Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 18 páginas
Examen

OIL BURNER LICENSE EXAM AND PRACTICE EXAM NEWEST ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT DETAILED ANSWER2

Document preview thumbnail
Vista previa 3 fuera de 18 páginas

OIL BURNER LICENSE EXAM AND PRACTICE EXAM NEWEST ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT DETAILED ANSWER2

Vista previa del contenido

OIL BURNER LICENSE EXAM AND PRACTICE
EXAM NEWEST ACTUAL EXAM COMPLETE 250
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+


What is the first thing a tech should do when arriving at a no combustion call? -
ANSWER Ask how many times the customer reset the unit.

What is the best long term solution for preventing a clogged nozzle? - ANSWER -
Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.

Hot water and steam valves are interchangeable. - ANSWER False

When in the presence of a flame, a cad cell normally reads.. - ANSWER 300-1000
ohms

If a pump is used to bring oil to a level higher than the tank, an oil safety valve is
required. - ANSWER True

On a call where a hydronic heat system is putting out too much heat on the stack, the
issue may be.. - ANSWER -Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.

A high CO2 reading is caused by.. - ANSWER Incomplete combustion

An often overlooked cause of a high CO2 reading is.. - ANSWER Not enough
combustion air in the equipment room.

When multiple pumps are wired together in a heating system, they should be wired in.. -
ANSWER parallel

In a series circuit.. - ANSWER Current has one path.

When 2 burners are connected to the same chimney.. - ANSWER Sufficient draft must
be obtained to operate both units.

The ignition transformer is located.. - ANSWER In the primary control.

,When safeties are wired in series one safety will affect the operation of the others. -
ANSWER True

A stack switch is no longer allowed to be installed or replaced because.. - ANSWER It's
safety cutout time is higher than what is now required.

What is a power venter and what does it do? - ANSWER An electrical device that sends
fluid gases into the chimney connector.

A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent
opening for combustion air? - ANSWER 140"

The difference between an adjustable flame retention burner and a fixed flame retention
burner is? - ANSWER Air inlets can be adjusted

Ignitor position can be adjusted

Fuel can be adjusted

Oil tank design, construction, installation and testing shall be in accordance with.. -
ANSWER 527 CMR 9.0

Heat is a form of.. - ANSWER Energy

If a burner is operational but the circulator pump isn't running.. - ANSWER The pump
relay is not working correctly

A method of dealing with low viscosity/cold temps with #2 oil? - ANSWER Increase
pump pressure/ decrease nozzle size

What is needed at the outlet of an oil tank? - ANSWER Thermal safety valve

Where do you obtain an installation permit for oil burners? - ANSWER Fire Dept

How many Btu's approximately in 1 gal of #2 fuel oil? - ANSWER 140,000 btu's

Solid state ignition is superior to spark because - ANSWER It is not affected by reduced
voltage

What is an installation? - ANSWER The complete setting in place, ready for operation,
of an oil burner appliance together with its accessories and equipment.

How far must a power vent terminate from an opening or window? - ANSWER 4'

A pump in a one pipe system that is full of air can be self purged. - ANSWER False

, List the minimum size of an oil supply line. - ANSWER 3/8"

A material with electrons so loose it allows voltage to pass with little or no resistance.. -
ANSWER Is a conductor

If a high limit goes off, what does a low water switch do? - ANSWER Maintains water
temperature

What is flashpoint an indicator of? - ANSWER Minimum temperature oil will ignite but
not continue to burn.

What travels on the inside of the wire? - ANSWER Volts

What does readily accessible mean pertaining to oil burning equipment? - ANSWER
Capable of being reached easily and quickly for operation, maintenance or inspection.

What is the minimum vent pipe on an oil tank? - ANSWER 1 1/4"

What causes corrosion on a flue pipe? - ANSWER When the flue pipe is operating
below the dew point temperature.

What are the methods to prevent oil waxing? - ANSWER Put additives in the fuel.

Add an oil line heater.

Cut with #1 fuel or kerosene.

What is the maximum tank size allowed inside unenclosed? - ANSWER 660 gal

What is the purpose of a delayed oil valve? - ANSWER Allows time for the oil pump to
get up to speed.

Delays oil flow to the nozzle.

On a call where a hydronic heat system is putting out too much heat, the issue could
be? - ANSWER A shorted out thermostat.

When measuring a cad cell with the burner running and the ff terminals jumped out,
what should the cad cell reading be? - ANSWER 1600 ohms

What are the possible causes of soot at or near the power venter? - ANSWER
Incomplete combustion

What is a possible side effect of air in a nozzle line? - ANSWER Soot

What is the cause if the cad cell is tripped on safety? - ANSWER Dirty cad cell

Información del documento

Subido en
19 de noviembre de 2024
Número de páginas
18
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
phinta004
4.7
(182)
Vendido
20
Seguidores
2
Artículos
982
Última venta
2 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes