◉ FP Drawing. Answer:Fire Protection Drawing. Indicates the size and route of fire suppression system piping and associated fire suppression agent heads and nozzles within the structures. ◉ M Drawing. Answer:Mechanical Drawing. Indicates the size and route of the HVAC system ducts, air handler units, chilled water piping, and refrigerant piping within the structures. ◉ P Drawing. Answer:Plumbing Drawing ◉ S drawing. Answer:Structural Drawing. A drawing that indicates the location of all components of the building structure itself. ◉ Scope of work. Answer:contract document for the project that covers the requirements for the ICT systems team. Lists all of the elements of installation and it is usually generated by the customer or the designer. ◉ T Drawing. Answer:telecommunications, security, and Audiovisual drawing. ◉ T0 Drawing. Answer:Campus or site plans ◉ T1 Drawing. Answer:Layout of complete building per floor ◉ T2 Drawing. Answer:Serving Zones ◉ T3 Drawing. Answer:Communication equipment rooms ◉ T4 Drawing. Answer:Typical detail drawings ◉ T5 Drawing. Answer:Schedules for Cutovers

Vista previa del contenido

BICSI INSTALLATION QUESTIONS AND ANSWERS ALL
CORRECT RECENT UPDATES 2025.


◉ FP Drawing. Answer:Fire Protection Drawing. Indicates the size and route of fire suppression
system piping and associated fire suppression agent heads and nozzles within the structures.


◉ M Drawing. Answer:Mechanical Drawing. Indicates the size and route of the HVAC system
ducts, air handler units, chilled water piping, and refrigerant piping within the structures.


◉ P Drawing. Answer:Plumbing Drawing


◉ S drawing. Answer:Structural Drawing. A drawing that indicates the location of all
components of the building structure itself.


◉ Scope of work. Answer:contract document for the project that covers the requirements for
the ICT systems team. Lists all of the elements of installation and it is usually generated by the
customer or the designer.


◉ T Drawing. Answer:telecommunications, security, and Audiovisual drawing.


◉ T0 Drawing. Answer:Campus or site plans


◉ T1 Drawing. Answer:Layout of complete building per floor


◉ T2 Drawing. Answer:Serving Zones


◉ T3 Drawing. Answer:Communication equipment rooms


◉ T4 Drawing. Answer:Typical detail drawings


◉ T5 Drawing. Answer:Schedules for Cutovers

, ◉ RFI Form. Answer:


◉ American Wire Gauge (AWG). Answer:A system used to provide a standard reference for
comparing various physical demensions of conductor materials. The greater the wire diameter
the smaller the AWG value.


◉ Attenuation. Answer:The decrease in magnitude or the power loss of a signal that propagates
between two points, expressed in (dB) as the ratio of received signal to transmitted signal level.


◉ Bandwidth. Answer:The information-carrying capacity of a system. Expressed in the range of
analog frequencies (e.g. 0Hz to 1 MHz) that can be transported or processed by the system.


◉ Capacitance. Answer:A property of conductors that allows storage of electrical charges when
potential differences (voltages) exist between the conductors. Measured in farads (F).


◉ Crosstalk. Answer:The unwanted transfer of a signal's electromagnetic energy from one or
more circuits to other circuits.


◉ Impedance (Z). Answer:The total opposition to current flow is called ________. Measured in
ohms.


◉ Inductance. Answer:The property of an electromagnetic field built around a conductor that
opposes any changes in current flow in a circuit, both AC and varying DC. The basic unity of
inductance is a Henry (H).


◉ Insertion loss. Answer:The measure of signal loss resulting from the insertion of a
component, or link, or channel, between a transmitter and receiver (often referred to as
attenuation).


◉ Nominal Velocity of Propagation (NVP). Answer:A ratio of the speed of transmission along a
cable relative to the speed of light in a vacuum. It is often stated in percentages.


◉ Resistance. Answer:The property of a conductor to resist the flow of electricity through it.
Expressed in ohms.


◉ Return Loss. Answer:A ratio of the power of the outgoing signal to the power of the reflected
signal. Expressed in decibels.

Información del documento

Subido en
25 de mayo de 2025
Número de páginas
13
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TopGradeInsider
4.1
(14)
Vendido
197
Seguidores
1
Artículos
63935
Última venta
4 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes