Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 27 páginas
Examen

Fiber Installation and Activation LATEST UPDATED Exam Questions and Answers 100% Pass SURE PASS!! GRADED AT A+

Document preview thumbnail
Vista previa 3 fuera de 27 páginas

Fiber Installation and Activation LATEST UPDATED Exam Questions and Answers 100% Pass SURE PASS!! GRADED AT A+ 1.A fiber optic inspector microscope can increase the danger of high powerd light source by focusing the light out of a fiber into your eyes. - ANSWER True 2.Cable Ties used on fiber optic cables - ANSWER Can harm cables it too tight so they should be hand_tightened 3. Fiber optic joints connectors or slices should have_________. - ANSWER Hight mechanical strength and low loss 4. To reduce _________ as well as loss the end of a connector is polished to a PC physical contact finish. - ANSWER Reflectance 5. Factory termination such as used for making patch cords generally use what method of attaching the connector to the cable. - ANSWER Epoxy/polish 6. What connector style is now specified in the TIA premises cabling standard TIA-568B.3? - ANSWER Any connector standardize by FOCIS document. 7. According to the text the connector in the following list with the BEST lower REFLECTANCE is the - ANSWER SC-APC 8. _______ termination type connectors do not need to be polished. - ANSWER Cleave and crimp prepolished/splice 9. A fiber optic power meter measures absolute power in dBm (dB reference to 1 mw) and when a light source measures insertions loss in dB. - ANSWER True 11. Confining light in a material by surrounding it by another material with lower refractive index is the phenomenon of - ANSWER Total internal reflection 12. The largest cause of attenuation in am optical fiber is - ANSWER Scattering 13.When we say 62.5/125 fiber what does "62.5" means? - ANSWER Core size, diameter in microns 14. When we say 50/125 fiber what does "125" mean? - ANSWER Cladding size the diameter in microns 15. An older multimode fiber design with a 50/125 micron

Vista previa del contenido

Fiber Installation and Activation LATEST
UPDATED Exam Questions and Answers
100% Pass SURE PASS!!
GRADED AT A+

1.A fiber optic inspector microscope can increase the danger of high powerd light
source by focusing the light out of a fiber into your eyes. - ANSWER True

2.Cable Ties used on fiber optic cables - ANSWER Can harm cables it too tight so
they should be hand_tightened

3. Fiber optic joints connectors or slices should have_________. - ANSWER Hight
mechanical strength and low loss

4. To reduce _________ as well as loss the end of a connector is polished to a PC
physical contact finish. - ANSWER Reflectance

5. Factory termination such as used for making patch cords generally use what
method of attaching the connector to the cable. - ANSWER Epoxy/polish

6. What connector style is now specified in the TIA premises cabling standard
TIA-568B.3? - ANSWER Any connector standardize by FOCIS document.

7. According to the text the connector in the following list with the BEST lower
REFLECTANCE is the - ANSWER SC-APC

8. _______ termination type connectors do not need to be polished. - ANSWER
Cleave and crimp prepolished/splice


9. A fiber optic power meter measures absolute power in dBm (dB reference to 1
mw) and when a light source measures insertions loss in dB. - ANSWER True

11. Confining light in a material by surrounding it by another material with lower
refractive index is the phenomenon of - ANSWER Total internal reflection

,12. The largest cause of attenuation in am optical fiber is - ANSWER Scattering

13.When we say 62.5/125 fiber what does "62.5" means? - ANSWER Core size,
diameter in microns

14. When we say 50/125 fiber what does "125" mean? - ANSWER Cladding size
the diameter in microns

15. An older multimode fiber design with a 50/125 micron core is now option in
premises cabling system because it - ANSWER Has a higher bandwidth which
gives more distance capability with gigabit network

16. In multimode fiber the attenuation of the fiber is __________ at 850 nm that's
1300 nm - ANSWER Higher

17. Which of the following represent a singlemode fiber size ? - ANSWER 9/125

18. Singlemode fiber has ______ bandwidth in both multimode and singlemode
fiber - ANSWER Greater

19. What form of dispersion affect bandwidth in both multimode and singlemode
fiber - ANSWER Chromatic dispersion

20. Most plastic optical fiber are - ANSWER Large core step-index

21. When you strip singlemode or graded index multimode mode glass fiber you
are removing the - ANSWER Primary buffer coating

22. The outermost layer of protection for an optic fiber cable is - ANSWER The
jacket

23. The proper method of pulling optical fiber is to attach the pull wire or tape to
the - ANSWER Strength members

24. According to the text HYBRIDcables refer to cable that contain - ANSWER
Both singlemode and multimode optical fibers

25. What type of fiber cable design allows for large number of fibers with ultra
high density low cost small size diameters? - ANSWER Ribbon

, 26. When flexibility and ease of termination are priory the type of cable best suited
is - ANSWER Tight buffer

27. What standard covers flammability requirements of fiber optic cables for
installation in premises application - ANSWER NEC 770.50

28.According to the text Composite cable refer to cable that contain - ANSWER
Both optical fiber and copper must be grounded

29. Which optical fiber cable must be grounded - ANSWER All optical cable that
contain metal

30. Which NEC rated cable can be used in air handling space of building -
ANSWER OFNP(US)

31. Optical fiber cable with a orange colored jacket generally indicates the cable
contain - ANSWER Multimode fiber

32. Premises cable jacket are usually color-code in what color to indicate
singlemode fiber? - ANSWER yellow

33. The minimum bend radius for cable while pulling under tension during
installation is - ANSWER 20 times the cable diameter

34. When pulling long length of cable in conduit or inner duct you may need to -
ANSWER Any or all of these as appropriate
Use a breakaway swivel or monitor tension
Lubrica the cable
Pull from the center to the end.

35. In a loose tube buffer cable gel or absorbent tape is normally uesd - ANSWER
To prevent water from entering the cable

36. What type of cable may require installation of breakout kit also called a
function or fan out kit for termination - ANSWER Loose tube (loose buffer) cable


37. Splices are most often used for - ANSWER A permanent joint between two
fiber

Información del documento

Subido en
24 de enero de 2025
Número de páginas
27
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Exchequer
3.2
(11)
Vendido
78
Seguidores
1
Artículos
1445
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes