HVAC contractor exam test 6
Zero on the Rankin scale (0 degrees R) is equivalent to what temperature
Fahrenheit? - --460 degrees F

- Some old, large oil-filled capacitors (found in fluorescent lamp ballasts, and
other applications) can leak and create a safety hazard. This dielectric fluid
contains what type of material? - -PCBs (Polychlorinated biphenyl)

- A building with double pane windows has an outside termperature of 10
degrees F deg whie maintaining an inside temperature of 72 degrees F deg.
Calculate the MAXIMUM winter humidity design: - -30% RH

- What should be called a room where fuel-burning appliances are working
and its volume is NO MORE than 50 cubic feet per 1,000 Btu/h of input
rating? - -Confined space

- Capillary tube capacity is determined by the pressure difference, length of
the tube, and inside diameter of the tube. What size length tube would be
required given the following:
-High-temperature R-22 system
- 1/2 horsepower compressor - -108 inch length and .064 ID

- A worker has finished installing a gas piping system with 1,500 cubic feet
of pipe volume. AT LEAST for how long should he test the system? - -1 1/2
hours

- Dealing with Type 1 hoods and combustible construction: Select the
correct MINIMUM separation between the grease duct system and the
exhaust equipment. - -18 inches

- According to the Texas Air Conditioning and Refrigeration Administrative
Rules, which of the following can be performed by a non licensed person? - -
Install, repair, or remove a vent hood (remove mold from a duct)

- Referring to louvers and grilles and their size of openings for combustion,
ventilation and diluted air: Screens shall have a mesh size NOT SMALLER
THAN _________ inches. - -1/4 inch

- Which instrument is used to measure the pressure drop across an air filter?
- -Manometer

, - The installation of dryer exhaust, of commercial clothes dryers, shall have
ducts with a clearance of AT LEAST ______ inches to combustible materials. -
-6 inches

- The units of thermal conductivity are BTU/SQ.FT./HR. It is the measure of
__________? - -How quickly heat can travel through material

- When a HVAC technician works on a commercial unit, all of the following,
with the exception of which one, are likely causes of excessive noise? - -Low
head pressure

- Using the duct size calculator provided, what would be the approximate
Friction Loss (inches of water per 100 feet of duct) given the following
variables?
-12" x 8" rectangular duct
-1,000 CFM per 100 feet of duct - -.050

- TDLR has two license classifications that depended on what size air
conditioning and refrigeration units will be installed and serviced. What is the
limitation for a Class A contractor's license? - -None, heating and cooling of
any size

- Solve for the MINIMUM total area required in a 120,000 Btu furnace
supplied with combustion air from inside a building. - -120 square inches

- A technician is installing a 125,000 Btu/h fan-assisted gas-fired appliance
in a furnace room with a , Btu/h natural draft hot water heater. This unit has
two horizontal ducts communicating with the outdoors. Solve for the
MINIMUM size combustion air ducts required. - -10' x 10'

- In commercial systems, multiple temperature installations may short cycle
a pressure-controlled condenser. Therefore, to eliminate this problem, which
of the following could be installed in the main suction line just ahead of the
compressor? - -A surge tank

- Pressure relief devices, such as a refrigeration fusible plug, located within
the machinery room shall terminate outside of the structure at a location
NOT LESS THAN ________ feet? - -15 feet

- Which of the following refrigerant devices cannot be adjusted? - -Capillary
tube

- Ducts that operate at temperatures exceeding 120 degrees F shall have
sufficient thermal insulation to limit the exposed surface temperature to
________ degrees F. - -120 degrees F

Información del documento

Estudio
Subido en
19 de enero de 2025
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
4
Seguidores
0
Artículos
789
Última venta
6 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes