S-12 CITYWIDE SPRINKLER SYSTEMS 2025/2026 QUESTIONS WITH ANSWERS RATED A+ the cof holder shall know the location of all sprinkler heads, control valves, supply lines and _________ rooms. - compactor a sign indicating the location of all _______ shall be kept in the compactor room. - control valves all indicating valves in the compactor sprinkler system shall be ________ open. - sealed a minimum of _________ extra sprinkler heads with the appropriate wrenches shall be available to replaced damaged ones - 6 the cof holder shall conduct an inspection of the entire sprinkler system at least __________. - once a month automatic ball drip devices shal

Vista previa del contenido

S-12 CITYWIDE SPRINKLER SYSTEMS 2025/2026
QUESTIONS WITH ANSWERS RATED A+
✔✔the cof holder shall know the location of all sprinkler heads, control valves, supply
lines and _________ rooms. - ✔✔compactor

✔✔a sign indicating the location of all _______ shall be kept in the compactor room. -
✔✔control valves

✔✔all indicating valves in the compactor sprinkler system shall be ________ open. -
✔✔sealed

✔✔a minimum of _________ extra sprinkler heads with the appropriate wrenches shall
be available to replaced damaged ones - ✔✔6

✔✔the cof holder shall conduct an inspection of the entire sprinkler system at least
__________. - ✔✔once a month

✔✔automatic ball drip devices shall be installed in the _________ position. -
✔✔horizontal

✔✔if the sprinkler sys. Is supplied from public water main, the control valve sign may
read ________________. - ✔✔"shutoff for sprinkler sys. Located 6 feet from this sign"

✔✔gate valves of the non-indicating type are called ________. - ✔✔curb valves

✔✔in an outside stem and yolk valve (os&y), valve position is indicated by the position
of the ____________. - ✔✔stem

✔✔on a post indicator valve (piv), the position of the valve is shown through a
___________. - ✔✔telltale

✔✔fdny connections to automatic sprinkler systems shall be painted ___________. -
✔✔green

✔✔fdny connections to non-automatic sprinkler systems shall be painted ___________.
- ✔✔silver

✔✔fdny connections to standpipe systems shall be painted ____________. - ✔✔red

✔✔fdny connections to a combined standpipe/sprinkler system shall be painted
___________. - ✔✔yellow

, ✔✔fdny connections shall be fitted with a lower check valve. This will prevent ________
of water. - ✔✔backflow

✔✔pressure tanks should be kept ________ full and be maintained at or above
________ psi. - ✔✔2/3, 75

✔✔___________ are designed to take water from a supply and discharge it under
pressure. - ✔✔fire pumps

✔✔automatic fire pumps are usually needed where a ___________ may occur
immediately. - ✔✔high water demand

✔✔water alarms serve as fire extinguishing systems and serve as a(n) _________. -
✔✔automatic fire alarm.

✔✔sprinkler systems are required to have an approved motor gong, bell, horn, or
________. - ✔✔siren

✔✔sprinklers manufactured after 1/1/2000 are required to have a _____________. -
✔✔sprinkler identification number (sin)

✔✔_________ sprinklers have been recalled. - ✔✔cycling

✔✔sprinkler heads exposed to ___________ conditions are often covered with a coat of
wax, or lead. - ✔✔corrosive

✔✔at a distance of 4 feet below the deflector, the spray pattern covers a diameter of
_________ feet when discharging at 15 gpm. - ✔✔16

✔✔large drop sprinkler heads are used to break through the strong __________ of high
challenge fires. - ✔✔updrafts

✔✔if a fire has been completely extinguished, the __________ or their representative
may close the control valve. - ✔✔building owner

✔✔build up of foreign materials on sprinkler heads is commonly called _________. -
✔✔loading

✔✔spare sprinklers shall be kept at the facility when the temperature does not exceed
_________. - ✔✔100 degrees fahrenheit

Información del documento

Subido en
6 de mayo de 2025
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK
3.5
(41)
Vendido
287
Seguidores
11
Artículos
36004
Última venta
6 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes