• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 10 páginas
Examen

Virginia Home Improvement Contractor Exam With Verified Answers For A Guaranteed Pass

Document preview thumbnail
Vista previa 2 fuera de 10 páginas

VIRGINIA HOME IMPROVEMENT CONTRACTOR EXAM WITH VERIFIED ANSWERS FOR A GUARANTEED PASS What is directly affected by the surface and subsurface conditions of the building site? Foundations - While the type and size of a structure will partly determine the type of foundation, the foundation itself is very much affected by the surface and subsurface conditions of the building site. What term is used to describe the act of removing air pockets from setting concrete? Vibrating Concrete - Consolidation is a process that removes air pockets and forces the concrete into all parts of the forms. Which of the following is not a part of a masonry arch? Radius Anchor bolts should be spaced no more than __' apart and no more than __" from the ends of any plate section or wall corner. Each bolt must extend at least __" into the concrete. 6, 12, 7 In Southern Coastal areas, where should the vapor barrier be placed? The exterior of the wall. If butt joints occur when applying gypsum panels to wood and steel framing stagger and locate them as far from the ___ of walls and ceilings as possible. Center A minimum temperature of ___ should be maintained during gypsum board application. 50°F What is the maximum allowable span for cold-formed steel joists size 800S162-43 loaded with a live load of 40 PSF and spaced 16 inches OC? 13′-5″ What is the recommended spacing at all panel edge and end joints when positioning plywood subfloor? 1/8" Which of the following is NOT a purpose of wall sheathing? It helps distribute structural loads that do not fall directly over studs. What is the minimum clearance between the stopping point of a built-up girder and the masonry pocket? 1/2" A deck attached to the back of a house is framed with southern pine 2x10s. The joists are 16 inches OC. What is the maximum allowable clear span for the joists supporting this deck? 14 feet 0 inches Openings which provide access to all under-floor spaces through a perimeter wall shall be not less than inches. 16 X 24 Which type of building material allows water vapor to pass through but not water? Housewrap Opening for under-floor space vents must be covered with material with a least dimension of? 1/4" The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere inches cannot pass through. 6 What is the typical height of a regular base kitchen cabinet? 34-1/2" Handrails on a ramp adjacent to a wall must have a space of not less than inches between the wall and the handrails. 1.5 A nosing projection not less than inch(es) but not more than inch

Vista previa del contenido

VIRGINIA HOME
IMPROVEMENT CONTRACTOR
EXAM WITH VERIFIED
ANSWERS FOR A
GUARANTEED PASS 2024-2025

What is directly affected by the surface and subsurface conditions of the
building site?

Foundations - While the type and size of a structure will partly determine the
type of foundation, the foundation itself is very much affected by the surface
and subsurface conditions of the building site.




What term is used to describe the act of removing air pockets from setting
concrete?

Vibrating Concrete - Consolidation is a process that removes air pockets and
forces the concrete into all parts of the forms.




Which of the following is not a part of a masonry arch?

Radius




Anchor bolts should be spaced no more than __' apart and no more than __"
from the ends of any plate section or wall corner. Each bolt must extend at
least __" into the concrete.

, 6, 12, 7




In Southern Coastal areas, where should the vapor barrier be placed?

The exterior of the wall.




If butt joints occur when applying gypsum panels to wood and steel framing
stagger and locate them as far from the ___ of walls and ceilings as possible.

Center




A minimum temperature of ___ should be maintained during gypsum board
application.

50°F




What is the maximum allowable span for cold-formed steel joists size
800S162-43 loaded with a live load of 40 PSF and spaced 16 inches OC?

13′-5″




What is the recommended spacing at all panel edge and end joints when
positioning plywood subfloor?

1/8"




Which of the following is NOT a purpose of wall sheathing?

Información del documento

Subido en
15 de abril de 2025
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Nursehellen
4.3
(19)
Vendido
89
Seguidores
32
Artículos
1405
Última venta
16 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes