WFSM SET A VOLUME 4 URE WITH COMPLETE SOLUTIONSWFSM SET A VOLUME 4 URE WITH COMPLETE SOLUTIONSWFSM SET A VOLUME 4 URE WITH COMPLETE SOLUTIONS what type of fire suppression system has closed heads, is full of water, and under pressure at all times - ANSWER-wet pipe in a wet-pipe sprinkler system, the alarm is protected from small water surges through a - ANSWER-bypass line what is the first step in restoring a wet pipe sprinkler system - ANSWER-replace damaged heads when restoring a wet-pipe sprinkler system, any trapped air can b bled off by - ANSWER-using the inspector's test valve

Vista previa del contenido

WFSM SET A VOLUME 4 URE WITH
COMPLETE SOLUTIONS
what type of fire suppression system has closed heads, is full of water, and under
pressure at all times - ANSWER-wet pipe

in a wet-pipe sprinkler system, the alarm is protected from small water surges through a
- ANSWER-bypass line

what is the first step in restoring a wet pipe sprinkler system - ANSWER-replace
damaged heads

when restoring a wet-pipe sprinkler system, any trapped air can b bled off by -
ANSWER-using the inspector's test valve

the purpose of conducting a drain flow test on a wet pipe sprinkler system si to -
ANSWER-determine if there are partially closed valves or obstructions in the distribution
system

what should you do if false alarms are being caused by pressure surges - ANSWER-
relieve trapped air pressure

what is used to dry pipe sprinkler system to keep the clapper seated - ANSWER-air
pressure

what are the two types of quick opening devices in a large dry pipe system - ANSWER-
accelerators and exhausters

how long should it take to recharge a dry pipe system during restoration - ANSWER-30
minutes

when testing a dry-pipe fire sprinkler system, your first step is to - ANSWER-notify the
fire alarm communications center

when inspecting a dry pipe sprinkler system, record and compare to previous readings
that air and water pressure and - ANSWER-temperature

how do you correct occasional trips in dry pipe systems caused by occasional water
surges - ANSWER-increase air pressure

what are the two possible positions of the differential deluge valve - ANSWER-standby
and fire

, when a deluge fire sprinkler system is operational, the main water control valve is -
ANSWER-open and the alarm valve to control devices is open

the extinguisher system that provides the same general protection similar to that of the
foam-water system is the - ANSWER-deluge system

the foam system has an advantage because of its smothering action for class -
ANSWER-B fires

in a foam system, what is mixed with the foam to control fires - ANSWER-air

the purpose of flushing the foam system is to prevent - ANSWER-corrosion

the foam system is operational when it is in the - ANSWER-standby position

1301 Halon system will not harm personnel in concentrations below - ANSWER-10
percent

dry-chemical systems are not allowed to be used for what type of fire protection
application according to Unified Facilities Criteria (UFC) UFC 3-600-01 - ANSWER-
commercial kitchens

what are the two types of backflows - ANSWER-backsiphonage and backpressure

what re the two types of cross connection - ANSWER-direct and indirect

which term is defined as an impairment of the potable water that does not adversely
affect public health - ANSWER-pollution

what AF Form is used to inventory and list every backflow device on an installation -
ANSWER-845

what AF Form is used to sketch the exact location of all devices - ANSWER-845

what type of device is the most positive (non-mechanical) against backflow - ANSWER-
air gap

the vertical space between the supply line and the flood level rim must be at least -
ANSWER-two times the diameter of the supply pipe

what is the smallest air gap allowed to prevent basksiphonage - ANSWER-1 inch

what is the correct size air gap if the supply pipe is 2 inches in diameter - ANSWER-4
inches

Información del documento

Subido en
4 de julio de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$19.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingTutor1
3.9
(460)
Vendido
1706
Seguidores
1073
Artículos
18488
Última venta
4 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes