A system that allows an alarm to be received from either side of a single ope - Answer: Class A
primary purpose of a duct smoke - Answer: to prevent the spread of smoke within the building
Horns, Strobes, Bells, and speakers are connected to what type of circuit - Answer: Notification
appliance circuit
that all wiring is electronically monitored for disarrangement or break in cabling system - Answer:
supervised wiring
indicate that the unit is electrically safe and meets UL product standards - Answer: UL listing
provide requirements for the type of fire alarm systems in a particular occupancy type or use group -
Answer: IBC
has ability to enforce codes and standards adopted jurisdiction - Answer: fire inspector
A protected premises fire alarm system requires - hours of standby power and an additional - minutes of
alarm capacity - Answer: 24-5
in building fire emergency voice/alarm communications system hours standby and minutes of alarm -
Answer: 24-15
in buildings with mass notification hours standby and minutes of alarm - Answer: 24-15
, Wide area building Mass Notification - Answer: 7 days 60 minutes
garage attic and kitchen - Answer: areas where a smoke detector should not be used
impaired suppression system is a - Answer: supervisory
a fail safe class wiring system - Answer: class d
dedicated branch circuit, Disconnecting means marked as Fire Alarm Circuit, disconnecting means must
be marked red in color - Answer: Fire Alarm Primary Power Supply
the entire lens of a visible notification appliance must be mounted between - inches and - inches -
Answer: 80/96
Smoke detectors listed to UL 268 must actuate before the smoke density in the test box reaches -
percent per foot obstruction - Answer: 4
8 1/2 X 11 - Answer: A
11 X 17 - Answer: B
17 X 22 - Answer: C
22 X 34 - Answer: D
34 X 44 - Answer: E
thinest line weight - Answer: dimension line
it supplements drawings and has equal value - Answer: specifications
Comprehensive Questions
(Frequently Tested) with
Verified Answers
A system that allows an alarm to be received from either side of a single ope - Answer: Class A
primary purpose of a duct smoke - Answer: to prevent the spread of smoke within the building
Horns, Strobes, Bells, and speakers are connected to what type of circuit - Answer: Notification
appliance circuit
that all wiring is electronically monitored for disarrangement or break in cabling system - Answer:
supervised wiring
indicate that the unit is electrically safe and meets UL product standards - Answer: UL listing
provide requirements for the type of fire alarm systems in a particular occupancy type or use group -
Answer: IBC
has ability to enforce codes and standards adopted jurisdiction - Answer: fire inspector
A protected premises fire alarm system requires - hours of standby power and an additional - minutes of
alarm capacity - Answer: 24-5
in building fire emergency voice/alarm communications system hours standby and minutes of alarm -
Answer: 24-15
in buildings with mass notification hours standby and minutes of alarm - Answer: 24-15
, Wide area building Mass Notification - Answer: 7 days 60 minutes
garage attic and kitchen - Answer: areas where a smoke detector should not be used
impaired suppression system is a - Answer: supervisory
a fail safe class wiring system - Answer: class d
dedicated branch circuit, Disconnecting means marked as Fire Alarm Circuit, disconnecting means must
be marked red in color - Answer: Fire Alarm Primary Power Supply
the entire lens of a visible notification appliance must be mounted between - inches and - inches -
Answer: 80/96
Smoke detectors listed to UL 268 must actuate before the smoke density in the test box reaches -
percent per foot obstruction - Answer: 4
8 1/2 X 11 - Answer: A
11 X 17 - Answer: B
17 X 22 - Answer: C
22 X 34 - Answer: D
34 X 44 - Answer: E
thinest line weight - Answer: dimension line
it supplements drawings and has equal value - Answer: specifications