• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 79 páginas
Examen

IEC 2A

Document preview thumbnail
Vista previa 4 fuera de 79 páginas

Exam of 79 pages for the course IEC 2A at IEC 2A (IEC 2A)

Vista previa del contenido

IEC 2A QUESTIONS & VERIFIED
RATIONALIZED ANSWERS 100%
GUARANTEE PASS

electrode system (earth) is to ___.

I. cause the quick operation of OCPDs

II.keep all metal parts at the same voltage

III. limit voltage surges - e. II & III only



A metal enclosure surrounding electrically operated equipment ___.

a. is required to be grounded

b. protects the equipment from physical damage

c. provides protection for people against accidental contact with live parts - d. all of these



The amount of current that flows in any circuit is determined by the voltage and resistance of the circuit.

Select one:

a. True

b. False - a. True



___ is defined as case or housing of apparatus, or the fence or walls surrounding an installation to
prevent personnel from accidentally contacting energized parts or to protect the equipment from
physical damage.

Select one:

a. Inaccessible

b. Guarded

c. Isolated

d. Enclosure - : Enclosure

,The circuit installed in a run of PVC conduit requires a 6 AWG equipment grounding conductor. However,
a 12 AWG was installed instead. Using the 12 instead of the 6 AWG wire will ___ the amount of time
required for a circuit breaker to open when a ground fault occurs.

Select one:

a. increase

b. decrease

c. have no effect on - increase



Providing a low impedance ground return path ___ when a ground-fault occurs.

Select one:

a. has no effect on the circuit current

b. permits a high current to flow

c. limits the amount of current to a small amount - permits a high current to flow



In a run of conduit, when couplings and connectors are loose this will ___ the amount of time required
for a circuit breaker to open when a short-circuit occurs.

Select one:

a. have no effect on

b. increase

c. decrease - have no effect on



The plans indicate that you should install a 300-amp branch circuit in Schedule 40 PVC with a 4 AWG
equipment grounding conductor. However, you did not have any 4 AWG wire so you pulled in 10 AWG
instead. With a load connected, the normal circuit current will be ___ with the 10 AWG EGC (compared
to using a 4 AWG EGC).

Select one:

a. the same

b. less

c. greater - the same

,The primary purpose of grounding metal equipment enclosures and metal raceways to the grounding
electrode system (earth) is to ___.I. cause the quick operation of OCPDsII. keep all metal parts at the
same voltageIII. limit voltage surges

Select one:

a. I only

b. I, II & III

c. I & III only

d. I & II only

e. II & III only - II & III only



A metal enclosure surrounding electrically operated equipment ___.

Select one:

a. is required to be grounded

b. protects the equipment from physical damage

c. provides protection for people against accidental contact with live parts

d. all of these - all of these



Refer to Figure 205.15. The flex used between the breaker enclosure and the motor contains three 350
kcmil conductors. The minimum size of the EGC between the 700-A breaker and the motor is ___.

Select one:

a. 350 kcmil

b. 3/0 AWG

c. 2 AWG

d. 1/0 AWG

e. none of these - 1/0 AWG



Three 4/0 AWG conductors are installed in the flex between the breaker enclosure, containing a 500-A
breaker, and the motor. The smallest EGC that can be installed in the flex shown in Figure 205.15 is ___.

Select one:

a. 2/0 AWG

, b. 4/0 AWG

c. 1 AWG

d. 3 AWG

e. none of these - none of these



The plans indicate that you should install a 200-Amp branch circuit in Schedule 40 PVC with a 6 AWG
equipment grounding conductor. However you did not have any 6 AWG wire so you pulled in 12 AWG
instead. Compared to the correct circuit (with the 6 AWG EGC) your circuit will take ___ time for the
circuit breaker to open when a ground fault occurs.

Select one:

a. the same amount of

b. less

c. more - : more



Refer to Figure 205.11. The 200-A safety switch contains 125-amp fuses. The raceways used between the
switch and the 3Ø motor contain three 2 AWG conductors. The minimum size of the EGC between the
safety switch and the motor is ___ AWG.

Select one:

a. 4

b. 6

c. 8

d. 2

e. 3 - 6



Refer to Figure 205.14. Load 1 is supplied from a 100 A circuit breaker with 3 AWG conductors. Load 2 is
supplied from a 350-Amp breaker with 500 kcmil conductors. Both loads are 3-ph, 3-wire. The smallest
grounding conductor that can be installed between the pull box and Load 1 is ___ AWG.

Select one:

a. 6

b. 2

c. 4

Información del documento

Subido en
15 de noviembre de 2024
Número de páginas
79
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$9.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
edunurse
3.6
(19)
Vendido
156
Seguidores
13
Artículos
6803
Última venta
3 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes