NATE GAS HEAT STUDY GUIDE TEST. 3/8 to ½ inch of the end of the thermocouple - CORRECT ANSWER Should be enveloped by the pilot flame A control string is defined as two or more switch contacts connected in a circuit, or set of circuits, to control a load. In order to troubleshoot a load controlled by a control string, the technician must first: - CORRECT ANSWER Check for proper voltage applied across the load. A customer complains the unit is "blowing cold air". The technician determines that the problem occurs at the end of the heating sequence. The furnace used an electronic integrated blower control. - CORRECT ANSWER The likely problem with the system is the blower off delay is set too long. A customer has concerns about carbon monoxide (CO) in their hone. Many of their reported symptoms indicate there may indeed be a CO problem but on each trip the technician makes to check their home the technician finds normal CO levels. - CORRECT ANSWER CO detector reader/recorder would be appropriate to use for determining if a problem truly exists. A damaged section of double wall vent pipe is to be replaced with a section produced by a different manufacturer: - CORRECT ANSWER The installer should check the new section for compatible locking joints. A dirty or clogged air filter in an operating gas furnace can cause an: - CORRECT ANSWER Increase temperature rise. A furnace is inoperative because of a failure in the ignition sequence at the flame proving stage. To check the flame proving circuit the technician would: - CORRECT ANSWER Connect a microampmeter set to DC microamps in the sensor circuit and operate the furnace. A gas clothes dryer can interfere with the operation of a nearby natural draft gas furnace with an atmospheric burner by: - CORRECT ANSWER Stealing combustion air preventing complete fuel burning. A gas furnace should reach a steady state - CORRECT ANSWER Before taking a combustion test A gas furnace with a standing pilot uses a flame switch for proving pilot flame. - CORRECT ANSWER Several millivolts are generated by the flame. A line voltage fuse is sized to protect from: - CORRECT ANSWER Excessive voltage A meter reading microfarads is used to: - CORRECT ANSWER Check a run capacitor with a capacitance tester. A packaged unit in a two story installation is to be located at ground level with ductwork running up the outside wall to a chase in the second floor. - CORRECT ANSWER The precautions need to be taken with outside ductwork is it must be insulated and weatherproofed. A standing pilot furnace uses a relay for controlling the supply blower. On a call for heat, the burner lights, the fan control closes, but the blower does not run. A check of voltage at the blower relay coil shows 24V. The load side measures 0V. The technician should replace what: - CORRECT ANSWER Fan relay. A system airflow check determines that supply static is 0.15 in. W.C. and return static is a negative 0.55 in. W.C. these readings tell the technician: - CORRECT ANSWER The difference between supply static and return static is unacceptably low. A system that is oversized for the load: - CORRECT ANSWER Will cause the unit to short cycle. A technician is installing a gas furnace and the customer has decided not to install an air conditioner. Making this decision, the affect it will have on the installation of the supply ductwork is: - CORRECT ANSWER Leave adequate space should be allowed for addition of a coil in the future when feasible. A technician measures the return air temperature of a 100,000 BTU output gas furnace to be 65°F and the supply side air temperature is 135°F: - CORRECT ANSWER The CFM would be 1323.

Vista previa del contenido

NATE GAS HEAT STUDY GUIDE TEST.

3/8 to ½ inch of the end of the thermocouple - CORRECT ANSWER Should be enveloped by the pilot
flame



A control string is defined as two or more switch contacts connected in a circuit, or set of circuits, to
control a load. In order to troubleshoot a load controlled by a control string, the technician must first: -
CORRECT ANSWER Check for proper voltage applied across the load.



A customer complains the unit is "blowing cold air". The technician determines that the problem occurs
at the end of the heating sequence. The furnace used an electronic integrated blower control. -
CORRECT ANSWER The likely problem with the system is the blower off delay is set too long.



A customer has concerns about carbon monoxide (CO) in their hone. Many of their reported symptoms
indicate there may indeed be a CO problem but on each trip the technician makes to check their home
the technician finds normal CO levels. - CORRECT ANSWER CO detector reader/recorder would be
appropriate to use for determining if a problem truly exists.



A damaged section of double wall vent pipe is to be replaced with a section produced by a different
manufacturer: - CORRECT ANSWER The installer should check the new section for compatible locking
joints.



A dirty or clogged air filter in an operating gas furnace can cause an: - CORRECT ANSWER Increase
temperature rise.



A furnace is inoperative because of a failure in the ignition sequence at the flame proving stage. To
check the flame proving circuit the technician would: - CORRECT ANSWER Connect a microampmeter
set to DC microamps in the sensor circuit and operate the furnace.



A gas clothes dryer can interfere with the operation of a nearby natural draft gas furnace with an
atmospheric burner by: - CORRECT ANSWER Stealing combustion air preventing complete fuel burning.

, A gas furnace should reach a steady state - CORRECT ANSWER Before taking a combustion test



A gas furnace with a standing pilot uses a flame switch for proving pilot flame. - CORRECT ANSWER
Several millivolts are generated by the flame.



A line voltage fuse is sized to protect from: - CORRECT ANSWER Excessive voltage



A meter reading microfarads is used to: - CORRECT ANSWER Check a run capacitor with a capacitance
tester.



A packaged unit in a two story installation is to be located at ground level with ductwork running up the
outside wall to a chase in the second floor. - CORRECT ANSWER The precautions need to be taken with
outside ductwork is it must be insulated and weatherproofed.



A standing pilot furnace uses a relay for controlling the supply blower. On a call for heat, the burner
lights, the fan control closes, but the blower does not run. A check of voltage at the blower relay coil
shows 24V. The load side measures 0V. The technician should replace what: - CORRECT ANSWER Fan
relay.



A system airflow check determines that supply static is 0.15 in. W.C. and return static is a negative 0.55
in. W.C. these readings tell the technician: - CORRECT ANSWER The difference between supply static
and return static is unacceptably low.



A system that is oversized for the load: - CORRECT ANSWER Will cause the unit to short cycle.



A technician is installing a gas furnace and the customer has decided not to install an air conditioner.
Making this decision, the affect it will have on the installation of the supply ductwork is: - CORRECT
ANSWER Leave adequate space should be allowed for addition of a coil in the future when feasible.



A technician measures the return air temperature of a 100,000 BTU output gas furnace to be 65°F and
the supply side air temperature is 135°F: - CORRECT ANSWER The CFM would be 1323.

Información del documento

Subido en
16 de marzo de 2025
Número de páginas
13
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ROSEGRADES
3.4
(35)
Vendido
236
Seguidores
87
Artículos
12121
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes