S95 Practice Test Study Guide 100%
Verified.
Accessibility - Answer✔as defined in NPFA admitting close approach:not gaurded by locked
doors, elevation, and other effective means
Alarm Notification Appliance - Answer✔A fire alarm system component, such as a bell, horn,
speaker, light, text display or vibration device that issues an audible, tactile, and/or visual alert
Alarm Signal - Answer✔A signal indicating an emergency requiring immediate action, such as a
signal indicative of fire.
Annunciator - Answer✔A unit containing one or more indicator lamps, alphanumeric displays,
or other equivalent means in which each indication provides status information about a circuit,
condition or location.
Approved Central Station Company - Answer✔A central station company that has been issued a
valid certificate of operation from FDNY.
ARCS (Auxiliary Radio Communication System) - Answer✔In-Building Emergency Radio
coomunication system. ARC system is a wireless two-way building communication system for
fire department use only
central station - Answer✔A facility that receives alarm signals from a protected premises and
retransmits or otherwise reports such alarm signals to the department
1
, ©JASONMcCONNELL 2025 ALL RIGHTS RESERVED
Defined Fire Alarm System - Answer✔A fire alarm system or any sub-system thereof that
automatically transmits signals to the department or a central station and that is installed in
premises which are required to have a fire alarm system.
Designated Representative - Answer✔A person or entity designated by the subscriber who shall
be responsible for receiving notifications from the central station company concerning the
status of the protective signaling system at the protected premises and who is authorized to
take action with respect to such system.
Fire alarm control unit or panel(FACP,FCS) - Answer✔System component that receives input
from automatic and manual fire alarm devices and may provide power to detection devices or
communication devices.
Fire Alarm Signal - Answer✔A signal initiated by a fire alarm-initiating device such as a manual
fire alarm box (pull station), automatic fire detector, water-flow switch, or other device whose
activation is indicative of the presence of a fire or fire signature.
Elevator lobby smoke Detector - Answer✔Are smoke detectors thtat when activated will recall
elevators automatically into the designated landing
Duct smoke detectors - Answer✔Smoke detectors that sample the air moving through the air
distribution system ductwork or plenum; upon detecting smoke, the detector sends a signal to
shut down the air distribution unit, close any associated smoke dampers, or initiate smoke
control system operations.
Nuisance Alarm - Answer✔A fire alarm signal caused by malfunction or improper operation of a
fire alarm system or component.
Initiating device - Answer✔A system component that originates transmission of a change-of-
state condition, such as in a smoke detector, manual fire alarm box, or supervisory switch.
2