ICC Complete Study Guide Test. Energized parts operating at a minimum of ________ shall be guarded against accidental contact by people through the use of approved enclosures. - CORRECT ANSWER 60 volts Work space in from to f an electrical panel board shall be a minimum of _____ inches in width, but no less than the width of the panel board. - CORRECT ANSWER 30 inches Where electrical conductors are to be spliced, terminated or connected to fixtures or devices, a minimum length of _____ inches of free conductor shall be provided at each outlet, junction or switch point. 1/1 - CORRECT ANSWER 6 inches Where it is impractical to locate the service head or goose neck above the point of attachment of the service-drop or overhead service conductors to the building, the service head or goose neck shall be located a maximum of _____ inches from the point of attachment. 1/1 12 - CORRECT ANSWER 24 An open service conductor without an overall outer jacket shall have a minimum clearance of ____ from the sides of doors, porches and operable windows. - CORRECT ANSWER 3 feet In all cases, the point of attachment of service-drop conductors to a building shall be a minimum of ____ above finished grade. - CORRECT ANSWER 12 feet A metal underground water pipe used as part of the grounding electrode system shall be in direct contact with the earth for a minimum of _____. - CORRECT ANSWER 10 feet Where used outside, an aluminum or coper-clad aluminum grounding electrode conductor shall be installed a minimum of _____ from the earth. - CORRECT ANSWER 18 Inches A minimum of _____ branch circuit(s) shall be provided for receptacles located in the laundry room and a minimum of _____ branch circuit(s) shall be provided to supply the bathroom receptacle outlet(s). - CORRECT ANSWER one 20 ampere rated, one 20 ampere rated In the calculation of electrical feeder loads, an electric clothes dryer load shall be considered _____ VA for each dryer circuit or the nameplate load of each dryer, whichever is greater. - CORRECT ANSWER 5000 What is the maximum over current-protection-device rating permitted for No. 12 copper conductors? - CORRECT ANSWER 20 amps Electrical panel boards and over current protection devices shall not be located in:___________ - CORRECT ANSWER Clothes closets Where metallic plugs or plates are used with nonmetallic electrical enclosures to close unused openings, they shall be recessed a minimum of _______ inches from the outer surface of the enclosure. - CORRECT ANSWER 1/4 Electrical service disconnecting means shall not be installed in __________. - CORRECT ANSWER Bathroom

Vista previa del contenido

ICC Complete Study Guide Test.

Energized parts operating at a minimum of ________ shall be guarded against accidental contact by
people through the use of approved enclosures. - CORRECT ANSWER 60 volts



Work space in from to f an electrical panel board shall be a minimum of _____ inches in width, but no
less than the width of the panel board. - CORRECT ANSWER 30 inches



Where electrical conductors are to be spliced, terminated or connected to fixtures or devices, a
minimum length of _____ inches of free conductor shall be provided at each outlet, junction or switch
point.

1/1 - CORRECT ANSWER 6 inches



Where it is impractical to locate the service head or goose neck above the point of attachment of the
service-drop or overhead service conductors to the building, the service head or goose neck shall be
located a maximum of _____ inches from the point of attachment.

1/1

12 - CORRECT ANSWER 24



An open service conductor without an overall outer jacket shall have a minimum clearance of ____ from
the sides of doors, porches and operable windows. - CORRECT ANSWER 3 feet



In all cases, the point of attachment of service-drop conductors to a building shall be a minimum of ____
above finished grade. - CORRECT ANSWER 12 feet



A metal underground water pipe used as part of the grounding electrode system shall be in direct
contact with the earth for a minimum of _____. - CORRECT ANSWER 10 feet



Where used outside, an aluminum or coper-clad aluminum grounding electrode conductor shall be
installed a minimum of _____ from the earth. - CORRECT ANSWER 18 Inches

Información del documento

Subido en
4 de febrero de 2025
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ROSEGRADES
3.4
(35)
Vendido
236
Seguidores
87
Artículos
12121
Última venta
3 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes