that are compliments to
your gene of interest


2. Polymerase Chain Reaction (PCR) Ans✓✓✓ Create many copies of
the DNA to obtain a sufficient sample size. Also called amplification


3. Barcoding/Tagging Ans✓✓✓ Attach a patient nametag at the
molecular level to the DNA strands


3. Hybridization Ans✓✓✓ Heat up the strand to allow the probe and
genome to stick if complementary


4. Library Creation Ans✓✓✓ Combine multiple patients' DNA strands
together


4. Scoring Ans✓✓✓ Two cytogenetic techs separately count the number
of colored signals which correspond to a probe-gene match under a
microscope and then compare them

,5. Ready for Review Ans✓✓✓ Cytogenetic techs interpret the meaning
of the data for the patient


5. Ready to Sequence Ans✓✓✓ Checkpoint for sequencing process to
begin. Sample goes on the instrument


6. Bioinformatic Processing Ans✓✓✓ Interface message containing raw
sequence read data is sent to a bioinformatic pipeline where patient
DNA is compared it to a known human reference sequence. Differences
are called variants, and these are interfaced back into Epic


6. Director Sign-out Ans✓✓✓ Molecular pathologist reviews and signs
out the results


7. Resulting Ans✓✓✓ Pathologists interpret the variants


8. Pathologist Sign Out Ans✓✓✓ Pathologist reviews the results and
verifies them


9. Molecular Director Review and Sign-out Ans✓✓✓ The molecular
director reviews the results and verifies them. Relevant results are sent
to the patient's chart for the provider to view


A variant is pathogentic Ans✓✓✓ If it is disease-causing

, All the chromosomes of a patient make up their Ans✓✓✓ genomes


Attaching a Rule Ans✓✓✓ - The rule's context limits where you can link
a rule
- Different rule fields require rules with different contexts


Batch Scheduler Ans✓✓✓ Includes job (E1C), batch (E1B), and run
(E1D) records which determine when the result reports are printed


Beaker Result Reports Ans✓✓✓ - Printed result reports are often
required for sending results to submitters or to affiliated physicians not
using EpicCare or EpicCare Link
- You can configure result reports based on the needs of your facility or
your submitters


Building a Rule Ans✓✓✓ - Rules are a way to build customized
conditions without needing to know how to program (condition under
which something should happen)
- Can use rules in many places in the system to allow for added
flexibility
1. Plan a Rule Build
2. Creating a Rule
3. Testing a Rule
4. Attaching a Rule

Información del documento

Subido en
29 de julio de 2025
Número de páginas
19
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
cracker
3.8
(401)
Vendido
2172
Seguidores
1346
Artículos
50097
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes