Which of the following lamps provides a continuous spectrum of radiant energy in the visible, near IR and near UV regions of the spectrum? correct answers Tungsten filament Which of the following isolates light within a narrow region of the spectrum? correct answers Monochromator Which of the following is not descriptive of a photomultiplier tube? correct answers Cannot be used with a chopper Which of the following is false about a photomultiplier tube? correct answers Is composed of an iron plate and a layer of selenium Which type of photodetector employs a linear arrangement that allows it to respond to a specific wavelength resulting in complete UV visible spectrum analysis? correct answers Photodiode array When performing spectrophotometer quality assurance checks, what is the holmium oxide glass filter used to assess? correct answers Wavelength accuracy In spectrophotometric analysis, what is the purpose of the reagent blank? correct answers Correct for color contribution of the reagents In regard to bichromatic analysis, which of the following is false? correct answers Absorbance is measured at the spectral absorbance peak for a blank and the sample using the same wavelength The bandpass of a spectrophotometer is 10 nm. If an instrument is set at 540 nm, the wavelengths that are permitted to impinge on the sample will be within what wavelength range? correct answers 535 to 545 nm

Vista previa del contenido

MLS Chemistry Exam || solved correctly.

Which of the following lamps provides a continuous spectrum of radiant energy in the visible,
near IR and near UV regions of the spectrum? correct answers Tungsten filament


Which of the following isolates light within a narrow region of the spectrum? correct answers
Monochromator


Which of the following is not descriptive of a photomultiplier tube? correct answers Cannot be
used with a chopper


Which of the following is false about a photomultiplier tube? correct answers Is composed of an
iron plate and a layer of selenium


Which type of photodetector employs a linear arrangement that allows it to respond to a specific
wavelength resulting in complete UV visible spectrum analysis? correct answers Photodiode
array


When performing spectrophotometer quality assurance checks, what is the holmium oxide glass
filter used to assess? correct answers Wavelength accuracy


In spectrophotometric analysis, what is the purpose of the reagent blank? correct answers Correct
for color contribution of the reagents


In regard to bichromatic analysis, which of the following is false? correct answers Absorbance is
measured at the spectral absorbance peak for a blank and the sample using the same wavelength


The bandpass of a spectrophotometer is 10 nm. If an instrument is set at 540 nm, the
wavelengths that are permitted to impinge on the sample will be within what wavelength range?
correct answers 535 to 545 nm

,Which of the following formulas is an expression of the Beer Lambert law that is routinely
applied to spectrophotometric analysis? correct answers Au X Cs / As = Cu


In spectrophotometry, which of the following is a mathematical expression of the relationship
between absorbance and transmittance? correct answers A = 2 - log % T


Which of the following is not a problem inherent in turbidimetry? correct answers Need to
maintain a constant and specific temperature


Which of the following may be associated with reflectance spectrophotometry as it relates to the
dry reagent slide technique? correct answers Unabsorbed, reflected light detected by
photodetector


Fluorometers are designed so that the path of the exciting light is at a right angle to the path of
the emitted light. What is the purpose of this design? correct answers Prevent excitation light
from reaching the detector


Which of the following represents a primary advantage of performing fluorometric over
absorption spectroscopic methods of analysis? correct answers Increased specificity and
increased sensitivity


Which of the following may be associated with fluorescence polarization? correct answers Plane
polarized light is used for sample excitation


Which of the following may be associated with bioluminescence? correct answers Light
emission produced due to enzymatic oxidation of a substrate


Nephelometry is based on the measurement of light that is: correct answers Scattered by particles
in suspension

,Which of the following instruments is used in the clinical lab or in reference labs to detect beta
and gamma emissions? correct answers Scintillation counter


Which of the following best describes chemiluminescence? correct answers Chemical energy
excites electrons that emit light upon return to ground state


In assaying an analyte with a single beam atomic absorption spectrophotometer, what is the
instrument actually measuring? correct answers Intensity of the beam from the hollow cathode
lamp after it has passed through the analyte containing flame


What is the function of the flame in atomic absorption spectroscopy? correct answers Bring the
metal analyte to its ground state


Most atomic absorption spectrophotometers incorporate a beam chopper and a tuned amplifier.
The purpose of these components is to avoid errors that would be caused by: correct answers
Measurement of light emitted by the analyte


In potentiometry, which of the following is considered the standard electrode? correct answers
Hydrogen electrode


In an electrolytic cell, which of the following is the half cell where reduction takes place? correct
answers Cathode


Mercury covered by a layer of mercurous chloride in contact with saturated potassium chloride
solution is a description of which of the following types of electrodes? correct answers Calomel


When a pH sensitive glass electrode is not actively in use, in what type of solution should it be
kept? correct answers The medium recommended by the manufacturer

, When measuring K positive with an ion selective electrode by means of a liquid ion exchange
membrane, what antibiotic will be incorporated into the membrane? correct answers
Valinomycin


Which of the following is false about ion selective electrode analysis of sodium? correct answers
Membrane coated with valinomycin


What are the principles of operation for a chloride analyzer that generates silver ions as part of
its reaction mechanism? correct answers Amperometry and coulometry


When quantifying glucose using an amperometric glucose electrode system, which of the
following is not a component of the system? correct answers Hexokinase reacts with glucose


To calibrate the pH electrode in a pH blood gas analyzer, it is necessary that: correct answers
Two buffer solutions of known pH be used


The measurement of CO2 in blood by means of a PCO2 electrode is dependent on the: correct
answers Change in pH because of increased carbonic acid in the electrolyte surrounding the
electrodes


The measurement of oxygen in blood by means of a PO2 electrode involves which of the
following? correct answers Direct relationship between amount of oxygen in the sample and
amount of current flowing in the measuring system


Which of the following blood gas parameters are measured directly by the blood gas analyzer
electrochemically as opposed to being calculated by the instrument? correct answers pH, PCO2,
PO2


Which of the following statements is false about anodic stripping voltammetry (ASV)? correct
answers Based on potentiometry

Información del documento

Subido en
10 de mayo de 2025
Número de páginas
49
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$16.19

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SirAnton
3.7
(118)
Vendido
807
Seguidores
438
Artículos
40068
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes