CORRECT 100%
According to NRCA roofing manual: steep-slope roof systems, what is recommended
nail spacing to fasten battens to the deck? - ANSWER 12"
According to OSHA, a toeboard shall be required along the edge of platforms more than
______ above lower levels for a distance sufficient to protect employees below. -
ANSWER 10 feet
What is the recommenced weight for copper standing seams roofs with widths between
seams of excess of 20"? - ANSWER 20 oz
The NRCA recommends that polyvinyl chloride sheet roofing comply with which ASTM
standard? - ANSWER ASTM D 44434
Spray Polyurethane Foam (SPF) roofing systems require a protective surfacing for all of
the following reasons except: - ANSWER provide walkways for four traffic
Drip Edges shall be mechanically fastened at _____ on center. - ANSWER 12"
Type I asphalt has a minimum ductility of _______ centimeters. - ANSWER 10.0
According to roofing construction and estimating, when flashing a vent pipe on a
concrete tile over an unsealed underlayment system extend the flange of the lead vent
jack under the tile course immediately _______ the pipe. - ANSWER above
All SBS polymer modified asphalt coated base sheets are suitable for use as a -
ANSWER base sheet in the installation of a multiple ply polymer modified membrane
system
The dew point is the temperature at which water vapor will_______. - ANSWER
condense
What is the temperature at which bitumen attains the proper viscosity for built up
membrane application called? - ANSWER equiviscous temperature
If wood battens are not raised to allow for drainage they should be no longer than
________ with approximately 1/2" separation between ends to help drain moisture that
may migrate into the roof system. - ANSWER 4 feet
According to roofing construction and estimating, a roofing felt installed on the outside
of an exterior wall is typically _______times more permeable than a vapor barrier
installed on the inside of an exterior wall. - ANSWER 5
, The NRCA recommends that ______ roofing asphalt be used for slopes greater than
1:12. - ANSWER Type IV
What type of flashing should be installed where the rake of the roof meets a vertical
wall? - ANSWER step flashing
What is the minimum roof slope for metal shingles in hurricanes zones? - ANSWER 4 in
12
According to roofing construction and estimating, what is the typical width of tapered
rigid insulation? - ANSWER 24"
Flat seams roofs that exceed 30 feet in any direction should be divided into sections
with a maximum width of ________ feet to accommodate expansion. - ANSWER 30
What is the quantity of 10" x 8" 3/16" thick pieces of slate per square? Allow a 3"
headlamp and 3-1/2" exposure. - ANSWER 515
What is the recommended end lap for single layer applications of mechanically attached
underlayment in tile roof systems? - ANSWER 4"
According to roofing construction and estimating, what is the minimum softening point
for Type I asphalt? - ANSWER 135 degrees F
According to the architectural sheet metal manual, cleats shall be spaced ______ on
center in an open type valley. - ANSWER 24"
What is the minimum slope lapped, non-soldered metal roofs without applied lap
sealant? - ANSWER 3:12
How far above the upper landing surface should be portable ladder side rails extend? -
ANSWER 3 feet
Manufactured tampered roof insulation is installed for the purpose of - ANSWER
creating a slope to the drain and eaves
According to the NRCA, butyl rubber waterproofing membranes should generally not be
installed when the substrate surface temperature is below: - ANSWER 40 degrees F
A toe board shall be erected along the edge of scaffold platforms more than ______
above lower levels for a distance sufficient to protect employees below. - ANSWER 10
feet
Each wood shake shall be attached with a minimum of _____ fasteners. - ANSWER 2