Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. -Correct Answer B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 Every absorption refrigerating system supported from the ground shall rest on a concrete slab extending not less than _____ the adjoining ground level.(A) 3 inches below(B) 3 inches above (C) 6 inches below(D) 6 inches above. -Correct Answer B. Slab extending not less than 3" above the adjoining ground level. UMC Section 1106.2 Any part of a venting system installed at an angle greater than 45 degrees from the vertical is considered by code to be _____.(A) vertica(B) horizontal l (C) a flat vent (D) an offset vent -Correct Answer B. any part of the venting installed at an angle GREATER than 45 degrees is considered by this code to be Horizontal UMC Section 802.6.1.1 Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4 C.5 D.6. -Correct Answer D. Dryers shall not exceed 6 feet in length. UMC Section 504.3.2.1 Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l (C) fiberglass (D) A and C apply -Correct Answer A. Shall Be Constructed of sheet metal. UMC Section. 5 0 6.1 Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride C) fiberglass (D) A and C apply -Correct Answer A 511.2 Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less than _____ inches. Is the Answer: A. 10" B. 12" C 16" D. 18". -Correct Answer D. clearance of an unlisted vented gas fireplace at the sides and the rear not less than 18". UMC Section 908.2(B) Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame (C) with a noncorrosive leak-detecting fluid (D) by increasing the air pressure during a test until the leaks are heard as a whistle. -Correct Answer C. leaks in a gas piping shall be located with a non corrosive leak detecting fluid. UMC Section 1316.4.2 Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8" B.¼" C.½" D. 1" -Correct Answer A. Slope of not less than 1/8" per foot. UMC Section 309.1 The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches or less in size is _____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG -Correct Answer C. 18 Minimum Gauge note: AWG is the abbreviation for "gauge size" Table 6-7(B) When smoke detectors are required as part of an automatic shutoff system, they shall be installed in the _____. A. return air duct ahead of any fresh-air inlet(B) main supply air duct served by such equipment(C) fresh-air inlet(D) main return and the main supply duct. -Correct Answer B. shall be installed in the main supply air duct served by equipment. UMC Section 609.0(5) The largest fuel-burning appliance allowed in a room 100'W x 20'L x 8'H without combustion air openingsis _____ Btu.(A) 80,000 (C) 140,000(B) 100,000 (D) 320,000 -Correct Answer 31 D. 701.2.1

Vista previa del contenido

HVAC JOURNEYMAN



HVAC JOURNEYMAN Exam Questions and Correct
Detailed Answers Top Rated 2025
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and
retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much
less than the air test. -Correct Answer ✔B. Fitting shall be replaced or repaired and
retested. UMC Section 1316.4.3


Every absorption refrigerating system supported from the ground shall rest on a
concrete slab extending not less than _____ the adjoining ground level.(A) 3 inches
below(B) 3 inches above (C) 6 inches below(D) 6 inches above. -Correct Answer ✔B. Slab
extending not less than 3" above the adjoining ground level. UMC Section 1106.2


Any part of a venting system installed at an angle greater than 45 degrees from the
vertical is considered by code to be _____.(A) vertica(B) horizontal l (C) a flat vent (D) an
offset vent -Correct Answer ✔B. any part of the venting installed at an angle GREATER
than 45 degrees is considered by this code to be Horizontal UMC Section 802.6.1.1


Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4
C.5 D.6. -Correct Answer ✔D. Dryers shall not exceed 6 feet in length. UMC Section
504.3.2.1


Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or
solid materials shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l (C)
fiberglass (D) A and C apply -Correct Answer ✔A. Shall Be Constructed of sheet metal.
UMC Section. 5 0 6.1


Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or
solid materials shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride C)
fiberglass (D) A and C apply -Correct Answer ✔A 511.2



HVAC JOURNEYMAN

, HVAC JOURNEYMAN




Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less
than _____ inches. Is the Answer: A. 10" B. 12" C 16" D. 18". -Correct Answer ✔D.
clearance of an unlisted vented gas fireplace at the sides and the rear not less than 18".
UMC Section 908.2(B)


Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame (C)
with a noncorrosive leak-detecting fluid (D) by increasing the air pressure during a test
until the leaks are heard as a whistle. -Correct Answer ✔C. leaks in a gas piping shall be
located with a non corrosive leak detecting fluid. UMC Section 1316.4.2


Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8"
B.¼" C.½" D. 1" -Correct Answer ✔A. Slope of not less than 1/8" per foot. UMC Section
309.1


The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches
or less in size is _____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG -Correct Answer ✔C.
18 Minimum Gauge note: AWG is the abbreviation for "gauge size" Table 6-7(B)


When smoke detectors are required as part of an automatic shutoff system, they shall be
installed in the _____. A. return air duct ahead of any fresh-air inlet(B) main supply air
duct served by such equipment(C) fresh-air inlet(D) main return and the main supply
duct. -Correct Answer ✔B. shall be installed in the main supply air duct served by
equipment. UMC Section 609.0(5)


The largest fuel-burning appliance allowed in a room 100'W x 20'L x 8'H without
combustion air openingsis _____ Btu.(A) 80,000 (C) 140,000(B) 100,000 (D) 320,000 -
Correct Answer ✔31 D. 701.2.1




HVAC JOURNEYMAN

Información del documento

Subido en
15 de abril de 2025
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$17.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PossibleA
3.9
(152)
Vendido
1076
Seguidores
651
Artículos
14028
Última venta
19 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes