Fresenius Final Exam

,40-60 seconds - CORRECT ANSWERS-How long to hand wash with soap and water?

20-30 seconds - CORRECT ANSWERS-How long must you rub your hands with hand
sanitizer?

Diabetes - CORRECT ANSWERS-The number one cause for chronic renal failure

True - CORRECT ANSWERS-When going from a dirty area to retrieve supplies in a
clean area, staff are required to complete hand hygiene

True - CORRECT ANSWERS-HMIS (Hazardous Material Identification System) labels
are required on all hazardous materials, including individual bicarbonate containers

1 part bleach: 10 part water solution - CORRECT ANSWERS-The first bleach solution
used to clean a large blood spill area (greater than 10mL/s) is

Infected blood and bodily fluids - CORRECT ANSWERS-The main route of transmission
of Hep B in Hemodialysis facilities is by exposure to

Remove gloves, sanitize hands, and put on a fresh pair of gloves before - CORRECT
ANSWERS-When caring for a patient who is Hep B positive, after disconnecting the
bloodlines, the technician must perform which 3 actions before documenting?

Separate area on a dedicated machine - CORRECT ANSWERS-Patients who are Hep
B surgace Antigen positive should be dialyzed in a

Remove gloves, wash/sanitize hands, and retrieve items - CORRECT ANSWERS-What
must a tech do prior to leaving the patient at the dialysis station to get clean supplies?

Remove gloves, wash/sanitize hands - CORRECT ANSWERS-The tech has performed
rinseback on a patient and failed to gather all the supplies needed to disconnect the
patient. What must the tech do prior to getting supplies?

Blood splatter - CORRECT ANSWERS-You must wear a full-face shield, or mask with
goggles when in an area with a risk of

Ultrapure Dialysate - CORRECT ANSWERS-Use of a diasafe filter allows the
production of

Conductivity - CORRECT ANSWERS-the ability of a substance to conduct an electrical
charge

Normal Saline - CORRECT ANSWERS-Used to rinse and prime the tubing of the
extracorporeal circuit to remove sterilant and air

, Clotting - CORRECT ANSWERS-Air is removed from the extracorporeal circuit before
initiating treatment because it may cause

bloodlines in the prime bucket with open end caps - CORRECT ANSWERS-The most
likely cause of contamination of the extracorporeal circuit are

Air - CORRECT ANSWERS-A low level arterial drip chamber can result in ______
entering the system causing an air embolism or clotting

Conductivity - CORRECT ANSWERS-Ability of a substance to conduct an electrical
charge

Blood leak - CORRECT ANSWERS-When blood escapes from the dialyzer blood
compartment into the dialysate fluid compartment

6.9-7.6 - CORRECT ANSWERS-The final dialysate must have a ph between

Daily - CORRECT ANSWERS-How often should staff clean the dialysis machine with
acid?

Before each treatment - CORRECT ANSWERS-When should alarm and Pressure
Holding Tests (PHT) should be performed on dialysis machines?

Air in the dialyzer - CORRECT ANSWERS-What is removed by NS during the priming
process?

+/-0.5mS of Theoretical Conductivity - CORRECT ANSWERS-Before the start of
treatment, check that the machine's conductivity alarm parameters are set at

after cleaning with acid - CORRECT ANSWERS-You should disinfect the dialysis
machine with heat after doing what?

Bacteria, Conductivity, Chlorine/Chloramines and pH - CORRECT ANSWERS-You
should test the dialysate for these four things before starting treatment

The machine was in bypass for 30 min - CORRECT ANSWERS-The wall clock
indicates the patient has had 3 hours of treatment and the machine indicates only 2.5
hours treatment. What happened?

Kidneys to Ureters to Bladder to Urethra - CORRECT ANSWERS-Flow of urine

Pressure difference across the dialyzer membrane - CORRECT ANSWERS-The TMP
(Transmembrane Pressure) measures the

Diffusion - CORRECT ANSWERS-Movement of particles from a greater to a lesser
concentration
$18.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Sellexamonline

Conoce al vendedor

Seller avatar
Sellexamonline Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
6
Miembro desde
2 año
Número de seguidores
5
Documentos
136
Última venta
1 año hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes