"Prepare for the EPA 603 Certification Exam with this detailed study guide tailored for HVAC technicians and professionals involved in refrigerant management. This guide provides an in-depth exploration of the regulations and practices related to the safe handling of refrigerants, including recovery, recycling, and proper disposal methods. You'll find clear explanations of key concepts, practical examples, and practice questions designed to reinforce your understanding and boost your confidence before the exam. With this study guide, you’ll be well-equipped to achieve certification and ensure compliance with environmental standards."

Vista previa del contenido

EPA_608_Certification_Study_Guide_
2025-2026
1. November 14, 1994 What date was the sale of
CFC's & HCFC's restricted
to technicians certi�ed in
refrigerant recovery?

2. Memorize it, ya'll. 1989-
Montreal Protocol

July 1 1992-
Violation to vent CFCs or
HCFCs

Nov 15 1993-
Recovery/Recycling
equipment must be
certi�ed and labeled by
EPA
AND
Before this date recovery
equipment needed to be
capable of removing 80%
of the refrigerant, w or wo
compressor, or 4 in Hg
After this date recovery
equipment needs to be
capable of removing 90%,
or 80% without working
compressor, or 4 in Hg
AND
Required level of evacua-
tion for Low Pressure ap-
pliances before this date



, was 25 inches Hg, after
this date 25 mm Hg

Nov 14 1994-
Certi�cation needed to
service, maintain, or dis-
pose of appliances with
refrigerants AND
Sale of CFC and HCFC
refrigerants restricted to
certi�ed techs

Nov 15 1995-
Violation to vent HFCs

Dec 31 1995-
CFCs no longer produced

3. 15% Comfort cooling appli-
ances containing more
than 50 lbs of refrigerant
must be repaired when
the annual leak rate ex-
ceeds _____%

4. 35% Commercial and Industrial
process refrigeration con-
taining ore than 50 lbs
of refrigerant must be re-
paired when the annual
leak rate exceeds _____%

5.


, 00 Required Recovery Levels
4 10 for Type II appliances, be-
4 10 fore and after 11/15/93:
4 15
00 HCFC22 less than 200 lbs
= B4-0 After-0
HCFC22 more than 200
lbs= B4-4 After-10
NonHCFC22 less than 200
lbs= B4-4 After 10
NonHCFC22 more than
200 lbs= B4 4 After 15
Very high pressure appli-
ances= B4-0 After-0

6. Recover all refrigerants. Section 608 of the Feder-
al Clean Air Act requires
technicians to what?

7. The earth's stratosphere. The objective of the Clean
Air Act is to protect what?

8. HydroFlouroCarbon's HFC's

9. ChloroFluoroCarbon's CFC's

10. Ozone Depletion Potential ODP

11. The Montreal Protocol. Which international treaty
agreement was the basis
for Section 608?

12. 1.Crop losses
2.Increases in eye diseases


, 3.Skin Cancer Depletion of the ozone in
4.Reduced marine life the stratosphere is known
5.Deforestation to cause what 6 things?
6.Increased ground level ozone

13. These atoms attack Ozone Molecules causing the for- What happens when CFC
mation of Chlorine Monoxide (CLO), after colliding or HCFC molecules get in
with another Ozone Molecule, causes 2 Oxygen (O2) the stratosphere & free
molecules to be made & leaving an atom of chlorine atoms of Chlorine are set
to act as "Free Agent" starting the process over until free?
100,000 molecules of Ozone are destroyed by just one
atom of chloride.

14. November 15, 1993 What date was recovery
equipment required to be
certi�ed by a lab, & achieve
higher evacuation levels, &
have low loss �ttings?

15. November 14, 1994 On what date was techni-
cian certi�cation required?

16. December 31, 1995 What date were CFC's
phased out of production?

17. Persons who maintain, service, repair, or dispose of What is EPA 608 Type I
small appliances (containing 5 pounds of refrigerant certi�cation?
(or less).

18. Persons who maintain, service, repair, or dispose of What is EPA 608 Type II
high and very high pressure appliances. Except small certi�cation?
appliances and motor vehicle air conditioning sys-
tems.

Información del documento

Subido en
28 de marzo de 2025
Número de páginas
40
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$21.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Vendido
107
Seguidores
2
Artículos
5428
Última venta
6 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes