S-12 CITYWIDE SPRINKLER SYSTEMS TEST PAPER 2025/2026 QUESTIONS WITH ANSWERS RATED A+ facilities with less than 300 sprinklers require __________ spares to be available. - 6 facilities with 301-1000 sprinklers require ________ spares to be available. - 12 facilities with over 1000 sprinklers require ________ spares to be available. - 24 pressure tank temperatures shall be kept at or above _________. - 40 degrees fahrenheit the maximum gross capacity of pressure tanks is _________ gallons. - 9000 primary water pressure tanks shall be equipped with two _____________. - high and low alarm systems pressure tanks may be supervised by an approved ________ company which monitors the entire sprin

Vista previa del contenido

S-12 CITYWIDE SPRINKLER SYSTEMS TEST PAPER
2025/2026 QUESTIONS WITH ANSWERS RATED A+
✔✔facilities with less than 300 sprinklers require __________ spares to be available. -
✔✔6

✔✔facilities with 301-1000 sprinklers require ________ spares to be available. - ✔✔12

✔✔facilities with over 1000 sprinklers require ________ spares to be available. - ✔✔24

✔✔pressure tank temperatures shall be kept at or above _________. - ✔✔40 degrees
fahrenheit

✔✔the maximum gross capacity of pressure tanks is _________ gallons. - ✔✔9000

✔✔primary water pressure tanks shall be equipped with two _____________. - ✔✔high
and low alarm systems

✔✔pressure tanks may be supervised by an approved ________ company which
monitors the entire sprinkler system. - ✔✔central station

✔✔__________ tanks are made of wood, steel, or concrete. - ✔✔gravity

✔✔gravity tanks should be at least ________ feet above the highest line of sprinkler
heads. - ✔✔25

✔✔for every 1 foot the tank is above the discharge outlet ___________ psi of pressure
is generated. - ✔✔0.433

✔✔automatic fill pumps fill the tank at a rate of _________ gpm or more. - ✔✔65

✔✔the _______ turn on the fill pump when the water in the tank is too low. - ✔✔floats

✔✔some methods to prevent ice inside a gravity tank are _________. - ✔✔circulated
hot water, steam, steam coils, and sun heat

✔✔the main reason a sprinkler sys. Supplied by a gravity tank fails is __________. -
✔✔not enough water in the tank

✔✔the __________ pump is the standard pump currently used in fire protection
systems. - ✔✔centrifugal

, ✔✔the water available to the centrifugal pump must always be ___________. -
✔✔under pressure

✔✔centrifugal pumps are capable of discharging water from ____________ to
_________ gpm. - ✔✔25, 5000

✔✔a vertical turbine pump is used to draw water from a well to ___________. - ✔✔fill a
storage tank.

✔✔mud, gravel, and leaves may cause damage to the ___________. - ✔✔pump

✔✔when ____________ are installed, they are usually used in combination with a
gravity tank or a pressure tank. - ✔✔manually activated pumps

✔✔cof holders should manually activate the fire pumps iaw ___________. -
✔✔manufacturer instructions

✔✔remote pushbuttons are used to __________ the pump only. - ✔✔start

✔✔pressure maintenance pumps (jockey pumps) are used to __________ pressure in
the system. - ✔✔restore

✔✔the _________ pump increases pressure to an acceptable level. - ✔✔booster

✔✔the temperature in the pump room should be maintained above __________. -
✔✔40 degrees fahrenheit

✔✔missing or defective pipe hangers can cause the system to fail due to
______________. - ✔✔pipe rupture

✔✔__________ shall not be used to fasten the system or building attachments to the
structure. - ✔✔nails

✔✔visual inspection of hanging and bracing is not required for piping concealed above
__________. - ✔✔ceilings

✔✔____________ lines are directly connected to sprinkler heads. - ✔✔branch

✔✔_________ are able to supply feed mains or cross mains directly. - ✔✔risers

✔✔standard steel pipe with diameters of 1-1/14 inch require hangers to be placed
__________ feet apart. - ✔✔12

Información del documento

Subido en
6 de mayo de 2025
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK
3.5
(41)
Vendido
287
Seguidores
11
Artículos
36004
Última venta
6 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes