Which area is the first to accept responsibility for all supplies in the

facility? Receiving

Which type of inventory distribution system requires the use of a pre-determined inventory list?

Par Level

Just-in-time distribution systems are also known as

Stockless Distribution

Ordering the optimum quantity of an item based on historical data is known

as Economical Order Quantity

Which of the following are elements of a distribution

system?patient charging, storage, and receiving

The most efficient distribution system is the

Total exchange cart

The computerized locked supply system is a variation of

the Par Level

Which distribution system requires the using department to be responsible for maintaing

inventory levels? Demand

An ongoing inventory management system is known as a

Perpetual Inventory System

,In which distribution system are requisition filled and delivered as they are

received? Demand

Inventory performance" (a rough indication of the effectiveness of the inventory system) is evaluated by

percent of back order, availability of critical items, and inventory turnover

Which of the following is the MOST efficient and cost-effective method for inventory control in the SPD
ordering and data generation?

Computerized Inventory Control System

The temperature in the sterile storage are should not

exceed75º F (24º C)

Shelving in the sterile storage area must be kept how far from the outside

walls? 2 inches

The thickness of a sterility maintenance cover

should be2 to 3 mils

The minimum number of air exchanges per hour in the sterile storage area

should be4

The relative humidity in the sterile storage area should not exceed

70%

Approximately how much space should be left between and item and the inside edges of a

peel pouch? 1 inch

What is the maximum size and weight of a textile

pack?12" x 12 x 20" 12 pounds

Which of the following packaging materials is acceptable for low-temperature gas plasma and ozone
sterilization

Tyvek

Basin sets should be prepared for sterilization

with an absorbent material between each basin

Tamper-evident seal on rigid containers

,include

, latches and locks

What is the acceptable temperature range for the prep and

packaging area? 68º F-73º F (20º-23º C)

The preparation and packaging area must have an air exchange

rate of10 per hr

If a non-perforated tray is used for the sterilization of instrument sets, it must

be Tilted on the sterilizer rack

The ideal humidity level in the preparation and packing area

should be50%

For sterilization, rigid containers must be

placed flat

Which of the following packaging materials is acceptable for steam

sterilization? Non-woven wraps

Re-passivation of an instrument can be achieved by

routine lubrication

What is the most difficult part of a hemostat to

clean? box lock

Which of the following lubricants is recommended for use on

surgical instruments?petroleum-based

What type of finish on a surgical instrument is used for laser procedures?

ebonized

What is the final stage in manufacturing a surgical grade

instrument?passivation

Which series of stainless steel is used is to manufacture malleable

retractors? 300

The weakest part of the instrument is/are the

Información del documento

Subido en
27 de noviembre de 2024
Número de páginas
53
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$27.39

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BestSolutions
4.8
(53)
Vendido
173
Seguidores
135
Artículos
2995
Última venta
1 año hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes