• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 7 páginas
Examen

Atomic Absorption Spectroscopy Final Exam Guide With Complete Solutions.

Document preview thumbnail
Vista previa 2 fuera de 7 páginas

Application - correct answer - water quality analysis of groundwater samples -chemical analysis of rocks, oil stream sediment samples from exploration and mapping programs Extremely sensitive, and can detect minute amounts of analyte in sample. • Because of its sensitivity, sample preparation represent the most challenging aspect of its analytical methodology. • Operation and reporting requires good training that include safety. • Measure atomic species in sample, large number of atoms in the periodic table can be analyzed. • Samples are diluted with appropriate solvent chemical application - correct answer Trace elements measurements in blood and tissue • Used in diagnostics industry as reference method for minerals calibrators assignment and standardization Theory - correct answer • The technique makes use of absorption spectrometry to assess the concentration of an analyte in a sample. The technique relies on Beer-Lambert law. • The electrons of the atoms in the atomizer can be promoted to higher orbital for a short amount of time by absorbing a set quantity of energy (i.e. light of a given wavelength). This amount of energy is specific to a particular electron transition in a particular element, and in general, each wavelength corresponds to only one element. This gives the technique its elemental selectivity. typical design of instrument - correct answer Source== Flame== Monochromator ===Detector Sample and Nebulizer (upward arrow towards the middle of flame and monochromator) atomic emission spectra - correct answer • Atomic species commonly generate line spectra as a result of electronic transitions • No superimposition of rotational and vibrational states • Intensity of the line indicates probability of the transition Doppler broadening concept - correct answer explain how the wavelength of radiation may affect the broadening of the atomic spectrum. No broadening will happen if the atom is moving in a perpendicular direction. Atom travelling towards the detector will have decreased wavelength of radiation etc. sources - correct answer Common sources are hollow cathode lamp and the electrodeless discharge lamp Because atoms generate line spectra, a line rather than a continuous source must be used hallow cathode lamp - correct answer Glass cylinder with a quartz window at one end. Inside the envelope there is anode(+) and a cup shaped cathode(-). Cathode surface is coated with a thin layer of the element to be measured. The lamp is filled with argon.. Which will become ionized Ar+ and attracted to the cathode. This can be single element or multiple element lamp. electrode discharge lamp - correct answer • This usually consist of a quartz tube surrounded by a radio frequency coil. The envelope is filled with argon gas and a vapor of the element of interest. flame atomizer - correct answer nebulizer • The process involves aspiring the sample solution into the flame. • The nebulizer is used to convert the solution into an aerosol of fine droplets • Once in flame the solution evaporates and leave the solid materials (consider Zinc Nitrate) • In ZnNO3 case this will break into Zn and NO3 free radicals via homolytic bond breaking, or hetrolyticlly into ionic species. types of flame atomizer - correct answer • Common type of flame atomizer is a laminar flow (turbulent flow) burner assembly. Has vacume system to draw the sample through small capillary tube and direct into the mixing chamber. flame characteristics - correct answer • Flame is usually very thin • Air or nitrous oxide is used as oxidants. • Acetylene is most commonly used as fuel which provide much hotter flame than the air/propane and produce greater dissociation of analyte. • All flames have zones of different temperature. outer blue area is hotter because of oxygen supply inner zone is relatively less hotter because of unburned gases • When sample containing analyte such as NaCl aspirated into the flame directly in area above burner head which is usually less hot. This will cause the solvent to evaporate in this zone. • In the next zone dissociation of analyte into ground state atoms will occur. This is the best area to focus the flame. Most of AASs have adjustable flame. • Major problem with any flame is the background emission due to reactions occurring with flame causing interference. In flames (matrix) CO, CO2, hydroxyl (OH), from water and carbon radicals generate their own emissions producing a spectra interference. This can be eliminated by: • Use of Secondary wavelength for the analysis. • Use of electro thermal analytical technique in place of flame. • Us of alternative technique for the measurement of analyte.

Vista previa del contenido

Atomic Absorption Spectroscopy
Application - correct answer - water quality analysis of groundwater samples

-chemical analysis of rocks, oil stream sediment

samples from exploration and mapping programs

Extremely sensitive, and can detect minute amounts of

analyte in sample.

• Because of its sensitivity, sample preparation represent

the most challenging aspect of its analytical

methodology.

• Operation and reporting requires good training that

include safety.

• Measure atomic species in sample, large number of

atoms in the periodic table can be analyzed.

• Samples are diluted with appropriate solvent



chemical application - correct answer Trace elements measurements in blood and
tissue

• Used in diagnostics industry as reference method for

minerals calibrators assignment and standardization



Theory - correct answer • The technique makes use of absorption spectrometry to

assess the concentration of an analyte in a sample. The

technique relies on Beer-Lambert law.

• The electrons of the atoms in the atomizer can be

promoted to higher orbital for a short amount of

time by absorbing a set quantity of energy (i.e.

light of a given wavelength). This amount of

, energy is specific to a particular electron

transition in a particular element, and in general,

each wavelength corresponds to only one

element. This gives the technique its elemental

selectivity.



typical design of instrument - correct answer Source==> Flame==> Monochromator
===>Detector

Sample and Nebulizer (upward arrow towards the middle of flame and monochromator)



atomic emission spectra - correct answer • Atomic species commonly generate line

spectra as a result of electronic transitions

• No superimposition of rotational and

vibrational states

• Intensity of the line indicates probability of

the transition



Doppler broadening concept - correct answer explain how the wavelength of
radiation may affect the broadening of the atomic spectrum.

No broadening will happen if the atom is moving in a

perpendicular direction.

Atom travelling towards the detector will have decreased

wavelength of radiation etc.



sources - correct answer Common sources are hollow cathode lamp

and the electrodeless discharge lamp

Because atoms generate line spectra, a

line rather than a continuous source must

be used

Información del documento

Subido en
25 de abril de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
RealGrades
4.0
(27)
Vendido
202
Seguidores
52
Artículos
12412
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes