• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 5 páginas
Examen

Rad Safety || A+ Guaranteed.

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

Which of the following results from restriction of the x-ray beam? correct answers Less scattered radiation production, less patient dose Which of the following is likely to improve image quality and decrease patient dose? correct answers beam restriction The reduction in the intensity of an x-ray beam as it passes through material is termed: correct answers attenuation Protective devices such as lead aprons function to protect the technologist from: correct answers Scattered radiation An increase in total filtration of the x-ray beam will increase: correct answers Beam HVL The largest dose to the male gonads is most likely to result from which of the following exposures? correct answers XTL Hip All of the following affect patient dose except: correct answers focal spot size Which of the following is (are) important for patient protection during fluoro procedures? correct answers Intermittent fluoro, fluoro field size, focus-to-table distance Aluminum filtration has its greatest effect on: correct answers long wavelength radiation Patient dose increases as fluoroscopic: correct answers FOC decreases It is necessary to question a female pt of childbearing age regarding the: correct answers Date of her last menstrual period, possibility of her being pregnant How does filtration affect the primary beam? correct answers it increases the avg energy of the primary beam Which of the following most effectively minimizes radiation exposure to the patient? correct answers High-speed imaging system The use of which of the following devices helps reduce the patient dose? correct answers Collimator and gonad shield The focal spot-to-table distance, in mobile fluoroscopy, must be: correct answers a minimum of 12 inches Any wall that the useful x-ray beam can be directed toward is called a: correct answers primary barrier

Vista previa del contenido

Rad Safety || A+ Guaranteed.
Which of the following results from restriction of the x-ray beam? correct answers Less scattered
radiation production, less patient dose

Which of the following is likely to improve image quality and decrease patient dose? correct
answers beam restriction

The reduction in the intensity of an x-ray beam as it passes through material is termed: correct
answers attenuation

Protective devices such as lead aprons function to protect the technologist from: correct answers
Scattered radiation

An increase in total filtration of the x-ray beam will increase: correct answers Beam HVL

The largest dose to the male gonads is most likely to result from which of the following
exposures? correct answers XTL Hip

All of the following affect patient dose except: correct answers focal spot size

Which of the following is (are) important for patient protection during fluoro procedures? correct
answers Intermittent fluoro, fluoro field size, focus-to-table distance

Aluminum filtration has its greatest effect on: correct answers long wavelength radiation

Patient dose increases as fluoroscopic: correct answers FOC decreases

It is necessary to question a female pt of childbearing age regarding the: correct answers Date of
her last menstrual period, possibility of her being pregnant

How does filtration affect the primary beam? correct answers it increases the avg energy of the
primary beam

Which of the following most effectively minimizes radiation exposure to the patient? correct
answers High-speed imaging system

The use of which of the following devices helps reduce the patient dose? correct answers
Collimator and gonad shield

The focal spot-to-table distance, in mobile fluoroscopy, must be: correct answers a minimum of
12 inches

Any wall that the useful x-ray beam can be directed toward is called a: correct answers primary
barrier

, The amount of time that x-rays are being produced and directed toward a particular wall is
referred to as the: correct answers use factor

To be in compliance with radiation safety standards, the fluoro exposure switch must: correct
answers be of the dead man type

Under what circumstances might a radiographer be required to wear two dosimeters: correct
answers During pregnancy, performing vascular procedures

Which of the following are recommended for the pregnant radiographer? correct answers
Continue monthly dosimeter readings, wear a second dosimeter under the lead apron

A controlled area is defined as one: correct answers that is occupied by people trained in
radiation safety, that is occupied by people who wear radiation monitors, whose occupancy
factor is 1

What is the single most important scattering object in both radiography and fluoroscopy? correct
answers patient

According to the NCRP, the annual occupational whole-body dose equivalent limit for students
under the age of 18 is: correct answers 1 mSv

How will x-ray photon intensity be affected if the SID is doubled? correct answers It's intensity
will decrease 4 times.

Primary radiation barriers must be at least how high? correct answers 7 feet

Occupational radiation monitoring is required when it is likely that an individual will receive
more than what fraction of the annual dose limit? correct answers 1/10

radiation that possesses the ability to remove electrons from atoms by process called ionization
correct answers ionizing radiation

effects of radiation on the body being irradiated correct answers somatic effects

effects of radiation on the genetic code of a cell; affects the next generation correct answers
genetic effect

radiation contained in the unpolluted environment correct answers natural background radiation

also called man-made radiation (medical x-rays) correct answers artificially produced x-rays

radiation exiting the x-ray tube correct answers primary radiation

x-rays that emerge from the patient and strike the IR correct answers exit radiation (remnant
radiation)

Información del documento

Subido en
25 de marzo de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SirAnton
3.7
(118)
Vendido
810
Seguidores
438
Artículos
40067
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes