BICSI 1 & 2

'Through' and 'membrane' are the two types of - ANS-Penetrations

[Triangle] - ANS-Work Area

0 dB = - ANS-1 mW @ 1004Hz across an impedance of 600 ohm

1 ohm of resistance will allow - ANS-one ampere of current to flow when one volt is applied

1,000 Hz is - ANS-1 kHz

1,000,000 Hz is - ANS-1MHz

1,000,000,000 Hz is - ANS-1GHz

110 frames are available in - ANS-50, 100, 300, and 900 pair count

25 Pair telephone Color Code: - ANS-White, Red, Black, Yellow, Violet

4 Pair cable - ANS-Shielded or non-shielded, 22-26 AWG, Solid conductors for Backbone or
Horizontal cabling

4P4C - ANS-Phone

6P6C - ANS-Phone and modem

8P8C - ANS-Data

A ____ is not a style of splice enclosure - ANS-Bridge

a _____ is not a 25pair modular splicing connector configuration - ANS-Butt

A B Cs - ANS-Airway, Breathing, Circulation

A power strip supporting dual-corded-equipment should be loaded to no more than ____ of the
circuit capacity - ANS-40%

Ablative - ANS-Develops a hard char

Ablative fire-stop materials - ANS-develop a hard char and become rigid

,AHJ - ANS-Athority having jurisdiction

Alien crosstalk(AXT) - ANS-Unwanted signal transfer from one pair in a cable to another pair in
another cable.

An analog signal varies in what two aspects - ANS-Amplitude and tone

An installer must be a highly skilled professional, a ____ member and _____ learner -
ANS-Team, ongoing

Analog signals - ANS-Utilize continuously varying electrical signals

ANSI/J-STD-607-A - ANS-Commercial Building Grounding and Bonding Requirements for
Telecommunications

ANSI/TIA/EIA-568-C.2 - ANS-Balanced Twisted Pair Telecommunications Cabling and
Component Standards

ANSI/TIA/EIA-568-C.3 - ANS-Optical Fiber Cabling Component Standards

ANSI/TIA/EIA-570-B - ANS-Residential Telecommunications Infrastructure Standard 2004

ANSI/TIA/EIA-606-A - ANS-Administration Standard for Commercial Telecommunications
Infrastructure

ANSI/TIA/EIA-606-A Class 1 - ANS-Building Served by single ER

ANSI/TIA/EIA-606-A Class 2 - ANS-Building served by more than one telecommunications
space

ANSI/TIA/EIA-606-A Class 3 - ANS-Multiple building at one site

ANSI/TIA/EIA-606-A Class 4 - ANS-Multiple site or campuses

Area in a Data Center that contains equipment cabinets or racks - ANS-ZDA

Area in a Data Center that contains the core LAN and SAN switches? - ANS-MDA

Area in a Data Center that contains the HC - ANS-HDA

Area in a Data Center that contains the optional interconnect where an equipment outlet or
consolidation point may be located - ANS-ZDA

, Area in a Data Center that containsthe intermediate cross-connect and possibily a second layer
backbone - ANS-IDA

ASTM - ANS-American Society of Testing Materials

Attenuation to crosstalk Ratio(ACR-F) - ANS-Derived from subtracting the insertion loss of the
distributor pair from the cable's FEXT measurement. The higher the dB the better.

AWG - ANS-American wire gauge. 36 AWG(5 mil) smallest, 4/0 AWG largest(460 mil)

Backbone Cables - ANS-Interconnect TRs, ERs, EFs.

Backbone conduits should - ANS-Terminate where they enter the TR or ER, grounding
bushings, 1-3" AFF

Balanced cable(UTP) has - ANS-same voltage on each conductor in reference to ground

Bandwidth is - ANS-The range between the highest and the lowest frequencies of a
communications component

BICSI - ANS-Building Industry Consulting Service International

BICSI recommends only _____ cables be installed inside commercial buildings - ANS-Listed

BICSI recommends what width of cable tray be mounted on backboards - ANS-12 in

Bix frames are available in - ANS-50, 250, 300, and 900 pair count

Cable trays are used - ANS-between TRs, and from TRs to work areas. Made of steel or
aluminum, styles: Tubular, solid bar, Rod.

Cabling companies depend on _____ for new and repeat business - ANS-Customers

Capacitance is - ANS-A property of conductors that allows storage of electrical charges when
potential differences exist

Capacitance is measured in - ANS-farads(micro 1/millionth, nano 1/billionth, pico 1/trillionth)

CAT3 - ANS-16 MHz

CAT5 - ANS-100 MHz

Cat5 UTP has a transmission characteristic of up to - ANS-100MHz

Información del documento

Subido en
14 de junio de 2025
Número de páginas
19
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Eduhprofe
3.5
(2)
Vendido
9
Seguidores
0
Artículos
1076
Última venta
7 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes