Warm Air Heating System Equipment In a warm air heating system the cold air return registers are located a) in exterior walls b) in interior locations c) under windows d) in floors e) in ceilings -Correct Answer B The major disadvantage of an electric resistance coil furnace for warm air heating is a) the high cost of electricity b) the danger from electric shock c) the high cost of maintenance d) the large size of the furnace e) the location of electrical wiring -Correct Answer A Lowboy furnaces are just over a) 1.0 m in height b) 0.8 m in height c) 1.4 m in height d) 1.6 m in height e) 1.2 m in height -Correct Answer E The advantage of having duct furnaces instead of a large central furnace is a) less initial cost b) easier installation c) better control of heat in each zone of the building d) that they require less space e) lower maintenance costs -Correct Answer C The power supply for an electric resistance coil furnace is a) 60 V b) 120 V c) 240 V d) 220 V e) 480 V -Correct Answer C In a fin-coil heat exchanger the primary source of heat for the exchanger is a) steam or hot water b) gas c) oil d) solar e) radiant -Correct Answer A A type of directly fired space heater is a) a unit heater b) a floor furnace c) a wall furnace d) all of the above e) none of the above -Correct Answer D High efficiency furnaces and heaters range in annual fuel utilization efficiency (AFUE) from a) 94 - 98% b) 80 - 95% c) 70 - 75% d) 60 - 70% e) 50 - 60% -Correct Answer B In high efficiency furnaces if the temperature of the flue gas drops below 65 degrees C the a) flue gas will condense b) water vapour will condense c) furnace burner will shut down d) furnace burner will start up e) furnace vent will close -Correct Answer B In a pulse combination furnace the stated efficiency is a) 94 - 98% b) 80 - 95% c) 70 - 75% d) 60 - 70% e) 50 - 60% Warm Air Furnace Components and Maintenance -Correct Answer A Heat exchangers in gas fired furnaces are made of a) brass b) copper c) aluminum d) steel e) cast iron -Correct Answer D Air filters can be divided into two groups a) mechanical and rotating drum b) electronic and steam c) dry and wet d) steam and rotating drum e) mechanical and electronic -Correct Answer E Electronic filters will remove a) all particles from the air b) fine particles from the air c) odour producing gases from the air d) smoke from the air e) all of the above -Correct Answer B The perimeter loop system of furnace ducting is ideal for a building with a) no insulation in the walls b) concrete walls c) no basement d) low head room in the basement e) no cold air returns -Correct Answer C

Vista previa del contenido

AAA Food Handler



ABSA 4b Exam Questions with Correct Detailed
Answers 100% Verified 2025
Warm Air Heating System Equipment

In a warm air heating system the cold air return registers
are located
a) in exterior walls
b) in interior locations
c) under windows
d) in floors
e) in ceilings -Correct Answer ✔B

The major disadvantage of an electric resistance coil furnace
for warm air heating is
a) the high cost of electricity
b) the danger from electric shock
c) the high cost of maintenance
d) the large size of the furnace
e) the location of electrical wiring -Correct Answer ✔A

Lowboy furnaces are just over
a) 1.0 m in height
b) 0.8 m in height
c) 1.4 m in height
d) 1.6 m in height
e) 1.2 m in height -Correct Answer ✔E

The advantage of having duct furnaces instead of a large
central furnace is
a) less initial cost
b) easier installation
c) better control of heat in each zone of the building
d) that they require less space
e) lower maintenance costs -Correct Answer ✔C

The power supply for an electric resistance coil furnace is
a) 60 V

AAA Food Handler

,AAA Food Handler


b) 120 V
c) 240 V
d) 220 V
e) 480 V -Correct Answer ✔C

In a fin-coil heat exchanger the primary source of heat for
the exchanger is
a) steam or hot water
b) gas
c) oil
d) solar
e) radiant -Correct Answer ✔A

A type of directly fired space heater is
a) a unit heater
b) a floor furnace
c) a wall furnace
d) all of the above
e) none of the above -Correct Answer ✔D

High efficiency furnaces and heaters range in annual fuel
utilization efficiency (AFUE) from
a) 94 - 98%
b) 80 - 95%
c) 70 - 75%
d) 60 - 70%
e) 50 - 60% -Correct Answer ✔B

In high efficiency furnaces if the temperature of the flue
gas drops below 65 degrees C the
a) flue gas will condense
b) water vapour will condense
c) furnace burner will shut down
d) furnace burner will start up
e) furnace vent will close -Correct Answer ✔B

In a pulse combination furnace the stated efficiency is
a) 94 - 98%
b) 80 - 95%


AAA Food Handler

,AAA Food Handler


c) 70 - 75%
d) 60 - 70%
e) 50 - 60%
Warm Air Furnace Components and Maintenance -Correct Answer ✔A

Heat exchangers in gas fired furnaces are made of
a) brass
b) copper
c) aluminum
d) steel
e) cast iron -Correct Answer ✔D

Air filters can be divided into two groups
a) mechanical and rotating drum
b) electronic and steam
c) dry and wet
d) steam and rotating drum
e) mechanical and electronic -Correct Answer ✔E

Electronic filters will remove
a) all particles from the air
b) fine particles from the air
c) odour producing gases from the air
d) smoke from the air
e) all of the above -Correct Answer ✔B

The perimeter loop system of furnace ducting is ideal for a
building with
a) no insulation in the walls
b) concrete walls
c) no basement
d) low head room in the basement
e) no cold air returns -Correct Answer ✔C

Which of the following is a type of outlet in a warm air
heating system?
a) a grill
b) a register
c) a ceiling diffuser


AAA Food Handler

, AAA Food Handler


d) a perforated panel
e) all of the above -Correct Answer ✔E

Supply outlets should always be located
a) in walls
b) in floors
c) in ceilings
d) to best prevent cold drafts
e) in baseboards -Correct Answer ✔D

In a warm air heating system, the heated air should enter the
rooms preferably via the
a) high wall registers on the inside wall
b) baseboard registers on the inside wall
c) baseboard registers on the outside wall
d) high wall registers on the outside wall
e) unit heaters on the outside wall -Correct Answer ✔C

Sleeve bearings on furnace fans require
a) no lubrication
b) grease every six months
c) a few drops of oil every six months
d) a few drops of oil monthly
e) flood lubrication -Correct Answer ✔C

Furnace heat exchangers should be checked for corrosion
because
a) carbon monoxide could leak into the building
b) the holes reduce the furnace efficiency
c) cold air could leak into the building
d) too much air would enter the furnace
e) the air will become too dry for comfortable heating -Correct Answer ✔A

Insufficient heat throughout a building is likely caused by
a) too high an air flow
b) insufficient heat input
c) poorly insulated ducting
d) a missing filter
e) poor humidity control -Correct Answer ✔B

AAA Food Handler

Información del documento

Subido en
27 de junio de 2025
Número de páginas
157
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$23.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PossibleA
3.9
(151)
Vendido
1074
Seguidores
651
Artículos
13998
Última venta
13 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes