• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 22 páginas
Examen

Baep Exam Questions & Answers

Document preview thumbnail
Vista previa 3 fuera de 22 páginas

BAEP EXAM QUESTIONS & ANSWERS

Vista previa del contenido

BAEP EXAM QUESTIONS & ANSWERS
A - Answers :Low frequency sounds are
A- at the apex of the cochlea
B- perceived along Reissner's membrane
C- near the round window
D- near the stapes

A - Answers :Wave III of the BAEP is generated by the
A- cochlear nucleus
B- inferior colliculus
C- lateral lemniscus
D- medial geniculate

B - Answers :A rarefaction click occurs when the
A- movement of a transducer diaphragm alternates in polarity relative to the tympanic
membrane on a random basis
B- initial movement of a transducer diaphragm is away from the tympanic membrane
C- movement of a transducer diaphragm alternates in polarity relative to the tympanic
membrane every second trial
D- initial movement of a transducer diaphragm is towards the tympanic membrane

B - Answers :The masking level suggested for the elimination of crossover responses is:
A- 100 dB peSPL
B- 60 dB SPL
C- Same intensity as the click
D- 60 dB nHL

A - Answers :What problem may occur when performing intraoperative BAEPs using
compressible tubing?
A- The compressible tubing can become obstructed and obscure the sound to the ear
B- The patient's postoperative hearing can become impaired
C- Their use may cause trauma to the ear canal and should be avoided
D- A contamination of the sterile field can occur

D - Answers :An appropriate BAEP stimulation rate to avoid synchronization with 60 Hz
artifact, would be
A- 20 per second
B- 10 per second
C- 6 per second
D- 9.5 per second

D - Answers :When recording BAEPs in the OR, some auditory stimulators utilize
several inches of tubing to connect the transducer and ear inserts which:
A- do not affect the latencies of the waveforms
B- are comparable to acoustically shielded headphones

,C- delay the signal to the transducer and can cause 60 Hz artifact
D- delays the arrival of the sound to the ear and separates stimulus artifact

A - Answers :If the patients threshold is 25 dB and the stimulator is set to 85 dB, then
the intensity is
A- 60 dB SL
B- 60 dB HL
C- 110 dB SL
D- 85 dB SL

C - Answers :Increases in latency of both right and left ABR wave V of 0.9 msec in a 10
minute period would most likely indicate:
A- ambient noise
B- a "kink" in the sound delivery tubing
C- temperature effects
D- auditory nerve damage

A - Answers :ABR wave V will increase in latency about
A- 0.2 ms per degree Centigrade
B- 1.0 ms per degree Centigrade
C- 2.0 ms per degree Centigrade
D- 0.5 ms per degree Centigrade

C - Answers :ABR waveforms cannot be recorded in all of the following conditions
except:
A- intensity levels of 30 dB peSPL
B- bone drilling
C- electrode montage Fpz-A(ipsi)
D- "kinking" of the sound delivery tube

B - Answers :Increasing the BAEP rep rate from 3.4 to 31.1
A- decreased latency, increased amplitude
B- increased latency, decreased amplitude
C- decreased latency, decreased amplitude
D- increased latency, increased amplitude

B - Answers :During BAEP from posterior fossa craniotomy, if reversible loss of all ipsi
BAEP responses occurs:
A- drug effect
B- complete recovery of neuronal function
C- hypothermia
D- probable neuronal deficit post-op

B - Answers :A stimulus rate that is suitable for ABR monitoring is
A- 20
B- 31.1

, C- 81.1
D- 4.1

D - Answers :"Hearing level" (HL) is defined as the:
A- lowest intensity that an average ear drum can hear
B- inverse of the sound pressure level
C- intensity of a long duration sound that has the same amplitude as the peak SPL of a
short duration sound
D- average threshold intensity of normally hearing young adults

A - Answers :Waves III to V on the ABR are probably generated
A- at the pons-midbrain area
B- at the cortex
C- at the medulla
D- at the cerebellum

D - Answers :The sound intensity equivalent for ABR clicks that is compared to the
physical measurement of sound is:
A- dB
B- dB HL
C- dB SL
D- dB pe SPL

A - Answers :Changing from standard headphones to insert transducers connected by
plastic tubing will change the latency of wave I by about
A- +0.9 msec
B- +0.5 msec
C- +2 msec
D- -0.5 msec

A - Answers :ABR rarefaction clicks from the transducer causes
A- movement of the tympanic membrane away from the cochlea
B- movement of the tympanic membrane toward the cochlea
C- elimination of stimulus artifact
D- movement toward and away from the cochlea

D - Answers :The ABR electrode montage would include
A- CP3, CP4, Cpz
B- Fpz, CP4, CPz
C- M1, M2, Oz
D- Cz, A1, A2

D - Answers :The type of pathology that would change the ABR interpeak latencies the
greatest is
A- pathology in the middle ear
B- pathology in the cochlea

Información del documento

Subido en
3 de junio de 2025
Número de páginas
22
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(370)
Vendido
2195
Seguidores
1450
Artículos
61869
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes