• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 1 fuera de 2 páginas
Examen

HVAC Contractor Test 1| Questions with Solutions

Document preview thumbnail
Vista previa 1 fuera de 2 páginas

HVAC Contractor Test 1| Questions with Solutions

Vista previa del contenido

HVAC Contractor Test 1|
Questions with Solutions
An air conditioning and refrigeration contracting company must notify the
department of all licensees who have assigned their licenses to the company
and must notify the department within how many calendar days when any
license whose license is assigned to the company has left the company - -30
calendar days

- within ___ hours after a death of any employee as a result of a work related
incident, you must report the fatality to the occupational safety and health
administration (OSHA), us Department of Labor. - -8 hours

- Where a closet is designed for the installation of a clothes dryer, an
opening having an area of not less than ___ for makeup air shall be provided
in the closet enclosure - -100 square inches

- Where communicating with the outdoors through horizontal ducts, each
opening shall have a minimum free area of 1in-sq/ ___ Btu/h of total input
rating of all appliances in the enclosure - -2000

- According to the standard method of calculation in the IFGC, what would
be the required volume in cubic feet of indoor combustion air be given a
100,000 But/hr gas furnace is rated with an annual fuel utilization efficiency
"AFUE" at 80% - -4,000

- The required size of openings for combustion, ventillation in dilution air
shall be based on the net free area of each opening where the design and
free area of louvers and grills are not known, it shall be assumed that wood
louvers will have ____ free area and metal louvers and grills will have _____
free area. - -Wood louvers will have a 25% free area opening and metal
louvers will have a 75% free area opening

- An oral or written agreement for construction alteration, or repair, of
buildings, structures, or systems is considered a ______? - -Contract

- Given that an 80,000 Btu/h gas furnance will have the combustion air
supplied from a mechanical air supply system outdoor source, the
combustion in shall be at least ______ cubic feet per minute of ventilation. - -
28

- Federal unemployment tax act (FUTA) rate is at 6%, which applies to the
first _______ you pay to each employee as wages during the year. - -$7,000

Información del documento

Estudio
Subido en
19 de enero de 2025
Número de páginas
2
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
4
Seguidores
0
Artículos
789
Última venta
6 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes