Between what percentages must you sample a concrete truck? - Answer 10% and 90% What is grab sampling? - Answer Securing at one point of the discharge as fast as possible. Tamping rod size for 100 x 200mm cylinders - Answer 10 +/- 1mm in diameter, between 450 mm and 600 mm Minimum sample required for 150 x 300mm cylinder? - Answer 30L How long do you have to obtain, transport and remix sample? - Answer 10 mins Vibration Frequency of internal vibrator - Answer 120Hz Size of internal vibrator. - Answer 20 to40mm in diameter, minimum 50mm in length. weight of mallet. - Answer 0.6 +- 0.3kg strike off bar size - Answer 6mm x 25mm x 450mm Temp of water storage tanks - Answer 23 +/- 2 Water in a storage tank must be saturated with what? - Answer calcium hydroxide minimum moist room humidity - Answer 95% Range of thermometer - Answer 0 to 50 degrees How often should a temperature recorder take a reading? - Answer 15min How often should temperature recorder be checked to make sure it'd working? - Answer Every 6 months

Vista previa del contenido

CCIL Prep Exam Questions With
Guaranteed Pass Solutions 2025.
Sampling from a mixer/truck agitator- Where is sample taken? - Answer Between 10% and
90% (Not when testing with Super P)



How is a sample taken when sampling plastic concrete? - Answer Either pass a receptacle
completely through a discharge stream OR divert a discharge stream completely into a sampling
container.



How many grab samples are needed when testing for uniformity of samples? - Answer 3



What size sample is needed when casting 3 100mm x 200mm cylinders? - Answer Minimum
20L



What size sample is needed when casting 150mm x 300mm cylinders? - Answer Minimum 30L



What size sample is needed when casting 150mm x 150mm x 535mm beams? - Answer
Minimum 55L



How much extra sample is needed when more than 3 cylinders/specimens are to be cast? -
Answer Volume of the cylinders/specimens plus 10% extra



How much time is allowed for obtaining, transporting and remixing the sample? - Answer 10
minutes



If A sample contains aggregate larger than that appropriate for the size of the moulds or
equipment. - Answer It must be wet-sieved prior to testing



Information required on reports - Answer Conc mix no, Sample source, Batch time/date,
Sample time/date, Project site, Sample location if different, Location of conc in structure,
Technician name, Lab name/address, Signature of test report reviewer, Any deviation from test
procedures

, What is Slump - Answer A measure of consistency of freshly mixed hydraulic cement concrete,
equal to the subsidence, measured to the next 5mm, of the moulded substance immediately
after the removal of the slump cone



Slump Flow - Answer The horizontal spread of concrete immediately upon removal of the
slump cone as a measure of the unconfined fluidity of concrete giving a relative degree of
indication of the degree to which concrete can travel



How many water-to-cementing materials ratios are needed for concrete trial mixes? - Answer
3



What temperature is considered stable before mixing concrete? - Answer 23 C +/- 2 C



Where should cementing materials be stored? - Answer In a dry place, in moisture-proof
containers



How much time is spent mixing concrete? - Answer Mix 3 minutes, rest 3 minutes, mix 2
minutes



Which sample can be re-used for casting cylinders? - Answer Slump or slump flow, NOT air.
Must be remixed into batch first



Cylinder mould material requirements - Answer Must have nonabsorbent surfaces and be
sufficiently rigid- Must be coated with mineral oil



Cardboard moulds cannot be used for what strength? - Answer Greater than 35MPa



Flexural mould requirements - Answer Must be rectangular and 50mm longer than the
prescribed span. Must be watertight and rigid, nonabsorbent. Variation from specified cross-
section is not to exceed 3mm. Coat with mineral oil.



Tamping Rod for 100mm x 200mm cylinders - Answer Diameter 10mm +/- 1mm and a Length
of 450mm to 600mm. One end must be hemispherical.



Tamping Rod for cylinders 150mm or greater, and rectangular moulds - Answer Diameter

Información del documento

Subido en
15 de mayo de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
COCOSOLUTIONS
4.1
(39)
Vendido
241
Seguidores
16
Artículos
10009
Última venta
8 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes