HVAC JOURNEYMAN EXAM
QUESTIONS AND CORRECT
DETAILED ANSWERS TOP RATED
VERSION FOR ALREADY A+ GRADED
WITH EXPERT FEEDBACK|BRAND
NEW!|REVISED
Save
Practice questions for this set
Learn
Studied 7 terms
Nice work, you're crushing it
Continue studying in Learn
,Terms in this set (127)
Defects on gas B. Fitting shall be replaced or repaired
piping or fittings and retested. UMC Section 1316.4.3
shall be _____.(A)
repaired(B)
replaced or
repaired and
retested(C)
repaired by a
certified welder(D)
ignored, as the
operating pressure
is much less than
the air test.
,Every absorption B. Slab extending not less than 3" above
refrigerating the adjoining ground level. UMC
system supported Section 1106.2
from the ground
shall rest on a
concrete slab
extending not less
than _____ the
adjoining ground
level.(A) 3 inches
below(B) 3 inches
above (C) 6 inches
below(D) 6 inches
above.
Any part of a B. any part of the venting installed at an
venting system angle GREATER than 45 degrees is
installed at an considered by this code to be
angle greater than Horizontal UMC Section 802.6.1.1
45 degrees from
the vertical is
considered by
code to be _____.(A)
vertica(B)
horizontal l (C) a
flat vent (D) an
offset vent
, Listed transition D. Dryers shall not exceed 6 feet in
ducts f or clothes length. UMC Section 504.3.2.1
dryers shall not
exceed_____ feet in
length. A.3 B.4 C.5
D.6.
Industrial product- A. Shall Be Constructed of sheet metal.
conveying ducts UMC Section. 5 0 6.1
and their fittings
for abrasive and
nonabrasive dust
or solid materials
shall be
constructed of
_____.(A) sheet
meta(B) polyvinyl
chloride l (C)
fiberglass (D) A
and C apply
QUESTIONS AND CORRECT
DETAILED ANSWERS TOP RATED
VERSION FOR ALREADY A+ GRADED
WITH EXPERT FEEDBACK|BRAND
NEW!|REVISED
Save
Practice questions for this set
Learn
Studied 7 terms
Nice work, you're crushing it
Continue studying in Learn
,Terms in this set (127)
Defects on gas B. Fitting shall be replaced or repaired
piping or fittings and retested. UMC Section 1316.4.3
shall be _____.(A)
repaired(B)
replaced or
repaired and
retested(C)
repaired by a
certified welder(D)
ignored, as the
operating pressure
is much less than
the air test.
,Every absorption B. Slab extending not less than 3" above
refrigerating the adjoining ground level. UMC
system supported Section 1106.2
from the ground
shall rest on a
concrete slab
extending not less
than _____ the
adjoining ground
level.(A) 3 inches
below(B) 3 inches
above (C) 6 inches
below(D) 6 inches
above.
Any part of a B. any part of the venting installed at an
venting system angle GREATER than 45 degrees is
installed at an considered by this code to be
angle greater than Horizontal UMC Section 802.6.1.1
45 degrees from
the vertical is
considered by
code to be _____.(A)
vertica(B)
horizontal l (C) a
flat vent (D) an
offset vent
, Listed transition D. Dryers shall not exceed 6 feet in
ducts f or clothes length. UMC Section 504.3.2.1
dryers shall not
exceed_____ feet in
length. A.3 B.4 C.5
D.6.
Industrial product- A. Shall Be Constructed of sheet metal.
conveying ducts UMC Section. 5 0 6.1
and their fittings
for abrasive and
nonabrasive dust
or solid materials
shall be
constructed of
_____.(A) sheet
meta(B) polyvinyl
chloride l (C)
fiberglass (D) A
and C apply