Mri physics final Exam with Verified
Solutions
which pulse sequence below reduces magnetic susceptibility artifact Correct Ans-spin Echo
pulse sequence



cardiac gating is used to eliminate which artifact Correct Ans-phase miss-mapping




gradient moment nulling is most effective on Correct Ans-slow, regular flow




antispasmodic agents are used to reduce what kind of motion Correct Ans-bowel motion



when applying a preset pulse, all nuclides get flipped to the 90° transverse plane in the SAT
band. The flowing nuclei (blood) that then moves into the slice and receives the excitation pulse
are moved into Correct Ans-180° fully saturated




out of phase artifact is also called Correct Ans-chemical Mis registration




to prevent anti-aliasing along the frequency access Correct Ans-most Systems Incorporated to
filter out noise when enlarging the fov

,when using respiratory compensation, the system will perform the shallow phase encoding
gradient slopes to fill the central lines of K space when the chest wall movement is at a minimum
Correct Ans-true




what device is used in respiratory compensation Correct Ans-Bellows wrapped around the
chest



phase mismapping is caused by Correct Ans-Anatomy moving along the phase encoding
gradient during the pulse sequence



total elimination of face mapping according to the text, is impossible unless Correct Ans-you
are Imaging a cadaver



pre saturation pulses are only effective Correct Ans-if applied to tissue




this artifact is caused by undersampling by the frequency encoding gradient Correct Ans-
frequency wrap



this artifact is caused by nuclei being given the same phase outside of the fov as nuclei within the
fov Correct Ans-phase wrap




undersampling and its artifact refers to Correct Ans-the Nyquist theorem

,which remedy below is a remedy for decreasing the effects of the magnetic susceptibility artifact
Correct Ans-decreasing the TE



to prevent cross excitation, what percentage of your slice thickness should be used when you
work on a computer system that does not square off your RF pulse Correct Ans-30%



to prevent cross excitation what percentage of your slice thickness should be used when you
work on a computer system that does square off your RF pulse Correct Ans-10%




which artifact can be reduced by exciting alternate slices in a given volume Correct Ans-cross
excitation artifact



this particular remedy is used to reduce cross excitation even further than using alternate slice
excitation what is it called Correct Ans-interleaving and concatenation



one way to eliminate this artifact is to reposition the patient so they are not at a 55 degree angle
to be subscript zero Correct Ans-magic angle




which artifact below occurs only in the phase Direction Correct Ans-phase mis-mapping




which artifact below can occur in either the frequency or the phase Direction Correct Ans-
shading

, This substance has a very high positive susceptibility when exposed to a magnetic field
Correct Ans-Ferromagnetic




Gadolinium, which contains gadolinium chelates, is a member of which group Correct Ans-
Paramagnetic



What is the purpose of cryogens Correct Ans-to super cool the coils of the wire in a
superconducting magnet



Why is active shielding more commonly used than passive shielding Correct Ans--not as
heavy

-more effective

-less costly

all of the above



Current standards restrict magnetic fringe field to Correct Ans-5G




Which answer below describes how passive shielding is accomplished Correct Ans-surrounds
the magnet room with steel plates



What is the temperature of the wires of superconducting electromagnets when they exhibit zero
resistance Correct Ans-4K

Información del documento

Subido en
26 de noviembre de 2024
Número de páginas
54
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$16.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
KeithAndrews
3.0
(28)
Vendido
135
Seguidores
5
Artículos
15485
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes